video corpo

synchro compact hmi core standard wiring schematics revision a 19-05-2019
1 / 18ページ

{{requestButtons}}

カタログの抜粋

synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 4

SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Module Rear / Core view PAGE 04 ◄ ► 03 05

カタログの4ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 5

CORE VERSION MOUNTING SCREWS DIMENSIONS Created: 09/05/2019 SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Dimensions / Panel cut PAGE

カタログの5ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 6

SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Single line diagram PAGE 06 ◄ ► 05 07

カタログの6ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 7

SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS * Note1: Shall voltage transformers be required, refer to technical documentation PAGE Voltages and currents sensing 07 06 ►

カタログの7ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 8

To inputs / outputs circuitry Module power supply 7...38vVdc * Note 1 COMPACT SYNCHRO * Note1: Example given with use of a 24Vdc battery charger, but applies identically with 12Vdc PAGE SYNCHRO COMPACT HMI / CORE FIRST RELEASE STANDARD WIRING SCHEMATICS Power supply and shield connection 07

カタログの8ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 9

Breaker potion / Synch request / Spare ( Spare Configurable digital inputs CD O CD O 9 * Note 1: Default setting, can be adjusted via PC software as desired SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Digital inputs PAGE 09 ◄ ► 08 10

カタログの9ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 10

Module +Vcc SENSOR CONNECTION EXAMPLES Module +Vcc Configurable analog inputs * Note 1 COMPACT SYNCHRO * Note1: Analog inputs can be used with resistive sensors (max. range 0-500 Ohms), with external 20mA current transducers fitted with a 30-ohm 1/4 Watt resistor or as additional digital inputs ** Note2: Ensure engine body and 0Vcc are connected in case of use of a single-wire sensor *** Note3: The common analog input terminal must have a direct connection to the –Batt terminal of the controller PAGE SYNCHRO COMPACT HMI / CORE FIRST RELEASE STANDARD WIRING SCHEMATICS

カタログの10ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 11

COMPACT SYNCHRO Configurable digital outputs J1 * Note1: Maximum output current is 1.8 Amps PAGE SYNCHRO COMPACT HMI / CORE FIRST RELEASE STANDARD WIRING SCHEMATICS

カタログの11ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 12

SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Relay outputs PAGE 12 ◄ ► 11 13

カタログの12ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 13

SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS * Note1: Refer to the engine technical sheet to set the number of teeth PAGE

カタログの13ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 14

COMPACT SYNCHRO Voltage control output Speed control output SPEED REGULATOR VOLTAGE REGULATOR * Note1: Settings vary upon the type of regulator used. Refer to the technical sheet for more information PAGE SYNCHRO COMPACT HMI / CORE FIRST RELEASE STANDARD WIRING SCHEMATICS Speed & voltage control 13

カタログの14ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 15

COMPACT SYNCHRO TO OTHER MODULES ** Note 2 * Notel: Embedded 120-ohm resistance to be bridged to CAN H terminal on first and last bus module only ** Note2: CAN 1 is dedicated to inter-module communication. CAN options are available on CAN2 SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS

カタログの15ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 16

COMPACT SYNCHRO Distance between node and module should not exceed 30 centimeters Notel: Bus end 120-ohm resistor to be placed between CAN L and CAN H terminal on last equipment only SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS

カタログの16ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 17

SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Engine control PAGE

カタログの17ページ目を開く
synchro compact hmi core standard wiring schematics revision a 19-05-2019 - 18

SPARE INFORMATION SPARE INFORMATION SPARE INFORMATION SPARE INFORMATION SPARE INFORMATION SYNCHRO COMPACT HMI / CORE STANDARD WIRING SCHEMATICS Digital output terminals PAGE 18 ◄ ► 17

カタログの18ページ目を開く

CRE TECHNOLOGYのすべてのカタログと技術パンフレット

  1. gensys 2.0 range

    4 ページ

  2. SCR 2.0

    2 ページ

  3. BTB COMPACT

    4 ページ

  4. I4GEN.10

    2 ページ

  5. I4GEN suite

    2 ページ

  6. DC/DC Converters

    2 ページ

カタログアーカイブ

  1. ICGEN2.0

    55 ページ

  2. Battery chargers

    24 ページ

  3. C2S

    16 ページ

  4. GENSYS 2.0 CORE

    4 ページ

  5. BP range

    2 ページ

  6. i4GEN

    2 ページ

  7. TRAININGS SESSIONS

    4 ページ

  8. BATTERY CHARGERS

    4 ページ

  9. avrcompact

    2 ページ

  10. MARINE SOLUTIONS

    4 ページ

  11. Synchro Compact

    144 ページ

  12. COMPACT RANGE

    4 ページ