Data Sheet D-NO-SMA_2 Analytical Instruments Smart Analyzer 90 Type SMA Type SMA Smart Analyzer 90 .. Oxygen Only or Optional Oxygen and Combustibles .. Rugged Industrial Design .. Easy Installation and Start-up .. Highly Accurate Sensors .. Simplified In-house Maintenance .. Diagnostics and Alarming .. Patented Close Coupled Sample System .. Process Temperature Measurement .. Standard Combustion Efficiency Calculation .. Automatic Sensor Calibration-Standard .. Calibration Verification .. Distinctive Operator Interface .. Optional Filter Blowback .. High Temperature Operating Range .. Optional Dual Filtration System .. Probe & Cable Length Options .. Inherent Flashback Protection
カタログの1ページ目を開く
Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 2 SMA Smart Analyzer 90 The Type SMA Smart Analyzer 90 is a combustion analyzer. It continuously samples and analyzes industrial flue gases. The Type SMA1 Smart Analyzer 90 monitors oxygen O2 only. The Type SMA2 Smart Analyzer 90 monitors both O2 and carbon monoxide equivalent (COe). Product Overview The Type SMA Smart Analyzer 90 is a microprocessor based industrial grade combustion analyzer that continuously samples and analyzes industrial flue gases. The analyzer is designed for use on gas, oil or coal fired combustion...
カタログの2ページ目を開く
3 Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 After the process gas is analyzed by the sensors, it is combined with the aspirating air and is sent back into the duct through the aspirator exhaust filter. Electrical outputs from the sensors are fed through the interconnecting flexible cable to the electronics assembly for interpretation. Electronic Assembly The NEMA 4 electronics assembly provides the microprocessor based architecture and overall intelligence necessary to monitor sensor calibrations, field input/ output (I/O) signals and the operator interface. The...
カタログの3ページ目を開く
Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 4 SUGGESTED MOUNTING (BY CUSTOMER) OPTIONAL MOUNTING TO AN EXISTING 3 OR 4 in. FLANGE SECTION A-A DUCT WALL THE DIAMETER OF THE HOLE THROUGH THE DUCT WALL MUST EQUAL THE FULL O.D. OF THE 2 in. ANSI NPS NIPPLE. INSULATION 2 in. SCH 40 ANSI NPS NIPPLE 3 in. ANSI NPS CLASS 150 PIPE FLANGE 4 in. ANSI NPS CLASS 150 PIPE FLANGE 6.00 152.40 MIN 90 ASPIRATOR SUCTION PRESSURE PORT ansamlyazretr HOT SURFACE CAUTION AIR SUPPLY PORT 207 kPa (30 PSIG) TEST GAS PORT 12.00 304.80 CABLE ASSEMBLY 6638420_1_ 7.00 177.80 13.13 333.50 4.60 116.80...
カタログの4ページ目を開く
5 Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 Figure 3 - Standard and High Temperature Probe PROBE PROBE SECONDARY FILTER FLOPPY FILTER TP24003A FLOPPY FILTER CERAMIC PROBE STANDARD PROBE WITH FILTER STANDARD PROBE WITH OPTIONAL DUAL FILTER OPTIONAL HIGH TEMPERATURE PROBE WITH FILTER FLOPPY FILTER
カタログの5ページ目を開く
Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 6 TP24054D SYSTEM FAULT ALARM ACK SELECT CAL CONFIG ENTER VAR SETUP PREV SCREEN NEXT SCREEN 3.25 82.55 2.94 74.55 6.50 165.10 12.53 318.26 TERMINATION CHAMBER DOOR 17.45 443.10 18.00 457.20 18.75 476.25 1.91 48.54 4.38 111.12 0.43 10.79 NOMINAL VIEWING HEIGHT 1500 mm (59 in.) FROM FLOOR TO CENTERLINE OF DISPLAY 0.65 16.56 2.13 53.98 7.00 177.80 MINIMUM CABLE BEND CABLE ASSEMBLY 6638420_1_ 7.14 mm (0.281 in.) WIDE X 19.05 mm (0.750 in.)LNG MOUNTING SLOTS 16.15 410.08 CLEARANCE REQ’D TO OPEN DOOR CUSTOMER SIGNAL WIRING CONDUIT 3/4...
カタログの6ページ目を開く
7 Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 DX BX 2 2 2 2 2 2 2 2 Figure 5 - Analyzer Installation Overview
カタログの7ページ目を開く
Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 8 ENGINEERING SPECIFICATIONS Variable Analog Output Ranges O2 span Minimum 0 to 5% Maximum 0 to 25% COe span Minimum 0 to 200 ppm (0.00 to 0.02%) Maximum 0 to 20000 ppm (0.00 to 2.00%) Temperature Zero -46º to 1371ºC (-50º to 2500ºF) Temperature span Minimum 260ºC (500ºF) Maximum 1649ºC (3000ºF) Display Screen Accuracy O2 ± 2.5% or reading (0.1 to 25.0%) COe ± 20 ppm (from 200 to 1000 ppm) ± 2% of span (from 1000 to 20000 ppm) Temperature (Thermocouple ± 3.3ºC (±6.0ºF) type: E, J, K or T) (Thermocouple ± 5.5ºC (±10ºF) type: R or...
カタログの8ページ目を開く
9 Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 Output Signals Four Analog1 1 to 5 VDC or 4 to 20 mA AO1: Process O2 (isolated2 or non-isolated) AO2: Process COe AO3: Inlet/outlet temperature AO4: Combustion efficiency Six isolated digital3 Form C relay contacts rated DO1: Process O2 for 2 A at 120/240 VAC, DO2: Process COe 50/60 Hz or 24 VDC DO3: Process temperature alarm DO4: Combustion efficiency alarm DO5: Analyzer fault alarm DO6: Calibration in progress Maximum Analog Output Loading Voltage Mode Not <250 kW and not > 600 mH Current Mode Not > 600 W and not > 600 mH...
カタログの9ページ目を開く
Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 10 Approvals/Certifications Factory Mutual Approved against flashback into duct. Factory Mutual Approved for use in Class I, Division 2, groups A,B,C and D and for use in Class II, Division 2, groups F and G. Canadian Standard Certified for use in ordinary Association nonhazardous locations. CE Mark Complaint EMC Directives 89/336/EEC & 73/23/EEC EMC Standards EN50081-2, EN50082-2 & EN61010-1 Notes: 1. AO2 (COe) defaults to 4 mA or 1.0 VDC when a Type SMA1 analyzer is installed. AO3 (inlet/outlet temperature) and AO4 (combustion...
カタログの10ページ目を開く
Analytical Instruments Smart Analyzer 90 - Type SMA D-NO-SMA_2 12 The Company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (2.19.06) © ABB 2006 D-NO-SMA_2 ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com ABB Inc. 125 East County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 ABB Ltd Oldends Lane, Stonehouse Gloucestershire, GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 ABB Inc. 9716 S. Virginia St. Suite E...
カタログの12ページ目を開くABB Measurement & Analyticsのすべてのカタログと技術パンフレット
-
ProKiln GAC400
24 ページ
-
AV1 and AV2
24 ページ
-
OriMaster FPD500
24 ページ
-
AquaProbe FEA200
16 ページ
-
FTPA2000-HP260
4 ページ
-
266HSH and 266NSH
40 ページ
-
SCK
20 ページ
-
INDI-BOY DSP
8 ページ
-
9QGPS4500
8 ページ
-
9QGPS3100P
12 ページ
-
9QGPS2960
12 ページ
-
9QGPS2625
8 ページ
-
Ultrasonic level LST400
12 ページ
-
MB3600-HP10
5 ページ
-
MB3600-CH10
8 ページ
-
ACF5000
16 ページ
-
Magnos28
10 ページ
-
Dynamic QR Code
4 ページ
-
EL3060
8 ページ
-
HP30
4 ページ
-
Aztec ATS430
12 ページ
-
LMS200
12 ページ
-
PGC5000
8 ページ
-
LGR-ICOS 927S
4 ページ
-
Recording and Control
20 ページ
-
TZIDC and TZIDC-200
8 ページ
-
ProcessMaster FEP610
8 ページ
-
ALSCAN Brochure
6 ページ
-
MR Series
2 ページ
-
Emission Monitoring
8 ページ
-
Aztec 600 Iron Analyzer
12 ページ
-
ABB product catalog
32 ページ
-
process photometer
6 ページ