BS Single-phase asynchronous motors
1 / 20ページ

{{requestButtons}}

カタログの抜粋

BS Single-phase asynchronous motors - 1

BS series Single-phase asynchronous motors Bonfiglioli has been designing and developing innovative and reliable power transmission and control solutions for industry, mobile machinery and renewable energy applications since 1956. HeadquarterS Bonfiglioli Riduttori S.p.A. Via Giovanni XXIII, 7/A 40012 Lippo di Calderara di Reno Bologna (Italy)

カタログの1ページ目を開く
BS Single-phase asynchronous motors - 3

1.1 - PRODUCT DESIGNATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.2 - STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.2.1 - Technical norms . . . . . . . . . . . . . . . . . . . . . ....

カタログの3ページ目を開く
BS Single-phase asynchronous motors - 4

D1 - thermal protection PS - extended shaft at NDE RC - rain canopy AE - balanced winding DEGREE OF PROTECTION IP55, IP56 CAPACITOR SC - run capacitor DC - starting + run capacitor REMARK: Values marked in bold represent the factory standard setting. If not otherwise specified at the time of order, for each variant the configuration marked in bold will be assumed. jfi\BONFIGLIOLI RIDUTTORI

カタログの4ページ目を開く
BS Single-phase asynchronous motors - 5

1.2 - STANDARDS 1.2.1 - Technical norms Single-phase motors described in this catalog are of the enclosed type, fan ventilated and with run capacitor permanently connected. Motors are designed for use in industrial environments and are manufactured in accordance with applicable CEI /EN and IEC standards as listed in the following table: 1.2.2 - European directives CEE 73/23 (LVD) and CEE 89/336 (EMC) Bonfiglioli single-phase motors meet the requirements of Directives 73/23/EEC (Low Voltage Directive) and 89/336/EEC (Electromagnetic Compatibility Directive) and their nameplates bear the CE...

カタログの5ページ目を開く
BS Single-phase asynchronous motors - 6

1.3.1 - Electrical tolerances The following tolerances are permitted according to CEI EN 60034-1: jfi\BONFIGLIOLI RIDUTTORI

カタログの6ページ目を開く
BS Single-phase asynchronous motors - 7

2.0 - ELECTRICAL FEATURES 2.1 - OPERATING CONDITIONS 2.1.1 - Voltage In their standard configuration motors are designed for 230V-50Hz supply. Upon request, motors can also be specified for 115V-60Hz or 230V-60Hz supply. 2.1.2 - Type of duty Motor outputs listed in this catalogue refer to S1 continuous duty. For motors operated at duties other than S1, as per Norms CEI EN 60034-1, please refer to Bonfiglioli’s Technical Service for advise. Single-phase motors have greater losses when they run idle than in full load operation. Running idle for a long period is therefore NOT recommended....

カタログの7ページ目を開く
BS Single-phase asynchronous motors - 8

2.3 - INSULATION CLASS Bonfiglioli motors use, as standard, class F insulating materials (enamelled wire, insulators, impregnation resins). For applications in the presence of aggressive chemicals or high humidity, contact Bonfiglioli Technical Service for assistance with product selection. On request, motors to insulation class H can be specified. Temperature rise allowed 2.4 - THERMAL PROTECTION Motors may be supplied with a built-in thermal protector preventing the stator windings from overheating due to poor ventilation or highly intermittent duty. Thermal protectors consist of a...

カタログの8ページ目を開く
BS Single-phase asynchronous motors - 9

2.5 - REVERSING Motors are supplied with run capacitor permanently connected and can be operated in both directions of rotation. Motors can be reversed by switching the wiring, as shown in the diagram below, through a remote control switch. In the diagram below shaft are viewed from the drive end. Prior to reversing, make sure the motor is at standstill. AE For a facilitated reversing through a simple switch, single-phase motors can be designed with symmetrical windings and run capacitor permanently connected. For this arrangement specify option AE in the ordering code. This particular...

カタログの9ページ目を開く
BS Single-phase asynchronous motors - 10

3.1 - BEARINGS Grease-packed, axially locked ball bearings ensure maintenance free operation. Nominal endurance lifetime L10h exceeds 40,000 hours assuming no overhung load on the shaft, and mounting position horizontal. The types of bearings in use are listed in the table below. jfi\BONFIGLIOLI RIDUTTORI

カタログの10ページ目を開く
BS Single-phase asynchronous motors - 11

3.4 - MOTOR MOUNTING Motors are available in the type of construction IM B5, IM B14 and derived versions in accordance with standard CEI EN 60034-7, as shown in the table below. Motors may also be specified for vertical mounting, however the name plate will only show the corresponding basic design version: If motor is to be installed with the shaft end pointing down, the rain canopy is recommended and should be specified through the option RC. Flanged motors can also be requested with reduced shaft and flange dimensions, specifying the design versions B5R or B14R. Relevant dimensions are...

カタログの11ページ目を開く
BS Single-phase asynchronous motors - 12

3.6 - SECOND SHAFT EXTENSION AT NON-DRIVE END Specify option PS in the ordering code The option PS is not compatible with the rain canopy RC preventing the ingress of water and solid bodies. Refer to dimensional drawing for relevant shaft dimensions 3.7 - RAIN CANOPY Option The rain canopy is an optional device that protects the motor from the ingress of solid bodies and dripping water. It is highly recommended when motor is to be installed with the shaft end pointing down. Relevant dimensions are listed in the following table. The canopy is not compatible with the second shaft extension,...

カタログの12ページ目を開く
BS Single-phase asynchronous motors - 14

SHAFT FLANGE MOTOR (#) Starting capacitor - option DC. |Sgi\ BONFIGLIOLI RIDUTTORI

カタログの14ページ目を開く
BS Single-phase asynchronous motors - 15

SHAFT FLANGE MOTOR (#) Starting capacitor - option DC.

カタログの15ページ目を開く
BS Single-phase asynchronous motors - 16

INDEX OF REVISIONS (R) We reserve the right to implement modifications without notice. This catalogue cannot be reproduced, even partially, without prior consent. jfi\BONFIGLIOLI RIDUTTORI

カタログの16ページ目を開く
BS Single-phase asynchronous motors - 18

Industry Process and Automation Solutions headquarters BONFIGLIOLI RIDUTTORI S.p.A. Via Giovanni XXIII, 7/A 40012 Lippo di Calderara di Reno Bologna (ITALY) Tel. (+39) 051 6473111 Fax (+39) 051 6473126 www.bonfiglioli.com bonfiglioli@bonfiglioli.com spare parts bonfiglioli B.R.T. Via Castagnini, 2-4 Z.I. Bargellino - 40012 Calderara di Reno - Bologna (ITALY) Tel. (+39) 051 727844 Fax (+39) 051 727066 www.brtbonfiglioliricambi.it brt@bonfiglioli.com Australia BONFIGLIOLI TRANSMISSION (Aust) Pty Ltd. 48-50 Adderley St. (East) Auburn (Sydney) N.S.W. 2144 Tel. (+61) 2 8748 4400 - Fax (+61) 2...

カタログの18ページ目を開く

Bonfiglioliのすべてのカタログと技術パンフレット

  1. Marine and Offshore

    20 ページ

  2. HDP

    88 ページ

  3. Worm Gear Series

    86 ページ

  4. V series Motovariator

    362 ページ

  5. Wind Solutions

    24 ページ

  6. Solutions for Mining

    20 ページ

  7. 600W2/3 Series

    2 ページ

  8. 610X Series

    2 ページ

  9. 600Y3 Series

    2 ページ

  10. 600W series

    2 ページ

  11. Active Cube 7

    2 ページ

  12. Power Drive VCB400

    16 ページ