4F ** 0EX series
1 / 28ページ

{{requestButtons}}

カタログの抜粋

4F ** 0EX series - 1

Compliant with Internationally Consistent Explosion Proof Guidelines, Explosion proof capability Ex d IIB T4 Pilot-operated explosion proof 5 port valve 4F**0EX series EXPLOSION PROOF 5 PORT PILOT OPERATED VALVE Safely usable in hazardous atmosphere Compliant with IEC standard Compliant with Internationally Consistent Explosion-Proof Guidelines Pressure-resistant explosion-proof construction d Group II B Temperature class T4 Model inspection No. for model test No.TC20523 Usable outdoors Protection construction IP65 (dust-proof, jet-proof) Extended range of cable diameter selection ø7.5 to 13.5 lined up Obtained South Korea explosion-proof certification (KOSHA), Taiwan explosion-proof certification (ITRI)

カタログの1ページ目を開く
4F ** 0EX series - 2

Flow characteristics Series appearance No. of solenoid position JIS symbol Note 1 : Effective sectional area S and sonic conductance C are converted as S ^ 5.0 * C.

カタログの2ページ目を開く
4F ** 0EX series - 4

Discrete valve Pilot-operated explosion proof 5 port pneumatic valve Proof pressure explosion-proof structure Ex d IIB T4 (group IIB/temperature grade T4) Japan certified model inspection No. #TC20523 South Korea certified model inspection No. 15-AV4BO-0389 Taiwan certified model inspection No. Construction/electric (2015) #00216 Compatible cylinder bore size: 063 to 0250 Common specifications Electrical specifications (Ci) (C2) Note i: Ambient temperature refers to the temperature for storage and installation, and differs from fluid temperature, which applies during operation. Note i:...

カタログの4ページ目を開く
4F ** 0EX series - 5

Flow characteristics Note 1 : Effective sectional area S and sonic conductance C are converted as S ^ 5.0 * C. Rechargeable battery specifications The airflow passage and the material of the sliding sections are restricted to allow the unit to be used in the rechargeable battery manufacturing process. Contact CKD for types.

カタログの5ページ目を開く
4F ** 0EX series - 6

Discrete valve How to order • Explosion proof 5 port pneumatic valve [BSolenoid position > Explosion-proof certification authority | Symbol [CPort size A Note on model No. selection Note 1: For explosion-proof certification authority “KR” or “TW” “9” will be 98.5 to 99.5. Also, “13” cannot be selected. Note 2: Explosion-proof certification voltage 220 VDC outside of listed voltages will be handled as a special order. Note 3: When you order a coil, please order it as a pilot actuator assembly. Note 4: Contact CKD for using the unit for vacuum pressurization of an external pilot (K),...

カタログの6ページ目を開く
4F ** 0EX series - 7

4F3*0EX Series Discrete valve; Body piping Internal structure and parts list 4F310EX

カタログの7ページ目を開く
4F ** 0EX series - 8

Discrete valve; Sub-plate piping Internal structure and parts list 4F|2OEX • 2-position double solenoid 4F63OEX, 4F54OEX 4Ff5OEX • 3-position All ports closed A/B/R connection P/A/B connection Main parts list Repair parts list

カタログの8ページ目を開く
4F ** 0EX series - 9

4F3**0EX Series Discrete valve; Body piping ● L-type mounting leg (P) for single solenoid Solenoid valve 3-ø4.5 Solenoid valve Installation hole ● Position change of manual operating device (R) 51 Manual operating device R adaptor CKD

カタログの9ページ目を開く
4F ** 0EX series - 10

Discrete valve; Sub-plate piping Manual override 2-ø13 counter bore Depth 9 2-M8 depth 11 (Pilot hole ø7) 2-ø13 counter bore Depth 9 2-M8 depth 11 (Pilot hole ø7) 2-ø13 counter bore Depth 9 2-M8 depth 11 (Pilot hole ø7) Solenoid valve 2-ø8.5 Solenoid valve Installation hole

カタログの10ページ目を開く
4F ** 0EX series - 11

Discrete valve; Sub-plate piping 2-M8 depth 15 (Pilot hole ø7) 2-ø13 counter bore Depth 9 2-ø13 counter bore Depth 9 2-M8 depth 15 (Pilot hole ø7) 8-R3.3 Installation hole 2-ø8.5 Solenoid valve Installation hole 2-ø13 counter bore Depth 9 2-MA depth 15 (Pilot hole ø7)

カタログの11ページ目を開く
4F ** 0EX series - 12

Discrete valve; Sub-plate piping Manual override Manual override 2-ø16 counter bore Depth 15 2-M10 depth 15 (Pilot hole ø9) 2-M10 depth 15 (Pilot hole ø9) 2-ø16 counter bore Depth 15 8-R3.5 Installation hole 2-ø11 Solenoid valve Installation hole Manual override 2-M10 depth 15 (Pilot hole ø9) 2-ø16 counter bore Depth 15 Solenoid valve

カタログの12ページ目を開く
4F ** 0EX series - 13

Discrete valve; Sub-plate piping Manual override Manual override 2-ø20 counter bore Depth 16.5 2-M12 depth 23 (Pilot hole ø10.3) Manual override 2-ø14 Solenoid valve Installation hole 2-ø20 counter bore Depth 16.5 2-M12 depth 23 (Pilot hole ø10.3) 2-ø20 counter bore Depth 16.5 2-M12 depth 23 (Pilot hole ø10.3)

カタログの13ページ目を開く
4F ** 0EX series - 14

Individual wiring manifold Pilot-operated explosion proof 5 port pneumatic valve Proof pressure explosion-proof structure Ex d IIB T4 (group IIB/temperature grade T4) Japan certified model inspection No. #TC20523 South Korea certified model inspection No. 15-AV4BO-0389 Taiwan certified model inspection No. Construction/electric (2015) #00216 Compatible cylinder bore size: 063 to 0250 Common specifications Electrical specifications Note i: Ambient temperature refers to the temperature for storage and installation, and differs from fluid temperature, which applies during operation. Note i:...

カタログの14ページ目を開く
4F ** 0EX series - 15

Flow characteristics Note 1 : Effective sectional area S and sonic conductance C are converted as S ^ 5.0 * C. M4F**0EX Individual wiring manifold

カタログの15ページ目を開く
4F ** 0EX series - 16

Series Individual wiring manifold How to order Discrete solenoid valve for manifold (4F3) (^4F3^d) 0 EX(08-G(J0-(®' Discrete solenoid valve for manifold (4F4 to 7) C4F4^d> 9 EX-@-G@- O Enter the number of solenoid valves V°ltag»J Expl°sion-pr(X)f used in the case of mix manifold. certification authority (Refer to page 16 for examples of the description.)

カタログの16ページ目を開く
4F ** 0EX series - 17

M4F**0EX Series Individual wiring manifold How to order masking plate kit M4F3 A Port size Symbol Descriptions Model No. Port size * asket attached (M4F3) G Gasket and set screw attached (M4F4 to M4F7) * efer to the previous page for R other model indications. How to indicate mix manifold model numbers ①Indicate the quantity for each function (changeover position class) at the end of the model. Functions and symbols are indicated below. e.g.: 2-position single solenoid -> S1 Symbol Function (Solenoid position) S1 ② Enter the function (solenoid position) and layout position in the remark...

カタログの17ページ目を開く

CKDのすべてのカタログと技術パンフレット

  1. MN4GA / 4GB

    140 ページ

  2. MV3QR

    16 ページ

  3. PV5G/PV5/GMF/PV5S-0

    76 ページ

  4. 4G unit valve

    4 ページ

  5. SCP*3 Series

    60 ページ

  6. SCS2 series

    56 ページ

  7. Guided cylinder STM

    24 ページ

  8. Compact cylinder SSD

    221 ページ

  9. Compact cylinder SSD2

    278 ページ

  10. Tie rod cylinder SCG

    87 ページ

  11. LMD series

    15 ページ

  12. KBZ series

    64 ページ

  13. AGD21R-A series

    4 ページ

  14. WXU series

    32 ページ

  15. AX6000M

    24 ページ

  16. SCS-G Series

    2 ページ

  17. CMK2 SR

    7 ページ

  18. CMK2-T Series

    1 ページ

  19. SCPS2-V Series

    4 ページ

  20. SCPD2-*C Series

    1 ページ

  21. SCPD2-K Series

    3 ページ

  22. SCPS2-MSeries

    4 ページ

  23. SCPD2-F Series

    2 ページ

  24. SCPD2 Serie

    3 ページ

  25. SCPD2 Series

    2 ページ

  26. SCPS Series

    1 ページ

  27. SCM Series

    2 ページ

  28. GHV series

    4 ページ

  29. Pneumatic valves

    8 ページ

  30. Pneumatic cylinders

    12 ページ

カタログアーカイブ