
カタログの抜粋

AMETEK PROCESS INSTRUMENTS PRODUCT DATA SHEET Hkey benefits • Reliable performance • Internal verification on process gas • Fast response • Few interferences • No process temperature of pressure compensation required • Wide-range moisture ^ APPLICATIONS • Catalytic reforming • Moisture in olefins • Moisture in natural gas Hkey markets • Natural gas • Petrochemical • Refinery • Chemical 5000 Moisture Analyzer Fast, reliable ppmv moisture measurement The versatile 5000 is a highly sensitive moisture analyzer for process applications where the continuous, reliable measurement of moisture in vapors and gases is required. The analyzer measures moisture on-line by monitoring the vibrational frequency change of a hygroscopically sensitized quartz-crystal that is exposed alternately to wet sample and dry reference gas for 30 second periods. The reference gas is sample gas passed through a molecular sieve dryer to remove virtually all its moisture content. Many moisture analyzers are susceptible to attack by the process stream. Unsaturated hydrocarbons, compressor oils, oxygen, carbon dioxide, and others can permanently damage or destroy trace moisture sensors. Even worse, a fouled sensor can become completely unresponsive to moisture, yet continue to give an output, which could leave your process unmonitored. The 5000's unique differential measurement principle, combined with continuous diagnostics, ensures reliable performance in critical moisture applications. Field unit The field unit is explosion-proof and is certified to comply with numerous international standards. It contains a sample cell, switching valves and associated electronic circuits mounted internally and a flowmeter, flow control valves and back pressure regulator mounted externally. Controller Designed for use in industrial areas, the controller is available with several standard and optional certifications. It provides all control and data processing, as well as a keypad and display interface. Outputs include RS-485 bidirectional serial data, two fully configurable 4-20 mA analog signals, and three configurable alarms. It can be separated from the field unit by up to 600 m (2000 ft). External dryer The external dryer supplies the analyzer with reference gas, by using a molecular sieve to dry the actual process gas.
カタログの1ページ目を開く
PRODUCT DATA SHEET PERFORMANCE SPECIFICATIONS Ranges SALES, SERVICE & MANUFACTURING WORLDWIDE SALES AND SERVICE LOCATIONS Canada - Alberta 2876 Sunridge Way NE Calgary AB T1Y 7H9 Tel: +1 403 235 8400 Fax: +1 403 248 3550 © 2018, by AMETEK, Inc. All rights reserved. Printed in the U.S.A. F-0129 Rev 6 (1018) One of a family of innovative process analyzer solutions from AMETEK Process PROCESS INSTRUMENTS Instruments. Specifications subject to change without notice.
カタログの2ページ目を開くAMETEK Process Instrumentsのすべてのカタログと技術パンフレット
-
NATURAL GAS SOLUTIONS
11 ページ
-
Dew Point Tester
2 ページ
-
HAG Sampling Probe
2 ページ
-
Ranarex Gravitometer
2 ページ
-
Dew Point Testers
2 ページ
-
5000 Sample System
2 ページ
-
WDG 1200 1210 Insitu
2 ページ
-
CEM O2 TM
2 ページ
-
CEM Humox
2 ページ
-
CEM O2 Analyzer
2 ページ
-
WDG-HPIIC
2 ページ
-
CG1000
2 ページ
-
CMFA-P 2000
2 ページ
-
ta5000 Gas Analyzers
2 ページ
-
ta3000 Gas Analyzers
2 ページ