ENGINEERING TOMORROW Catalogue OptymaTM Condensing Units Lightweight and compact solution R22 - R134a - R404A - R507, 60 Hz OPTYMA™ http://cc.danfoss.com DANFOSS CONDENSING UNITS
カタログの1ページ目を開く
Designation system Version - Product configuration Note The unit may only be operated with the types of refrigerants stated in the capacity tables. * Not available for units equipped with scroll compressors. ** Only for units equipped with scroll compressors.
カタログの3ページ目を開く
High-pressure cartdrige Micro-channel type condenser Filter drier Hermetic reciprocating compressor Rotolock valve* Metal electrical box with contactor Low-pressure switch Receiver Sight glass Note: *Not available for units equipped with scroll compressors. D40 version High-pressure cartdrige Receiver Filter drier Outdoor housing Reciprocating or scroll compressor Metal electrical box with contactor Suction accumulator Sight glass Low-pressure switch
カタログの4ページ目を開く
Optimal refrigeration solution Lighter condensing unit R22 Reduced refrigerant charge Condensing units with micro-channel condensers use up to 30% less refrigerant charge than those equipped with fin and tube type condensers, thus streamlining the installer's workload. Faster installation New condensing units equipped with micro-channel condensers are up to 15 kg lighter than conventional ones. Refrigerant charging time is significantly reduced since less amount of refrigerant is used. Units feature suction and discharge valves allowing fast and easy maintenance. Refrigerant evacuation time...
カタログの5ページ目を開く
Main product features Crankcase heater Micro-channel condenser Rotolock valve • The crankcase heater reduces by 23.5% the risk of the compressor failing under flooded start-up conditions, thus extending the operating life of the condensing unit. • As the micro-channel condenser has a reduced internal volume, it uses a smaller amount of refrigerant charge and is more efficient, hence reducing refrigerant evacuation and charging time even further. Cleaning and maintenance are also easier and faster. • The presence of Rotolock valves on the condensing unit suction and discharge lines allows...
カタログの6ページ目を開く
Cooling Capacity ranges and application limits Rated capacity ranges (Btu/h)* Units with reciprocating compressors Units with scroll compressors OP-H units... with R22 Evaporating temperature for OP-H units...: -10°C. Evaporating temperature for OP-L units...: -25°C Application limits (evaporating temperature in °C) OP-H units... with R22 Units with reciprocating compressors Units with scroll compressors OP-H units... with R22 1) Calculate the cooling capacity required for the application. 2) Select your preferred type of coolant and then a unit with sufficient capacity to suit the...
カタログの7ページ目を開く
R22 MBP/HBP - Reciprocating Cooling capacity [Btu/h] at evaporating temperature 20°C Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply The consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの8ページ目を開く
Catalogue R22 MBP/HBP - Scroll Cl_Q 3 3 CO V) Electrical codes: Model Cooling capacity [Btu/h] at evaporating temperature N - Compressor 230 V/1-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz Q - Compressor 230 V/3-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz R - Compressor 460 V/3-ph/60 Hz , fan(s) 460 V/1-ph/60 Hz Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply The consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの10ページ目を開く
Catalogue R22 MBP/HBP - Scroll Model
カタログの11ページ目を開く
R134a MBP/HBP - Reciprocating Cooling capacity [Btu/h] at evaporating temperature -10°C Electrical codes: N - compressor 230 V/1-ph/60 Hz, fan(s) 230 V/1-ph/60 Hz Q - compressor 230 V/3-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz R - compressor 460 V/3-ph/60 Hz, fan(s) 460 V/1-ph/60 Hz Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply The consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの12ページ目を開く
Catalogue R134a MBP/HBP - Reciprocating
カタログの13ページ目を開く
Catalogue R134a MBP/HBP - Scroll Model Cooling capacity [Btu/h] at evaporating temperature Electrical codes: N - compressor 230 V/1-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz Q - compressor 230 V/3-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz R - compressor 460 V/3-ph/60 Hz , fan(s) 460 V/1-ph/60 Hz Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply The consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの14ページ目を開く
Catalogue R134a MBP/HBP - Scroll Model
カタログの15ページ目を開く
Electrical codes: N - compressor 230 V/1-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz Q - compressor 230 V/3-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz R - compressor 460 V/3-ph/60 Hz , fan(s) 460 V/1-ph/60 Hz Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply Power consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの16ページ目を開く
Catalogue R404A/R507 MBP/HBP - Reciprocating Model
カタログの17ページ目を開く
oo ro Ol % .E <U -rr -£ § <u u Cl _Q 3 3 CO W Electrical codes: N - compressor 230 V/1-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz Q - compressor 230 V/3-ph/60 Hz , fan(s) 230 V/1-ph/60 Hz R - compressor 460 V/3-ph/60 Hz , fan(s) 460 V/1-ph/60 Hz Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply Power consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの18ページ目を開く
Catalogue R404A/R507 MBP/HBP - Scroll Model
カタログの19ページ目を開く
Ambient temperature N - compressor 230 V/1-ph/60 Hz, fan(s) 230 V/1-ph/60 Hz Q - compressor 230 V/3-ph/60 Hz, fan(s) 230 V/1-ph/60 Hz R - compressor 460 V/3-ph/60 Hz, fan(s) 460 V/1-ph/60 Hz Cooling capacity for three-phase models shown. For single-phase models a difference of +/- 1% shall apply Power consumption values shown relate to an ambient temperature in the equipment room of 32°C. Detailed settings for versions D32 and D40 can be found on page 03.
カタログの20ページ目を開くDanfoss Industrial Automationのすべてのカタログと技術パンフレット
-
Pressure switch Type RT
21 ページ
-
Pressure switch RT
17 ページ
-
Wind Power
8 ページ
-
Danfoss Link™
14 ページ
-
Electric Heating
40 ページ
-
Hydronic Specialties
48 ページ
-
Optyma™ Semi-Hermetic
22 ページ
-
Optyma™
60 ページ
-
Supermarkets
28 ページ
-
HGM-PGM Gas detector
4 ページ
-
Clean Grid Solutions
44 ページ
-
Type EV210A
10 ページ
-
Marine applications
12 ページ
-
Switches overview
2 ページ
カタログアーカイブ
-
Core Products Catalogue
171 ページ