Improved Detection Capabilities by Fast Data Acquisition in ICP-MS René Chemnitzer, Meike Hamester Bruker Daltonik GmbH, Bremen Germany
カタログの1ページ目を開く
Why do we need improvements in sensitivity and scan speed Scan Speed Sensitivity Laser ablation • Small samples – inclusions Isotope ratio / isotopic abundance Fast scan speed, signal is limited in time High sensitivity - isotopic Elemental mapping - resolution abundance varies Better detection limits Better peak characterization Multi-element acquisition Lower injection volumes Single particles • Smaller particles
カタログの2ページ目を開く
Let‘s talk about spot diameter Laser ablation on crystalline samples • Limited sample size means – interest in smallest possible spot sizes If the diameter is in-/decreased by a factor of two the amount of sample changes by a factor of 4 To change from ~50µm to 20µm means more than 4 times less material
カタログの3ページ目を開く
Laser ablation on zircon crystals Photon-Machines Inc. 193nm excimer laser 4ns pulse duration, spot size down to 2µm Bruker aurora Elite ICP-MS
カタログの4ページ目を開く
position in the ablation chamber zoomed CCD camera view of the ablation site Laser settings Screen image of photon-machines Chromium software showing zircon crystals prior to ablation.
カタログの5ページ目を開く
Isotope ratio results for Zircon GJ1 Bruker Corporation
カタログの6ページ目を開く
Samples: R10b and R13, Age: 1090Ma and 505±6Ma A.K. Schmitt, Th. Zack, Chemical Geology 332-333, 2012, 65-73
カタログの7ページ目を開く
Samples: R10b and R13 Age: 1090Ma and 505±6Ma A.K. Schmitt, Th. Zack, Chemical geology 332-333, 2012, 65-73 Improve signal stability Better precision
カタログの8ページ目を開く
It‘s all about timing… analysis of nanoparticles • The peak width of the ion plume entering the MS is about 300 μs.
カタログの9ページ目を開く
Acquisition of single particles Bruker Corporation
カタログの10ページ目を開く
Detection limit for Nanoparticles • 60nm Gold nanoparticle • Dwell time: 100µs • Sensitivity – 300 counts
カタログの11ページ目を開く
Enhanced performance through membrane desolvation Have you ever seen >10Mio cps/ppb…at 0.2% oxides
カタログの12ページ目を開く
Cetac AridusII + Bruker aurora Elite lime Scan Setup... Bruker Corporation
カタログの13ページ目を開く
Summary All-digital Detection System Unmatched Sensitivity • High efficiency plasma and ion optic • Excellent detection limits • Attractive to laser ablation and other application markets • Only detector to offer 109 working range in pulsecounting (digital) mode. • No cross-calibration of digital-analog modes required Simplified Interference Management • Innovative Collision-Reaction Interface (CRI) • Hollow ion mirror design requires no cleaning • Removes interferences at plasma interface, not the ion beam • No need for additional cleaning / replace of interference management technology •...
カタログの14ページ目を開く
Thank you for your attention !
カタログの15ページ目を開くBruker Daltonicsのすべてのカタログと技術パンフレット
-
SVGps
4 ページ
-
RAPIDplus
7 ページ
-
TIMON
13 ページ
-
RoadRunner
5 ページ
-
MATRIX-MG Series
7 ページ
-
RAID-XP
5 ページ
-
RAID-M Series
7 ページ
-
HDX Solution
2 ページ
-
EVOQ GC-TQ
8 ページ
-
timsTOF PRO
8 ページ
-
PesticideScreener
8 ページ
-
Elute LC series
8 ページ
-
nanoElute®
6 ページ
-
timsTOF™
8 ページ
-
rapifleX™
8 ページ
-
amaZon SL
6 ページ
-
compact
8 ページ
-
MALDI Biotyper
56 ページ
-
MALDI PharmaPulse™
4 ページ
-
Toxtyper
6 ページ
-
impact II
12 ページ
-
maxis II
12 ページ
-
amaZon speed
10 ページ
-
Albira Brochure
12 ページ
-
prime
12 ページ
-
solarix
10 ページ
-
Metabolomics
12 ページ
-
aurora M90
10 ページ
-
Clean Room Pack
4 ページ
-
TANGO
12 ページ
-
The new autoflex? series
10 ページ
-
MM 2
6 ページ
-
µRAID
4 ページ
-
solariX XR
12 ページ
-
aurora Elite
6 ページ
-
nano-Advance UHPLC
8 ページ
-
EVOQ
12 ページ
-
CaptiveSpray
4 ページ
-
ImagePrep
4 ページ
-
micrOTOF-Q II
12 ページ
-
PROTEINEER fc II
4 ページ
-
Ultraflextreme
16 ページ
-
Autoflix speed
10 ページ
-
microflex
6 ページ
-
SCION 436-GC
4 ページ
-
SCION 456-GC
4 ページ
-
GC CARE
8 ページ
-
Brochure BioTools 2.2
10 ページ
-
Brochure micrOTOF II
8 ページ
-
Brochure EASY-nLC
6 ページ
カタログアーカイブ
-
impact HD
12 ページ
-
RAID-M 100
6 ページ
-
compact?
6 ページ
-
micrOTOF-Q III
6 ページ
-
Toxtyper
8 ページ
-
MALDI Biotyper
12 ページ