カタログの抜粋

posichron® Magnetostrictive Position Sensors PCFP25 Displacement sensor in ultra flat profile for tight mounting spaces Ultra flat profile housing: only 8 mm high Wear and maintenance free High level of shock resistance up to 50 g (100 shocks) Guiding distance of up to 19 mm (depending on magnet/profile) Product versions Analog output, 1 channel Analog output, 2 channels Digital output
カタログの1ページ目を開く
PCFP25 - Magnetostricitve Position Sensor in ultra flat profile Version with analog output, 1 channel Specifications Order options, 1 channel Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request 0 ... 10 V signal conditioner U1 with alarm_HOLD 0.5 ... 10 V signal conditioner U2 with alarm_LOW; U2 with alarm_HOLD 0.5 ... 4.5 V signal conditioner U8 with alarm_LOW; U8 with alarm_HOLD 4 ... 20 mA signal conditioner (3 wire) I1 with alarm_LOW; I1with alarm_HOLD Function and characteristics output Position magnet 1, increasing Position magnet 1, decreasing Start value,...
カタログの2ページ目を開く
PCFP25 - Magnetostricitve Position Sensor in ultra flat profile Version with analog output, 2 channels Specifications Order options, 2 channels Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request 0 ... 10 V signal conditioner U1 with alarm_HOLD 0.5 ... 10 V signal conditioner U2 with alarm_LOW; U2 with alarm_HOLD 0.5 ... 4.5 V signal conditioner U8 with alarm_LOW; U8 with alarm_HOLD 4 ... 20 mA signal conditioner (3 wire) I1 with alarm_LOW; I1with alarm_HOLD Function and characteristics, output 1 Position magnet 1, increasing Position Magnet 1, decreasing...
カタログの3ページ目を開く
1) VZx.x = velocity with direction detection (with 1 magnet only), in steps of 0.1 m/s Example: VZ1.5 towards start position 2) VAx.x = velocity without direction detection (with 1 magnet only), in steps of 0.1 m/s Example: VA1.5 towards start position Accessories: Position magnets (see page 12) Mounting sets (see page 9)
カタログの4ページ目を開く
PCFP25 - Magnetostricitve Position Sensor in ultra flat profile Version with digital output SSI Specifications Order options Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request Synchronous serial interface (SSI) Output code Gray Dual Number of data bits Sampling rate Up to 1 kHz, depending on the measurement range Housing material Protection class Cable, standard length 2 m Temperature range Order example: PCFP25 – 1000 – 5 – SSI / G / 24 ‒ L10 – KAB2M Accessories: Position magnets (see page 12) Mounting sets (see page 9)
カタログの5ページ目を開く
PCFP25 - Magnetostricitve Position Sensor in ultra flat profile Version with digital output CANopen Specifications Order options Measurement range 100 ... 5750 (in 10 mm increments) other lengths upon request CANopen-Bus CANopen-Bus with integrated terminating resistance CAN SAE J1939 CAN SAE J1939-Bus with integrated terminating resistance Sampling rate Up to 1 kHz, depending on the measurement range Housing material Protection class Cable (length 0.3 m) with connector M12, 5 pin Temperature range Order example: PCFP25 – 1000 – CANOP – L10 – KAB0,3M-M12/CAN Accessories: Connector cable...
カタログの6ページ目を開く
Dimensions Cable output A – Start position B – End position C – Total length = Measurement length + 162 [6.378] (e.g. 262 [10.315]) D – Measurement length (e.g. 100 [3.937]) Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
カタログの7ページ目を開く
Magnet positions Alternative magnet positions
カタログの8ページ目を開く
Mounting sets Mounting set PCFP25-BFS1 D – Alternative magnet position A – Mounting clamp B – Isolation sleeve C – Isolation strip E - Marking Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
カタログの9ページ目を開く
Mounting set PCFP25-RF-BFS1 Redundant version Horizontal arrangement A – Mounting clamp B – Isolation sleeve C – Isolation strip E – Marking Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
カタログの10ページ目を開く
Mounting set PCFP25-RH-BFS1 Redundant version Vertical arrangement A – Mounting clamp B – Isolation sleeve C – Isolation strip E – Marking Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
カタログの11ページ目を開く
Magnets PCMAG5 Standard magnet Dimensions in mm [inch] Dimensions informative only. For guaranteed dimensions consult factory.
カタログの12ページ目を開く
Output specification Analog output U1 Voltage output 0 ... 10 V Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature Excitation voltage Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature Excitation voltage
カタログの13ページ目を開く
Excitation current Output voltage Output current Output load Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature I1 Current output 4 … 20 mA, 3 wire Excitation voltage Excitation voltage Excitation current Output current Stability (temperature) Reverse polarity, short circuit Output noise Operating temperature
カタログの14ページ目を開く
Diagnostic on analog outputs Behaviour of the analog signal output in case of error In case of error (magnet missing or outside the measuring range) the analog output signal will assume a state according to the following options: Alarm_HIGH The output voltage resp. the output current is at HIGH level (overrange). Alarm_LOW The output voltage resp. the output current is at LOW level (underrange). Alarm_HOLD The output voltage resp. the output current will keep the last valid state. keeps last valid state (Order code U1/H) Uout < 0.25 V (Order code U2/U) keeps last valid state (Order code...
カタログの15ページ目を開く
Synchronous serial interface SSI Excitation voltage 10 … 36 V DC, residual ripple 10 mVss Excitation current Clock frequency Gray-Code, Dual-Code Delay between pulse trains (tp) Stability (temperature) Operating temperature The data transmission takes place by means of the two signals CLOCK and DATA. The processing unit (PLC, microcomputer) sends pulse sequences which clock the data transmission at the required transfer rate. With the first falling edge of the pulse sequence the position of the sensor is recorded and stored. The following rising edges control the bit-by-bit transfer of the...
カタログの16ページ目を開くASM Automation Sensorik Messtechnik GmbHのすべてのカタログと技術パンフレット
-
System NMG2
4 ページ
-
PTK7
9 ページ
-
PTK6
9 ページ
-
PTK29
7 ページ
-
PTDM7
8 ページ
-
PTAM7
12 ページ
-
PTDM6
8 ページ
-
PTAM6
13 ページ
-
PTDM5
10 ページ
-
PTAM5
13 ページ
-
PTAM4
9 ページ
-
PTAM2
16 ページ
-
PTAM27
9 ページ
-
PTM29
10 ページ
-
AWS
5 ページ
-
PH68
19 ページ
-
PH58
21 ページ
-
PH36
21 ページ
-
PRAS7
18 ページ
-
PRAS6
19 ページ
-
PRAS5
25 ページ
-
PRAS4
8 ページ
-
PRAS3
19 ページ
-
PRAS1
12 ページ
-
PRAS29
15 ページ
-
PRAS27
16 ページ
-
PRAS26
13 ページ
-
PRAS20
12 ページ
-
PMIB3
7 ページ
-
PMIS3
8 ページ
-
posichron® EasyMount
6 ページ
-
PCRP32
18 ページ
-
PCST27
26 ページ
-
PCST25
27 ページ
-
PCST24
29 ページ
-
PCRP21
23 ページ
-
PCQA24
24 ページ
-
PCQA22
24 ページ
-
PCFP24
22 ページ
-
PCFP23
24 ページ
-
WB100M
21 ページ
-
WST 21
9 ページ
-
WB21
26 ページ
-
WST85
6 ページ
-
WB85
22 ページ
-
WST61
6 ページ
-
WB61
22 ページ
-
WB12
23 ページ
-
WB10ZG
20 ページ
-
WS7.0
6 ページ
-
LR19
6 ページ
-
WS12EX
8 ページ
-
WS10EX
8 ページ
-
WS58C
9 ページ
-
WS100M
24 ページ
-
WS60
12 ページ
-
WS7.5
41 ページ
-
WBT21
11 ページ
-
WS21
25 ページ
-
WBT61
7 ページ
-
WBT85
7 ページ
-
WS85
22 ページ
-
WS61
22 ページ
-
WS19KT
11 ページ
-
WS19KT
16 ページ
-
WS17KT
16 ページ
-
WS12
39 ページ
-
WS10
36 ページ
-
WS10ZG
36 ページ
-
WS10SG
36 ページ
-
WS42C
8 ページ
-
WS42
10 ページ
-
WS31C
8 ページ
-
WS31
10 ページ
-
PTM27
10 ページ
-
ASM Product Overview
40 ページ