カタログの抜粋

Conductivity meter • Analog 4…20 mA output • Universal process connection • Three cell constants for covering a wide measuring range • Temperature compensated measurement Type 8222 neutrino can be combined with… Type 8611 eCONTROL Universal controller Type 8619 multiCELL Transmitter/Controller The Bürkert neutrino meter Type 8222 is a compact device designed for measuring the conductivity of fluids. The conductivity meter consists of a sensor plugged-in and pined to an enclosure with cover, containing the electronic module. The sensor holder comprises a cell with two electrodes and a Pt1000 temperature sensor. The sensor itself is available with three different cell constants C, these with C = 0.01 or 0.1 are fitted with stainless steel electrodes and this with C = 1.0 is fitted with graphite electrodes. The neutrino conductivity meter Type 8222 is available with one 2-wire 4…20 mA current output and with two different connections: either a G 1½ union nut for adaptor with G 1½ external threaded sensor connection or a G ¾ threaded holder for screwing into an adaptor with G ¾ internal thread sensor connection. Type 8693 Process controller Type 8802 ELEMENT Control valve system Type S022 Insertion Adapter/ Fitting for ELEMENT analytical devices Technical data (Pipe + conductivity meter) Pipe diameter DN25…DN110 (DN < 25 with reduction) Conductivity measurement Measuring range 0.05 µS/cm…10 mS/cm Measurement deviation ±3 % of measured value Temperature measurement Measuring range -20…+100 °C (-4…+212 °F) Measurement deviation ±1 °C (1.8 °F) Temperature compensation according to a predefined graph (none, NaCl, ultra pure water), selectable via a switch Fluid temperature 0…+50 °C (+32…+122 °F) with G 1½ PVC connection nut with G 1½ PVDF connection nut -20…+100 °C (-4…+212 °F) restricted by the used adap(on request) tor; restriction with adaptor S022 in: - PVC: 0…+50 °C (+32…+122 °F) - PP: 0…+80 °C (+32…+176 °F) - Metal: -20…+100 °C (-4…+212 °F) with G ¾ external threaded connection Fluid pressure max Environment Ambient temperature Relative humidity -20…+100 °C (-4…+212 °F) restricted by the used adaptor; restriction with adaptor S022 in: - PVC: 0…+50 °C (+32…+122 °F) - PVDF: 0…+100 °C (+32…+212 °F) - Metal: -20…+100 °C (-4…+212 °F) PN16 (232 PSI) (see pressure / temperature chart) -10…+60 °C (+14…+140 °F) (operating and storage) ≤ 85 %, without condensation The electronics of Type 8222 conver
カタログの1ページ目を開く
8222 ELEMENT neutrino Materials view General data Compatibility Materials Housing Cover Seals Fixed connector Nut Wetted part materials Temperature sensor Conductivity electrodes Temperature sensor Electrical connections Recommended connection cable for terminal strip Solid H05(07) V-U Flexible H05(07) V-K With wire end ferrule With plastic collar ferrule Diameter Electrical data Power supply Characteristics of the power source (not provided) of UL recognized devices Any pipe which are fitted out with Bürkert adaptor S022 (see separate data sheet) See exploded view, opposite Stainless...
カタログの2ページ目を開く
8222 ELEMENT neutrino Pressure/temperature chart Application range of a 8222 ELEMENT neutrino conductivity meter: A: with PVDF nut (on request) or G ¾ external threaded connection B: with PVC nut The measures have been made at an ambient temperature of 60 °C. Application range of a 8222 ELEMENT neutrino conductivity meter • with PVDF nut (on request) with S022 adaptor Pressure (bar) • with PVC nut with S022 adaptor PVC • with G ¾ threaded connection with S022 adaptor 16
カタログの3ページ目を開く
8222 ELEMENT neutrino Principle of operation Conductivity is defined as the ability of a solution to conduct electrical current. The load carriers are ions (E.G. dissolved salt or acids). In order to measure conductivity 2 electrodes are used which are set at a fixed distance apart and with a known specified surface. An AC voltage source is connected to the electrodes. The measured current is a direct function of the conductivity of the solution. The conductivity meter is a two-wire device, which requires a power supply of 12…36 V DC. The conductivity meter can be fitted with 3 different...
カタログの4ページ目を開く
8222 ELEMENT neutrino Dimensions [mm] of conductivity meter Type 8222 with a G 1½ union connection nut 87 86.5 with a G ¾ external threaded connection 86.5 C=1 Threading dimensions plan (for installation of the conductivity meter with a G¾" external threaded connection) Ø28H8 G3/4"
カタログの5ページ目を開く
8222 ELEMENT neutrino Ordering information for compact conductivity meter, Type 8222 A complete compact ELEMENT neutrino conductivity meter, Type 8222, consists of: - compact ELEMENT neutrino conductivity meter, Type 8222, with a G 1½ union connection nut and a Bürkert S022 Insertion adaptor with a a G 1½ external threaded sensor connection. The following information is necessary for the selection of a complete device: •Article no. of the desired 8222 ELEMENT neutrino conductivity meter with a G 1½ union connection nut (see ordering chart on p. 7) •Article no. of the selected S022...
カタログの6ページ目を開く
8222 ELEMENT neutrino Ordering chart for compact conductivity meter Type 8222 Specifications Compact conductivity meter with a G 1½ union connection nut Electrical connection 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland Compact conductivity meter with a G ¾ external threaded connection 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland 5 pin M12 male fixed connector Cable gland
カタログの7ページ目を開くBÜRKERT FLUID CONTROL SYSTEMSのすべてのカタログと技術パンフレット
-
Type 0121
16 ページ
-
Type 6240
26 ページ
-
Type 8020
10 ページ
-
Type 8026
12 ページ
-
Type 8605
13 ページ
-
Type 8692
18 ページ
-
Type 5470
15 ページ
-
8041
10 ページ
-
Type 0498
6 ページ
-
Type 8081
9 ページ
-
Type 2300
32 ページ
-
Type 8012
21 ページ
-
Type 8110
11 ページ
-
Type 8010
14 ページ
-
Type 8137
12 ページ
-
Typ 8804
12 ページ
-
Proportional Valves
17 ページ
-
Measurement devices
68 ページ
-
Solenoid valves 6240
9 ページ
-
Solenoid Valves
31 ページ
-
6240
11 ページ
-
Type 0301
4 ページ
-
Type 0201
4 ページ
-
Type 0300
6 ページ
-
Type 0200
6 ページ
-
Type 0131
4 ページ
-
Type 0142
4 ページ
-
Type 0117
3 ページ
-
Type 0293
3 ページ
-
Process & Control Valves
33 ページ
-
Diaphragm Competence
14 ページ
-
Standard Product Program
13 ページ
-
AirLINE SP
2 ページ
-
multiCELL Type 8619
5 ページ
-
Flowmeter Type 8045
4 ページ
-
eControl Type 8611
2 ページ
-
Dosing Systems
4 ページ
-
CUT Product Line
9 ページ
-
CATALOGUE BURKERT SELECT
88 ページ
-
Cooling Towers
2 ページ
-
MicroFluidics
2 ページ
-
Fuel Cell Tech
2 ページ
-
Robot Welding
2 ページ
-
Plastic Extruding
2 ページ
-
Flyer Cooking
2 ページ
-
Injection Molding
2 ページ
-
Heat Exchanger
2 ページ
-
Clean Steam
2 ページ
-
Food and Beverage
32 ページ
-
Systemhaus Brochure
8 ページ
-
Company profile
15 ページ
-
Cooling Systems Brochure
16 ページ
-
Water Treatment Brochure
16 ページ
-
MicroFluidics Brochure
16 ページ
-
steam products
16 ページ
-
Product overview Sensors
52 ページ