DATA SHEET Radar level meter for higher pressure ranges • For level measurement up to 35 m • 4…20 mA/Hart, 2 wires • Adjustable with display/configuration module or PC • ATEX approvals Product variants described in the data sheet may differ from the product presentation and description. Can be combined with Type 2035  Robolux multiway multiport diaphragm valve, pneumatically operated Type 8635  Digital electropneumatic Positioner SideControl Type 8644  Remote Process Actuation Control System AirLINE Type description The Type 8137 is a non-contact radar level measuring device for continuous level measurement. The unit is available in two versions: • with thread and horn antenna (Ø 40 mm) particularly suitable for use in small tanks and process vessels for level measurement of practically any product. • with flange and horn antenna (Ø 40 or 75 mm) particularly suitable for use in storage tanks and process vessels for level measurement of products such as solvent, hydrocarbons and fuels under extremely difficult process conditions. Type 8692  Digital electropneumatic Positioner for the integrated mounting on process control valves 1000105438 | Standard | EU | en | 202011 | 11 © Christian Bürkert GmbH & Co. KG, Subject to alteratio

カタログの1ページ目を開く
Type 8137 - 2

Table of contents 1. General technical data Visit product website 

カタログの2ページ目を開く
Type 8137 - 3

1. General technical data Product properties Material Non wetted parts Housing Cover Seal between housing and cover Cable gland Blind plug Ground terminal Wetted parts Process connection Process seal Antenna Antenna cone Seal Dimensions Weights Measuring variable Measuring range PBT, Stainless steel 316L (1.4404) PC transparent EPDM PA PA Stainless steel 316Ti/316L (1.4571/1.4435) Stainless steel 316L NBR with aramid fibres for device with thread process connection (for others versions not included in the delivery) Stainless steel 316L PTFE (TFM 1600 PTFE) Antenna system: FKM Detailed...

カタログの3ページ目を開く
Type 8137 - 4

Signal resolution Range of the output signal Load resistor Fault signal Max. output current Residual ripple (at DC) 0.3 µA 3.8…20.5 mA/HART (default setting) (Un - Umin.)/0.022 A Current output: mA value unchanged, 20.5 mA, 22 mA or < 3.6 mA (adjustable) 22 mA • For 9.6 V < Un < 18 V: ≤ 0.7 Veff (16…400 Hz) Voltage supply cable • For 18 V < Un < 35 V: ≤ 1.0 Veff (16…400 Hz) • Cable diameter: 5…9 mm • Wire cross-section (spring-loaded terminals): –– massive wire, stranded wire: 0.2…2.5 mm2 (AWG 24…14) –– stranded wire with end sleeve: 0.2…1.5 mm2 (AWG 24…16) Medium data Process temperature...

カタログの4ページ目を開く
Type 8137 - 5

2. Approvals 2.1. ATEX-Certification Note: Devices with Ex certification have different technical data. Certificate Description PTB 08 ATEX 2002X Specifications Ex Ex protection Ex certification Conformity specifications Operating voltage Ui Short circuit rating li Power limitation Pi Ambient temperature Internal capacity Ci Internal inductivity Li Categories 1/2G or 2G EEx ia IIC T6 30 V 131 mA 983 mW - 40 °C…+ 55 °C (- 40 °F…+ 131 °F) (dependent on categories) Negligible Negligible 3. Materials 3.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance...

カタログの5ページ目を開く
Type 8137 - 6

4. Dimensions 4.1. Version with thread horn antenna Note: Dimensions in mm approx. 75.5 Visit product website 

カタログの6ページ目を開く
Type 8137 - 7

4.2. Version with flange horn antenna Note: Dimensions in mm Standard DIN 2501 DIN 2501 ANSI B16.5 ANSI B16.5 Visit product website  

カタログの7ページ目を開く
Type 8137 - 8

5. Performance specifications 5.1. Measurement deviation diagram Measuring deviation [mm] Reference plane Antenna edge Recommended measuring range Measuring range 6. Product operation 6.1. Measuring principle The radar measuring device consists of an electronic housing, a process connection element with antenna and a sensor. The antenna emits short radar pulses with a duration of approximate 1 ns to the medium. These pulses are reflected by the medium surface and received by the antenna as echoes. Radar waves travel at the speed of light. The running time of the radar pulses from emission...

カタログの8ページ目を開く
Type 8137 - 9

6.2. Product operation notes Operating techniques The measuring device provides different operating techniques: • the display/configuration module • the suitable Bürkert DTM in conjunction with adjustment software according to the FDT/DTM standard, e.g. PACTware™ and PC • a HART handheld The entered parameters are generally saved in the measuring device Type 8137. Optionally, parameters may also be uploaded and downloaded with the display/configuration module or saved in a file by using PACTware™/8137‑DTM. Set up with display/configuration module Display/configuration module Description The...

カタログの9ページ目を開く
Type 8137 - 10

7. Ordering information 7.1. Bürkert eShop – Easy ordering and quick delivery Bürkert eShop – Easy ordering and fast delivery d You want to find your desired Bürkert product or spare part quickly and order irectly? Our online shop is available for you 24/7. Sign up and enjoy all the benefits. Order online now 7.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product...

カタログの10ページ目を開く
Type 8137 - 11

Further versions on request Process connection Flange: • DN 80 PN 40 Form C DIN 2501 • DN 150 PN 40 Form C DIN 2501 • DN 200 PN 40 Form C DIN 2501 • 3" 150 lb RF; ANSI B16.5 • 6" 150 lb RF; ANSI B16.5 • 8" 150 lb RF; ANSI B16.5 Temperature Up to + 450 °C 7.4. Ordering chart accessories Description Set with 2 reductions M20 x 1.5/NPT½ + 2 neoprene flat seals for cable gland + 2 screw-plugs M20 x 1.5 Hart-USB Modem Set with a display/configuration module, a transparent cover and a seal ring Set with a transparent cover and a seal ring

カタログの11ページ目を開く

BÜRKERT FLUID CONTROL SYSTEMSのすべてのカタログと技術パンフレット

  1. Type 0121

    16 ページ

  2. Type 6240

    26 ページ

  3. Type 8020

    10 ページ

  4. Type 8026

    12 ページ

  5. Type 8605

    13 ページ

  6. Type 8692

    18 ページ

  7. Type 5470

    15 ページ

  8. 8041

    10 ページ

  9. Type 0498

    6 ページ

  10. Type 8081

    9 ページ

  11. Type 2300

    32 ページ

  12. Type 8012

    21 ページ

  13. Type 8110

    11 ページ

  14. Type 8010

    14 ページ

  15. 8222

    8 ページ

  16. Typ 8804

    12 ページ

  17. Proportional Valves

    17 ページ

  18. Measurement devices

    68 ページ

  19. Solenoid Valves

    31 ページ

  20. 6240

    11 ページ

  21. Type 0301

    4 ページ

  22. Type 0201

    4 ページ

  23. Type 0300

    6 ページ

  24. Type 0200

    6 ページ

  25. Type 0131

    4 ページ

  26. Type 0142

    4 ページ

  27. Type 0117

    3 ページ

  28. Type 0293

    3 ページ

  29. Diaphragm Competence

    14 ページ

  30. AirLINE SP

    2 ページ

  31. eControl Type 8611

    2 ページ

  32. Dosing Systems

    4 ページ

  33. CUT Product Line

    9 ページ

  34. Cooling Towers

    2 ページ

  35. MicroFluidics

    2 ページ

  36. Fuel Cell Tech

    2 ページ

  37. Robot Welding

    2 ページ

  38. Plastic Extruding

    2 ページ

  39. Flyer Cooking

    2 ページ

  40. Injection Molding

    2 ページ

  41. Heat Exchanger

    2 ページ

  42. Clean Steam

    2 ページ

  43. Food and Beverage

    32 ページ

  44. Company profile

    15 ページ

  45. steam products

    16 ページ

カタログアーカイブ

  1. Type 6281

    21 ページ

  2. 6281

    13 ページ