PIN LOAD CELL TYPE PR
1 / 3ページ

カタログの抜粋

PIN LOAD CELL TYPE PR - 1

CELMI s.r.l. Largo Brugnatelli 13/16 20090 BUCCINASCO (MI) ITALY Tel+39-0245712209 Fax+39-0245705836 Internet:www.celmi.com PIN LOAD CELL TYPE PR APPLICATIONS The pin type load cell model PR is mainly foreseen for applications on cranes weighing systems or, in general, where the load applied on a pin have to be measured. Typical applications are: - Crane overload control - Rope load, belt tension measurement, etc. MAIN FEATURES - Immersion proof construction - Stainless steel plasma welded construction - Available with double bridge output (for redundant system) - Available with output (CIA 404) - Available with analog output 4-20mA NOMINAL LOAD : from 500 Kg to 100 Tons SPECIFICATION IN ACCORDING TO VDI/VDE 2637 METROLOGICAL CHARACTERISTICS Nominal load Ln t 0,5÷100 Initial load Lp % Ln 5 Maximum load Ll % Ln 260 Linearity (Best line) Flin ±% Ln 0,5 Hysteresis Fu ±% Ln 0,05 Repeatability Fv ±% Ln 0,04 Creep 30' Fcr ±% Ln 0,03 Nominal temperature range Btn °C -10 +40 Zero temp. coefficient (10°C) TK0 ±% Cn 0,2 Output temp. coefficient (10°C) TKC +% Cn 0,6 Ambient pressare effect Fpr %Ln/KPa 0 ELECTRICAL DATA Output signal at nominal load Cn mV/V 1 Supply voltage nominal range Bsu V 5-12 Maximum supply voltage US max V 15 Input impedante Re Ù 350±1% Output impedante Ra Ù 350±1% Insulation resistance @ 50V Ris M Ù >1000 Zero signal output D0 mV/V ±0,05 MECHANICAL DATA Breaking load Ld % Ln >500 Nominal deflection Hn mm <0,2 Cable lengt m 3 ENVIROMENTAL CONDITIONS Working temperature range Btu °C -10 +40 Storage temperature range Bts °C -40 +85 Housing protection IP-68 All the characteristics depend on the mounting conditions

カタログの1ページ目を開く
PIN LOAD CELL TYPE PR - 2

DESCRIPTION Strain-gage load cells are made by a metallic core over which one or more strain-gages are stick; the strain-gages detect the strain of the metal produced by the load applied on the load cell. The strain-gages are wired in a Wheatstone bridge mode in such a way that the voltage on one diagonal of the bridge (output signal) is proportional to the load and the supply voltage (mV/V). Pin load cells are normally used in single cell weighing systems and, thus, the output signal is not calibrated at zero and full scale as the calibration have to be done, anyhow, at the transmitter....

カタログの2ページ目を開く
PIN LOAD CELL TYPE PR - 3

Type PR SUBJECT TO CHANGE WITHOUT NOTICE Page 3 of 3

カタログの3ページ目を開く

Celmiのすべてのカタログと技術パンフレット

  1. BSW-P

    1 ページ

  2. H9Z2

    2 ページ

  3. Type 387

    2 ページ

  4. BM6G

    2 ページ

  5. General strain gage

    20 ページ

  6. SUS

    2 ページ

  7. SUP14

    2 ページ

  8. L6F

    2 ページ

  9. L6W

    2 ページ

  10. L6T

    2 ページ

  11. SUP13

    2 ページ

  12. SUP12

    2 ページ

  13. SUP11

    2 ページ

  14. SUP7

    2 ページ

  15. SUP6

    2 ページ

  16. SUP2

    2 ページ

  17. SUP1

    2 ページ

  18. L6G

    2 ページ

  19. L6E

    2 ページ

  20. L6N

    2 ページ

  21. L6D

    2 ページ

  22. L6D15

    2 ページ

  23. L6J1

    2 ページ

  24. L6E3

    2 ページ

  25. L6B

    2 ページ

  26. SERIAL BIG DISPLAY

    2 ページ

カタログアーカイブ