HT COMBI419 Innovative meter designed to perform all safety test

カタログの1ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 2

Description COMBI419 and COMBI420 is an innovative meter designed to perform all safety test verifies on electrical installations in compliance to recently standards (VDE0100, BS7671 and so on, measure and save results of [environmental parameters (illuminanance, temperature, sound level) 420], leakage currents and [active power, harmonics, power factor measurements on single phase systems 420]. The meter it's very easy to use and have a wide number of internal features which are selectable by using the multilanguage menu. The instrument permits, moreover, to start principal measures by...

カタログの2ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 3

quickly selection of available test AUTOMATIC function to perform all safety tests through loop impedance measurements High resolution (0.1 mQ) loop impedance

カタログの3ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 4

MODELS AND FEATURES Measurements Continuity test on protective conductor with 200mA Insulation resistance 50-100-250-500-1000VDC RCDs tripping time and current (general and selective, AC and A types) 10-30-100-300-500mA Contact voltage Ut Loop impedance P-N, P-P, P-PE Loop impedance P-N, P-P, P-PE with high resolution (0.1m ) with IMP57 optional accessory Prospective short circuit current Global earth resistance Ra without RCDs tripping Phase sequence Leakage current (with HT96U optional accessory) AUTOMATIC test (Ra, RCD time, Insulation) directly on outlet Using optional remote probe...

カタログの4ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 6

ELECTRICAL SPECIFICATIONS Accuracy is indicated as ± (% rdgs + no. of dgt) at 23°C ± 5° con relative humidity <60%RH C, (*) Technical specification can be modified without notice Continuity test on protective conductors (*) after cable calibration which eliminates the cable resistance >200mA DC per R Test current CAT III 240V to Ground CAT III 415V between inputs (calibration included) current measurement resolution: 1mA Open leads voltage RCDs tripping time Resolution ms CAT III 240V to Ground CAT III 415V between inputs Nominal tripping current Phase-ground voltage Voltage contact limits...

カタログの6ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 7

Insulation resistance (DC voltage) V 1000 ~ 1999 Open leads voltage Test voltage 1.1 x nominal test voltage voltage measurement resolution:1V Short circuit current Nominal current the instrument returns an error message while detecting an input voltage >30V CAT III 240V to Ground, CAT III 415V between inputs CAT III 240V to Ground, CAT III 415V between inputs Loop impedance P-P, P-N, P-PE Range ( ) 0.01 ~ 9.99 Maximum peak current Test voltage Category of measure range (with option accessory IMP57) 3.65A @ 127V; 6.64A @ 230V; 11.5A @ 400V 100÷265V (phase-neutral) / 100÷460V (phase-phase);...

カタログの7ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 8

Global Earth Resistance RA without tripping the RCD Range ( ) Test voltage CAT III 240V to Ground, CAT III 415V between inputs Phase sequence with 1 or 2 wires Range (V) correct phase sequence wrong phase sequence phase coincidence Category of measure CAT III 240V to Ground CAT III 415V between inputs The instrument detects the phase sequence by touching the hot wire. The detection is not performed on insulated cables Frequency Leakage current AC TRMS (amperometric input) mV Frequency range CAT I 30V to Ground and between inputs GENERAL SPECIFICATIONS MECHANICAL FEATURES Dimensions Weight...

カタログの8ページ目を開く
Multifunction Tester for Safety Tests and Power Analysis COMBI419 - 9

GE0416-Low batteries indications 'L^JJT Symbol at display POWER SUPPLY Battery life > 600 measurements (without using the timer) ENVIRONMENTAL CONDITIONS Reference temperature of calibration (23 °C ± 5°C) Storage temperature (batteries not included) -10°C ~ 60 °C GENERAL REFERENCE STANDARDS EMC 89/336/EEC guideline amended with 93/68/EEC (IEC61326) Insulation class 2 (double insulation) Overvoltage category of the voltage inputs (installation/measurement) CAT III 240V to ground, 415V between inputs Overvoltage category of the AUX input Safety of measuring instruments IEC / EN61010-1 Product...

カタログの9ページ目を開く

BST Caltek Industrial Ltdのすべてのカタログと技術パンフレット

  1. BC-30 DR

    4 ページ

  2. PSM3-30/3

    3 ページ

  3. ER-81

    3 ページ

  4. BC-20 DR

    5 ページ

  5. BS33

    3 ページ

カタログアーカイブ

  1. PSD-A/B/C Series

    4 ページ

  2. PSM2/2A

    4 ページ

  3. BT514

    5 ページ

  4. BT513

    5 ページ

  5. BT512

    5 ページ

  6. BT511

    5 ページ

  7. BT502

    2 ページ

  8. BT501

    2 ページ

  9. BT521

    2 ページ

  10. BT701

    3 ページ

  11. M73

    9 ページ

  12. GSC53N

    10 ページ

  13. COMBI420

    11 ページ

  14. COMBI419

    9 ページ

  15. Clamp Meter BS92

    6 ページ

  16. Scope Meter

    4 ページ