ProcessMaster FEP630 Electromagnetic flowmeter
1 / 92ページ

カタログの抜粋

ProcessMaster FEP630 Electromagnetic flowmeter - 1

—ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET ABB ProcessMaster FEP630 Electromagnetic flowmeter

カタログの1ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 2

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H — Measurement made easy The first choice for all industrial applications — EtherNet/IP, ProfiNet® • Minimize commissioning and Start-up • Configure the Device remotely • Take advantage of the in-built device driver (EDS for EtherNet/IP™, GSDML for ProfiNet®) reducing integration cost • Monitor your Process and the Flowmeter Status • Diagnose your Process and the Flowmeter Status • Verify the Flowmeter remotely — Diagnostics for real-life situations • To keep your process up and running • Gas bubble, partial filling or...

カタログの2ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 3

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H — ProcessMaster series ProcessMaster is available in two series – ProcessMaster 610 the good fit for everyday applications and ProcessMaster 630 the first choice for all process industry applications delivering best in class functionality and options. Applicability Good fit for everyday applications The first choice for all industrial applications Measuring medium minimum conductivity Measuring medium temperature ≤ PN 40 / Cl 300, option for high pressure Hazardous area Nominal diameter Liner material PTFE, Rubber, PFA,...

カタログの3ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 4

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H — … ProcessMaster series Features and Functions On-board Health Check ProcessMaster's in-built fingerprint technology helps to ensure Sensor and Transmitter Integrity without the need to remove the flowmeter from the process. The Check provides a pass / failed result based on a comparison of the current flowmeter status to a set of reference data. Diagnostics for real-life situations Detecting critical process conditions at an early stage helps reducing unscheduled downtime and maintenance. Clear text messages simplify...

カタログの4ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 5

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H Standard functionality Flowmeter sensor coil inductance A measurement of the flowmeter sensor coil inductance can be triggered. This enables to check for the flowmeter sensor coil integrity. Noise check / Grounding check This function allows checking for noise and proper electrical grounding of the device. While the check is in progress, no flow measurement can take place. Pre-requisites using the functionality: • Flowmeter sensor must be completely filled • No flow must occur in the flowmeter sensor Fingerprint The...

カタログの5ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 6

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H — … ProcessMaster series … Features and Functions Optional diagnostic functions The extended diagnostics functionality package contains the following functions. Gasbubble detection Gas bubbles in the measuring medium effect the flowmeter reading and the accuracy. Enhanced diagnostics feature the option for gas bubble detection to make the flow measurement most reliable. There is the option for a gas bubble alarm triggered once the actual gas bubble value exceeds the threshold configured. This alarm is shown in the HMI. The...

カタログの6ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 7

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H Filling function The optional filling function allows filling with filling times> 3 seconds. Filling quantity is configurable and the filling process can be started via the digital input (plug-in card). As soon as the filling quantity has been reached, the valve can be closed via the digital output. Filling quantity correction is calculated by measuring the overrun quantity. Additionally, the low flow cut-off can be configured if required. 1 Supply tank 2 Sensor 3 Start / stop fill operation (digital input through plug-in...

カタログの7ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 8

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H — Overview – models without hazardous area approval Sensor Integral mount design 1 Single-compartment transmitter housing Remote mount design 3 Flowmeter sensor, Design Level A (DN 3 to 2000) 2 Dual-compartment transmitter housing Figure 2: Designs Flowmeter sensor Model Integral mount design, remote mount design Measuring accuracy for liquids 0.4 % of the measured value, option for 0.3 % and 0.2 % of the measured value Permissible measuring medium temperature Tmedium Minimum conductivity > 5 µS/cm, (20 µS/cm for...

カタログの8ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 9

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H 1 Dual-compartment transmitter housing 2 Single-compartment transmitter housing Transmitter Model Integral mount design, remote mount design Cable length Maximum 200 m (656 ft), remote mount design only Power supply Current output: 4 to 20 mA active or passive (can be configured on-site) Digital output 1: passive, configurable as pulse, frequency or switch output Digital output 2: passive, configurable as pulse or switch output Additional outputs The transmitter has two slots which can be used to insert plug-in cards to...

カタログの9ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 10

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H — Overview – models with Ex protection Overview – The fast track to explosion protection device data These safety instructions related to explosion protection are valid in conjunction with the following test documentation and certificates: Scope Electrical connection and explosion protection data from chapter Operation in Zone 1, 21 on page 63 Operation in Zone 2, 22 on page 68 Operation in Zone 1, 21 on page 63 Operation in Zone 1, 21 on page 63 Operation in Zone 2, 22 on page 68 Operation in Zone 2, 22 on page 68 Version...

カタログの10ページ目を開く
ProcessMaster FEP630 Electromagnetic flowmeter - 11

PROCESSMASTER FEP630 ELECTROMAGNETIC FLOWMETER | DS/FEP630-EN REV. H ATEX / UKEX ATEX / UKEX CL I, ZN 1, AEx db eb mb [ia Ga] IIC T6…T1 Gb ZN 21, AEx tb [ia Da] IIIC T80°C...T165°C Db Canada, FM approval CL I, ZN 1, Ex db eb mb [ia Ga] IIC T6…T1 Gb Ex tb [ia Da] IIIC T80°C...T165°C Db 1) Single-compartment housing 2) Dual-compartment housing When Flowmeter is equipped with Ethernet Card (Ethernet Card availabe with Zone 2, Div. 2 only), the following Notes apply: 3) T4 instead of T6 4) T

カタログの11ページ目を開く

ABB Measurement & Analyticsのすべてのカタログと技術パンフレット

  1. ProKiln GAC400

    24 ページ

  2. AV1 and AV2

    24 ページ

  3. OriMaster FPD500

    24 ページ

  4. AquaProbe FEA200

    16 ページ

  5. FTPA2000-HP260

    4 ページ

  6. 266HSH and 266NSH

    40 ページ

  7. SCK

    20 ページ

  8. INDI-BOY DSP

    8 ページ

  9. 9QGPS4500

    8 ページ

  10. 9QGPS3100P

    12 ページ

  11. 9QGPS2960

    12 ページ

  12. 9QGPS2625

    8 ページ

  13. MB3600-HP10

    5 ページ

  14. MB3600-CH10

    8 ページ

  15. ACF5000

    16 ページ

  16. Magnos28

    10 ページ

  17. Dynamic QR Code

    4 ページ

  18. EL3060

    8 ページ

  19. HP30

    4 ページ

  20. Aztec ATS430

    12 ページ

  21. LMS200

    12 ページ

  22. PGC5000

    8 ページ

  23. LGR-ICOS 927S

    4 ページ

  24. ALSCAN Brochure

    6 ページ

  25. MR Series

    2 ページ

  26. ABB product catalog

    32 ページ

  27. process photometer

    6 ページ