HGD-3000 Hydrogen Gas / Smoke Detector with Intrusion Alarm
1 / 1ページ

カタログの抜粋

HGD-3000 Hydrogen Gas / Smoke Detector with Intrusion Alarm - 1

To Order Call Toll Free: HGD-3000 Hydrogen Gas / Smoke Detector with Intrusion AlarmModel # HGD-3000 Gas Detection GD~SERIES 29 Hydrogen Gas Detection The HGD-3000 Hydrogen Gas and Smoke Detector with optional Silent Intrusion Alarm is designed for unattended battery installations or remote shelters containing gassing lead acid batteries and charging systems. The HGD-3000 will turn on an exhaust fan when hydrogen gas levels reach 1% and will alarm at 2%. This alarm consists of a local 80db horn, a flashing red LED, and a dry contact switch closure for remote alarming. Smoke Detection The photoelectric smoke sensor detects minute combustion products from smoldering wire insulation, battery cases, and other material. When smoke is detected, a distinctive alarm is emitted from the 80db horn and a separate dry contact switch is activated. At this time, the exhaust fan is inhibited in order to deny the fire increased oxygen from outside air. Temperature, Loss of Power, & Intrusion During normal operation and in the absence of an alarm condition, an internal thermostat will turn on the exhaust fan at a preset temperature to reduce heat buildup in the room. Loss of power to the unit will also generate a dry contact alarm. Additionally, an optional infrared intrusion alarm will trigger a silent dry contact switch. Features • Automatic Operation and Continuous 24/7 Monitoring • Highly sensitive and stable solid state hydrogen sensor • Sensitive photoelectric smoke detector module • Internal thermostat for automatic exhaust fan control at 40°C (104°F) with ±5° adjustable range • Save insurance costs - reduce insurance premiums when placed in battery charging rooms Technical Specifications Detection: Alarms: Relay Connections Mounting: Operating Environment: Power Requirements: Compliance: Dimensions: Hydrogen Gas, Smoke, Temperature, Intrusion 10A Relay for Exhaust Fan, 1A Relay for Loss of Power, 1A Relay for Smoke Alarm, 1A Relay for Intrusion, 1A Relay for 2% H2 Concentration RJ45, Punch-Down Block (4) 4.5 mm (3/16 in) screws Temperature: -10 - 40 °C (14 - 104 °F) Standard: 85 - 265 VAC, 50/60 Hz Optional: 17 - 60 VDC IEEE Standard 450; National Protection Agency (NFPA) Article 64; NFPA 2: Hydrogen Technologies Code; Uniform Building Code (UBC) Section 6400; National Electric Code (NEC) Section 480.9 (A); NEC 501.125 (B); NEC 501.105 (1)-3 - use in Class 1 Division 2 Group B. 178 x 120 x 55 mm (7 x 4.75 x 2.5 in) Applications • Utilities and Power Plants • UPS Power Systems • Fuel Cell Test Stations • Nuclear Waste Reforming • Hydrogen Refueling Stations • Fire Department • Battery Suppliers • Battery Charging Rooms • Motive Power • Golf Cart • User Manual • Optional: Silent-Alarm Add-on • Optional: Breakout box for easy-access control • Optional: Junction Box Ordering Information

カタログの1ページ目を開く

Eagle Eye Power Solutionsのすべてのカタログと技術パンフレット

  1. NERC PRC-005-02

    2 ページ

  2. DCPS-Shelf-6KW

    2 ページ

  3. DCPS-Shelf-9KW

    1 ページ

  4. SC-1000

    2 ページ

  5. SC-1500

    2 ページ

  6. SC-2000

    2 ページ

  7. RM-48-2K

    2 ページ

  8. RM-48-3K

    2 ページ

  9. RM-48-KA

    1 ページ

  10. MIS-1000

    3 ページ

  11. MIS-2000-series

    3 ページ

  12. MIS-3000-series

    3 ページ

  13. MIS-4000-series

    3 ページ

  14. MIS-5000-series

    3 ページ

  15. SIS-1000-series

    2 ページ

  16. ENC-1000 Enclosure

    1 ページ

  17. ENC-2000

    1 ページ

  18. BMS-Series Catalog

    19 ページ

  19. LB-AC-Digital

    1 ページ

  20. BTM-Series

    1 ページ

  21. BQMS

    2 ページ

カタログアーカイブ

  1. HGD-3000

    1 ページ

  2. DC Load Bank

    3 ページ

  3. LB-1000

    1 ページ

  4. SCR-SCRF

    1 ページ

  5. AT10.1 - AT30

    1 ページ

  6. SG-100M

    1 ページ

  7. SG-1000

    1 ページ

  8. SG-Ultra Max

    1 ページ

  9. DC SLB-Series

    3 ページ