Onduleurs • Redresseurs • Batteries Applications | Industry | Healthcare | Datacenter Active Power Filter Power Factor Correction The Aunilec APF not only compensate harmonic current but also the reactive power. It is able to correct for either a leading or lagging power factor. Modular design, easy to extend Up to 12 harmonic orders selective individually Close/open Loop control Improves lagging and leading power factor at input loads Unbalanced loads compensation Reduces apparent power consumption at the supply and saves costs Resolves nuisance tripping of MCCBs Programmable power factor correction Full-time DSP control system Easy selection and maintenance Shunt connection Flexible upgrading and redundancy Parallel operation with different capacity User friendly LCD control panel Rack/wall installation THD= 0.1% THD= 0.1% THD= 0.1% THD= 2.4% THD= 2.4% THD= 2-4% The user friendly LCD display offers access to all parameters, waveforms, harmonic spectrum system power quality, settings, status and alarms, Close/Open Loop Control The CT is allowed to install at source or load side for measure the harmonic current from the load. When CT is installed at source side, the close loop control method is used for best accuracy of harmonic current compensation. (When CT is installed at the load side, the open loop control will be used). Harmonic Current Generator The Aunilec APF behaves like a harmonics current generator. It will measure the harmonic generated from the non-linear loads and cancel these harmonics with a newly generated, opposite phase shifted harmonics current of the same amplitude.
カタログの1ページ目を開く
Applications | Industry | Healthcare | Datacenter Onduleurs • Redresseurs • Batteries Input voltage Compensated harmonic orders Power Factor correction Response time Controllable power module Number of power module Dimensions (WxDxH) Input voltage De-rating compensation current/phase Max. compensation current for neutral Inrush current Current limitation Dimensions (WxDxH) Storage temperature Operating temperature Relative humidity Harmonic and design standards Software (optional) Control panel Compensate both lagging and leading reactive power (programmable) Can be set, primary current:...
カタログの2ページ目を開くAUNILECのすべてのカタログと技術パンフレット
-
Datasheet MULTI PLUS
5 ページ
-
Datasheet IRIS+
2 ページ
-
Datasheet IRIS+L
2 ページ
-
Datasheet HELIOS TH
4 ページ
-
Datasheet AUPUS WRS
4 ページ
-
Datasheet VEGA HE
4 ページ
-
Datasheet HELIOS MPW
8 ページ
-
Datasheet AESB-R
2 ページ
-
ARES RT 1000-3000VA
2 ページ
-
ARES 1000-3000VA
2 ページ
-
EPC D 600/800VA
2 ページ
-
Aunilec ARES
2 ページ
-
after-sales service
6 ページ
-
Inverters AUPUS EIM
3 ページ
-
AESATM/TT 10-80kVA
3 ページ
-
INV 48V/300VA
1 ページ
-
Aunilec Batteries
1 ページ
-
Aunilec VEGA
6 ページ
-
Aunilec ARFDin
2 ページ
-
Série EOS 650-2200VA
2 ページ
-
NET600 600VA
2 ページ
-
Datasheet INV
3 ページ
-
Datasheet DSP
4 ページ
-
Datasheet MultiPlus
4 ページ
-
Datasheet OP 5_10kVA
2 ページ
-
Datasheet OP 1_3kVA
2 ページ
-
Datasheet CRFw
2 ページ
-
Datasheet ARFDin
2 ページ
-
Datasheet Helios 20S
2 ページ
-
Datasheet Helios STR
2 ページ
-
Datasheet MPTR
2 ページ
-
Datasheet RDC
4 ページ
カタログアーカイブ
-
Datasheet AESA
2 ページ
-
HELIOS MPW
7 ページ
-
AUPUS HE Cabinet
6 ページ
-
Power solutions
48 ページ
-
UPS catalogue 2019-2020
60 ページ
-
Gel batteries
2 ページ
-
Carbon battery
3 ページ
-
Charger CRFD
2 ページ
-
Datasheet ARES Rack
2 ページ
-
Live&smart MLTDSP EN
2 ページ
-
Lead Carbon battery
2 ページ
-
Datasheet RCRFn
2 ページ