Data Sheet DS/TTR200-EN Rail mounted Temperature Transmitter TTR200 HART, Pt100 (RTD), thermocouples, Electrical isolation Input - Resistance thermometer - Thermocouples - Resistance-type transmitters - Voltages, mV voltages Output - 4 ... 20 mA, HART Measurement deviation - 0.1 K Sensor error adjustment Continuous sensor monitoring and selfmonitoring - Two function LEDs - Supply voltage monitoring - Wire break and corrosion monitoring in accordance with NE 89 Device safety in accordance with NE 53 SIL2 acc. to IEC 61508 Approvals for explosion protection - ATEX, IECEx, Zone 0 - FM / CSA Configuration - DTM - EDD Contents
カタログの1ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 3 1 Specifications Change from one to two columns 1.1 Input 1.1.1 Resistance thermometers/Resistors Resistance thermometer Pt100 in accordance with IEC 60751, JIS C1604-81, MIL-T- 24388, Ni in accordance with DIN 43760, Cu Resistance measurement 0 … 500 Ù 0 … 5000 Ù Sensor connection type Two-, three-, four-wire circuit Connecting cable Maximum sensor line resistance (RW) for each line 50 Ù according to NE 89 (January 2009) Three-wire circuit: symmetrical sensor line resistances...
カタログの3ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 4 2 General information Change from one to two columns CE Marking The TTR200 meets all requirements for the CE mark in accordance with IEC 61326 (2006) Electrical isolation 3.5 kV DC (approx. 2.5 kV AC) 60 s, input to output MTBF time 28 years at 60 °C ambient temperature Input filter 50 / 60 Hz Switch-on delay < 10 s (Ia 3.6 mA during starting cycle) Warm-up time 5 minutes Ramp-up time t90 400 … 1000 ms Rate updated 10/s, independent of sensor type and sensor circuit Output...
カタログの4ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 5 Change from one to two columns 2.6 Measuring accuracy Includes linearity deviation, reproducibility/hysteresis at 23 °C (73.4 °F) ± 5 K and 20 V supply voltage Information on measuring accuracy corresponds to 3 ó (Gaussian distribution) Input element Standard Sensor Measuring range limits Minimum span Digital measuring accuracy (24-bit A/D converter) D/A measuring accuracy 1) (16-bit DA) Resistance thermometer/resistor IEC 60 751 Pt10 Pt50 Pt100 Pt200 Pt500 Pt1000 (a=0,003850)...
カタログの5ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 6 2.7 Operating influences The percentages refer to the configured measuring span. Supply voltage influence/load influence: within the specified limits for the voltage/load, the total influence is less than 0.001 % per volt Common-mode interference: no influence up to 100 Veff (50 Hz) or 50 V DC Ambient temperature influence: based on 23 °C (73.4 °F) for ambient temperature range -40 ... 85 °C (-40 ... 185 °F) Sensor Influence of ambient temperature per 1 °C (1.8 °F) deviation to...
カタログの6ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 7 Kommunikation 3 Communication Change from one to two columns 3.1 Configuration parameters Measurement type Sensor type, connection type Error signaling Measurement range General information, e.g., TAG number Damping Signal simulation of output For additional information, see Section 8, "Order form configuration" Write protection Software write protection Diagnostic information in accordance with NE 107 Sensor error (wire break or short circuit) Device error Over/under alarm...
カタログの7ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 8 4 Electrical connections Fehler! Verweisquelle konnte nicht gefunden werden. A00203 12 ... 30 / 42 V DC + 11 - 4 ... 20 mA TTR200 + 11 PWR ERR OFF ON 1 2 - 1 2 3 4 5 6 A 4 2 2 2 1 1 1 1 1 1 4 3 3 3 3 3 3 2 1 2 3 4 5 6 + - 7 2 3 + - 8 9 2 3 Fig. 3 1 Potentiometer, four-wire circuit 2 Potentiometer, three-wire circuit 3 Potentiometer, two-wire circuit 4 RTD, four-wire circuit 5 RTD, three-wire circuit 6 RTD, two-wire circuit 7 Voltage measurement 8 Thermocouple 9 Terminal 11:...
カタログの8ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 9 Bestellangaben 6 Ordering information Main order number Add. order no. Version number 1 - 6 7 8 9 10 11 XX TTR200 rail-mounted temperature transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation TTR200 X X X X X XX Explosion protection Without explosion protection Y 0 ATEX intrinsic safety type of protection: Zone 0: II 1 G Ex ia IIC T6, zone 1 (0): II 2 (1) G Ex [ia] ib IIC T6, Zone 1 (20): II 2 G (1D) Ex [iaD] ib IIC T6 E 1 ATEX non-sparking type of protection:...
カタログの9ページ目を開く
Rail mounted Temperature Transmitter TTR200 DS/TTR200-EN HART, Pt100 (RTD), thermocouples, Electrical isolation 10 7 Ex relevant specifications Change from one to two columns The TTR200 complies with the requirements of ATEX Directive 94/9/EC. 7.1 TTR200-E1, Intrinsic Safety ATEX Explosion protection Approved for use in Zone 0 and 1 Designation II 1G Ex ia IIC T6 (Zone 0) II 2(1)G Ex [ia] ib IIC T6 (Zone 1 [0]) II 2G(1D) Ex [iaD] ib IIC T6 (Zone 1 [20]) EC type-examination test certificate PTB 05 ATEX 2017 X 7.2 TTR200-H1, Intrinsic Safety IECEx Designation Ex ia IIC T6 Ex [ia] ib IIC T6 Ex...
カタログの10ページ目を開く
ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/temperature The Company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (04.2010) © ABB 2010 3KXT241001R1001 DS/TTR200-EN Rev. B ABB Limited Salterbeck Trading Estate Workington, Cumbria CA14 5DS UK Tel: +44 (0)1946 830 611 Fax: +44 (0)1946 832 661 ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Automation Products GmbH...
カタログの12ページ目を開くABB Measurement & Analyticsのすべてのカタログと技術パンフレット
-
ProKiln GAC400
24 ページ
-
AV1 and AV2
24 ページ
-
OriMaster FPD500
24 ページ
-
AquaProbe FEA200
16 ページ
-
FTPA2000-HP260
4 ページ
-
266HSH and 266NSH
40 ページ
-
SCK
20 ページ
-
INDI-BOY DSP
8 ページ
-
9QGPS4500
8 ページ
-
9QGPS3100P
12 ページ
-
9QGPS2960
12 ページ
-
9QGPS2625
8 ページ
-
Ultrasonic level LST400
12 ページ
-
MB3600-HP10
5 ページ
-
MB3600-CH10
8 ページ
-
ACF5000
16 ページ
-
Magnos28
10 ページ
-
Dynamic QR Code
4 ページ
-
EL3060
8 ページ
-
HP30
4 ページ
-
Aztec ATS430
12 ページ
-
LMS200
12 ページ
-
PGC5000
8 ページ
-
LGR-ICOS 927S
4 ページ
-
Recording and Control
20 ページ
-
TZIDC and TZIDC-200
8 ページ
-
ProcessMaster FEP610
8 ページ
-
ALSCAN Brochure
6 ページ
-
MR Series
2 ページ
-
Emission Monitoring
8 ページ
-
Aztec 600 Iron Analyzer
12 ページ
-
ABB product catalog
32 ページ
-
process photometer
6 ページ