グループ: Angst+Pfister
カタログの抜粋

Features □ Supply voltage: 1.7 to 5.5V(Vdd) 1.2 to 5.5V(Vddio) □ 1.4MPa pressure range □ 2.2ms fastest conversion time □ Standby current <0.1pA □ I2C and SPI interfaces □ Calibrated and temperature compensated Application Examples □ Sport watch □ Diving watch □ Smart watch Descriptions The PBM220 is a new generation of high resolution digital barometer. The PBM220 is a digital pressure sensor which consists of a MEMS piezoresistive pressure sensor and a signal conditioning ASIC. The ASIC include a 24bits sigma-delta ADC, OTP memory for calibration data, and serial interface circuits. The PBM220 could provide both I2C and SPI interface to communicate with microcontroller. Pressure calibrated and temperature compensated were key features of the PBM220. The data stored in OTP memory could be used to calibrate the PBM220. The calibration procedure should be implemented by an external microprocessor. The PBM220 is low power and supply voltage designed and suitable for portable devices or battery-supplied ones. The PBM220 is designed for water resistant applications. Ordering information Competitive sensor & power supply solutions worldwide
カタログの1ページ目を開く
Competitive sensor & power supply solutions worldwide
カタログの2ページ目を開く
1 Functional Block and Pin Descriptions Competitive sensor & power supply solutions worldwide
カタログの3ページ目を開く
Competitive sensor & power supply solutions worldwide
カタログの4ページ目を開く
4 Application Information Owing to state of the art, the PBM220 build a new standard of digital barometer. A 24bits sigma-delta ADC and a MEMS pressure sensor are integrated in a LGA substrate. Pressure calibrated and temperature compensated were key features of the PBM220. The PBM220 is low power and supply voltage designed and suitable for portable devices or battery-supplied ones. The data stored in OTP memory could be used to calibrate the PBM220. The calibration procedure should be implemented by a external microprocessor. By I2C or SPI interface, you can get the calibration data...
カタログの5ページ目を開く
5 Control registers Table 5.1 control registers Reg 0xF6-0xF8 Data_out: 24 bits ADC output data Reg 0xF4 OSR<1:0>: 00:1024X, 01:2048X, 10:4096X, 11:8192X Measurement_control<5:0>: 101110, indicate a temperature conversion. 110100, indicate a pressure conversion. Reg 0xE0 Softreset : Write only register. If set to 0xB6, will perform a power on reset sequence. Auto returned to 0 after the soft reset completed. Reg {0xF1, 0xD0, 0xBB:0xAA} Calibration Registers : Total 20bytes calibration registers used for sensor calibration. Reg 0x6B PartID: 8 bits Part ID, the default value is 0x42. Reg...
カタログの6ページ目を開く
Table 5.2 Summary of instructions Competitive sensor & power supply solutions worldwide
カタログの7ページ目を開く
Figure 6.1 SPI timing diagram The falling edge of CSB, in conjunction with the rising edge of SCLK, determines the start of framing. Once the beginning of the frame has been determined, timing is straightforward. The first phase of the transfer is the instruction phase, which consists of 16 bits followed by data that can be of variable lengths in multiples of 8 bits. If the device is configured with CSB tied low, framing begins with the first rising edge of SCLK. The instruction phase is the first 16 bits transmitted. As shown in Figure 5.2, the instruction phase is divided into a number of...
カタログの8ページ目を開く
Data follows the instruction phase. The amount of data sent is determined by the word length (Bit W0 and Bit W1). This can be one or more bytes of data. All data is composed of 8-bit words. Data can be sent in either MSB-first mode or LSB-first mode (by setting ‘LSB_first’ bit). On power up, MSB-first mode is the default. This can be changed by programming the configuration register. In MSB-first mode, the serial exchange starts with the highest-order bit and ends with the LSB. In LSB-first mode, the order is reversed. (Figure 6.3) CSB \I SDIO DON'T CARE \ R/W W1 | W0 | A12 | A11 | A10 |...
カタログの9ページ目を開く
Table 7.2 Electrical specification of the I2C interface pins The I2C interface protocol has special bus signal conditions. Start (S), stop (P) and binary data conditions are shown below. At start condition, SCL is high and SDA has a falling edge. Then the slave address is sent. After the 7 address bits, the direction control bit R/W selects the read or write operation. When a slave device recognizes that it is being addressed, it should acknowledge by pulling SDA low in the ninth SCL (ACK) cycle. At stop condition, SCL is also high, but SDA has a rising edge. Data must be held stable at SDA...
カタログの10ページ目を開く
*T\Lr::r\_Ai:: xxjcxn DATA ACK START ADDRESS R/W ACK condition DATA ACK STOP Competitive sensor & power supply solutions worldwide
カタログの11ページ目を開く
8.3.2 Sensor orientation relative to the tape Competitive sensor & power supply solutions worldwide
カタログの12ページ目を開く
Competitive sensor & power supply solutions worldwide
カタログの13ページ目を開く
Office Germany: Pewatron Deutschland GmbH EdisonstraEe 16 D-85716 UnterschleiEheim Phone +49 89 374 288 87-0 info.de@pewatron.com PEWATRON 5ENS0R5 • POWER SOLUTIONS Geometrical sensors Sensor elements Thorsten Ravagni Phone +49 60 479 53 627 thorsten.ravagni@pewatron.com Sales Other Countries / Product Management Pressure Sensors Gas sensors / Gas sensor modules Load cells Dr. Thomas Clausen Phone + 41 44 877 35 13 thomas.clausen@pewatron.com Flow / Level / Medical products Linear position sensors Angle sensors Eric Letsch Phone + 41 44 877 35 14 eric.letsch@pewatron.com Accelerometers /...
カタログの14ページ目を開くAngst+Pfister Sensors and Power AGのすべてのカタログと技術パンフレット
-
SQ-UST_L_0105-01
4 ページ
-
SQ-UST_L_0104-01
4 ページ
-
SQ-UST_L_0103-01
4 ページ
-
SQ-UST_L_0003-01
3 ページ
-
SQ-UST_L_0002-01
3 ページ
-
SQ-UST_L_0001-01
3 ページ
-
PFLOW Series
5 ページ
-
Model PFLOW3000 Series
16 ページ
-
Model PFLOW2001 Series
14 ページ
-
PZA-MC25-N/P
2 ページ
-
PEWA100
9 ページ
-
HLP-80H series
5 ページ
-
HLP-40H series
5 ページ
-
HBG-60P series
6 ページ
-
UHP-750 series
6 ページ
-
XLG-50 seri es
9 ページ
-
DAP-04 series
8 ページ
-
POB-30 series
11 ページ
-
RHP-1U Rack System
9 ページ
-
RFP-M8M4-5A
5 ページ
-
RFP-M5M3-3A
4 ページ
-
RFP-M2M3-3A
4 ページ
-
RFP-M1M3-3A
4 ページ
-
NCL CL1 01
4 ページ
-
IRL RGB 01
4 ページ
-
IRL CL2 01
4 ページ
-
MSR385WD
3 ページ
-
MSR145WD
3 ページ
-
MSR 145
3 ページ
-
M2029
3 ページ
-
MSR165
3 ページ
-
CRM102.1
33 ページ
-
CRM200
39 ページ
-
CRM100
37 ページ
-
FPM
4 ページ
-
FGN
4 ページ
-
FPN
4 ページ
-
PBM220 series
15 ページ
-
PBM210-A20K Series
14 ページ
-
STX Series – Model 13A
11 ページ
-
CCD Series – Model 54D
20 ページ
-
APB2Series
5 ページ
-
AP4Series
5 ページ
-
AP2Series
5 ページ
-
PHPS-7500 OEM
6 ページ
-
PPCP3-M1
10 ページ
-
AG4Series
6 ページ
-
AG2Series
5 ページ
-
New Pewatron brochure
11 ページ
-
GST220A
4 ページ
-
GSM40B
6 ページ
-
GSM36B
4 ページ
-
GSC25E
5 ページ
-
TDR-480
5 ページ
-
GC120
4 ページ
-
HDR-30
5 ページ
-
GSM220A
6 ページ
-
EPP-400
5 ページ
-
ENP-120
5 ページ
-
ENC-120
6 ページ
-
ATX-100
4 ページ
-
RPS-200
7 ページ
-
APBR30X75
2 ページ
-
APBR30X60
2 ページ
-
APBR 30X50 MM
2 ページ
-
PSB54/16
2 ページ
-
PSB54/14
2 ページ
-
PSB36T/16
2 ページ
-
PSB35T/12
2 ページ
-
PSB25T/16
2 ページ
-
PSB25T/12
2 ページ
-
PSB21/12
2 ページ
-
PSB 21
2 ページ
-
AD-Series
16 ページ
-
DMU11
3 ページ
-
HDR-30 series
5 ページ
-
DMU30-01
25 ページ
-
DMU30
3 ページ
-
DKA30 serie s
2 ページ
-
DCW12
2 ページ
-
DCW05
2 ページ
-
EH - EF 80 C/P/K
3 ページ
-
7S Series
3 ページ
-
Model CE36M
3 ページ
-
EX 80 A
3 ページ
-
UFO
3 ページ
-
UFO-M2
3 ページ
-
Dummy DC-Motoren
2 ページ
-
GC30E
3 ページ
-
RPS-400
11 ページ
-
GC 330
4 ページ
-
EL30
3 ページ
-
EA PROFIBUS
7 ページ
-
EAMW
3 ページ
-
AAM58
4 ページ
-
EAM36
3 ページ
-
CARBONOXY25
2 ページ
-
CARBONDIO-%
2 ページ
-
FCX-ML25-EXTERN-CH
14 ページ
-
FCX-MC25-CH
3 ページ
-
FCX-MC05-CH
3 ページ
-
FCX-TR0025
4 ページ
-
LP-10HA
3 ページ
-
FCX-UC-CH
9 ページ
-
901.1-EX
5 ページ
-
FC22
3 ページ
-
MILLINEWTON
3 ページ
-
PFLOW10U-2210
5 ページ
-
901.1
5 ページ
-
HX-EP
6 ページ
-
VQ548MP & MP-7217
5 ページ
-
Air quality sensing
6 ページ
-
Tailor-made
10 ページ
-
RAZTEC
13 ページ
-
The SGX-SureCO
3 ページ
-
930 Climair
5 ページ
-
MSP-600 600W AC/DC
5 ページ
-
Pewatron_Flyer_EN
8 ページ