CoriolisMaster FCB400, FCH400
1 / 104ページ

カタログの抜粋

CoriolisMaster FCB400, FCH400 - 1

—ME ASURE ME NT & AN AL YT ICS | D AT A SHE ET ABB CoriolisMaster FCB400, FCH400 Coriolis mass flowmeter

カタログの1ページ目を開く
CoriolisMaster FCB400, FCH400 - 2

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Measurement made easy High-precision measurement of mass and volume flow, density, temperature and concentration with just one device — Up to five modular I/Os • Optional plug-in cards • Automatic firmware update • Integrated solutions for filling operations and concentration measurement — SmartSensor • All digital solution • Measuring device intelligence located directly in the sensor • Lower pressure loss — Integrated VeriMass device verification and diagnosis • Predictive maintenance in the process • Extended...

カタログの2ページ目を開く
CoriolisMaster FCB400, FCH400 - 3

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Overview – models 1 Sensor (integral mount design, dual-compartment housing) 3 Sensor (remote mount design) 2 Sensor (integral mount design, single-compartment housing) Figure 1: Designs Sensor Model Integral mount design, remote mount design Measuring accuracy for liquids Mass flow* Volume flow* Measuring accuracy for gases* Permissible measuring medium temperature Tmedium Process connection Flange DIN 2501 / EN 1092-1 Threaded pipe connection conforming to DN 10 to 100 (⅜ to 4 in) Other connections Wetted material...

カタログの3ページ目を開く
CoriolisMaster FCB400, FCH400 - 4

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … Overview – models Figure 2: Transmitter with remote mount design Transmitter Chassis Integral mount design (see Figure 1, pos. 1 and 2), remote mount design. Cable length Maximum 200 m (656 ft), with remote mount design only Power supply Outputs in basic version Current output: 4 to 20 mA active or passive Digital output 1: passive, configurable as pulse, frequency or switch output Digital output 2: passive, configurable as pulse or switch output Additional optional outputs The transmitter has two slots in which plug-in...

カタログの4ページ目を開く
CoriolisMaster FCB400, FCH400 - 5

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — General data Device description SIL-functional safety The CoriolisMaster FCB400, FCH400 is the cost-effective and easy ABB mass flowmeter with a new modular transmitter. Verification in accordance with IEC 61508 2, route Component Type The CoriolisMaster FCB400, FCH400 operates in accordance with the Coriolis principle. The design offers the following benefits: • Space-saving, robust design. • Variety of process connections. • Modular, flexible output concept. Transmitter with digital signal processor (DSP) The...

カタログの5ページ目を開く
CoriolisMaster FCB400, FCH400 - 6

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … General data FillMass batch function Only for FCB450 / FCH450 Start Start of the filling process via field bus or digital input 3 Start / stop fill operation (digital input or field bus) 4 Fill valve 5 Filling tank State of the digital output for the fill valve Q Flow rate VO Valve open (filling started) VC Valve closed (fill quantity reached) t1 Valve closing time t2 Overrun time Figure 3: FillMass fill function The integrated FillMass fill function allows filling processes with filling times of > 3 seconds. For this...

カタログの6ページ目を開く
CoriolisMaster FCB400, FCH400 - 7

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N Concentration measurement DensiMass Only for FCB450 / FCH450 The transmitter can calculate the current concentration from the measured density and temperature using concentration matrices. The following concentration matrices are preconfigured in the transmitter as standard: • Concentration of sodium hydroxide in water • Concentration of alcohol in water • Concentration of sugar in water • Concentration of maize starch in water • Concentration of wheat starch in water In addition, the user can enter two user-defined...

カタログの7ページ目を開く
CoriolisMaster FCB400, FCH400 - 8

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … General data Enhanced Coriolis Control (ECC)function The Enhanced Coriolis Control (ECC)function has been specially developed for demanding applications, such as: • Liquids with gas phase • Liquids with rapidly changing densities • Fill operations with surge phases at the beginning or end • Liquids with high viscosity After the ECC function is activated, the device applies a particularly quick control algorithm to control the oscillating tubes in the device and therefore provide significantly better behavior in the...

カタログの8ページ目を開く
CoriolisMaster FCB400, FCH400 - 9

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — Flowmeter sensor VeriMass erosion monitor General installation conditions The integrated diagnosis function VeriMass allows the status of the meter tube to be monitored. This enables changes due to material erosion and the formation of deposits on the meter tube walls to be identified at an early stage. If the set limit value is exceeded, an alarm is triggered, for example via the programmable digital output or HART, depending on the configuration. The limit value for the erosion monitor can be set either automatically or...

カタログの9ページ目を開く
CoriolisMaster FCB400, FCH400 - 10

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N — … Flowmeter sensor Brackets and supports No special supports or damping are required for the device when the device is used and installed as intended. In systems designed in accordance with ‘Best Practice’, the forces acting on the device are already sufficiently absorbed. This is also true of devices installed in series or in parallel. For heavier devices, it is advisable to use additional supports / brackets on site. Doing this prevents damage to the process connections and piping from lateral forces. Please observe the...

カタログの10ページ目を開く
CoriolisMaster FCB400, FCH400 - 11

FCB400, FCH400 CORIOLIS MASS FLOWMETER | DS/FCB400/FCH400-EN REV. N For vertical installation in a riser, no special measures are required. B For vertical installation in a downpipe, a piping constriction or an orifice must be installed below the sensor. Doing this prevents the sensor from draining during the measurement. Gaseous measuring media Horizontal installation Observe the following points to avoid measuring errors: • Gases must be dry and free of liquids and condensates. • Avoid the accumulation of liquids and the formation of condensate in the meter tube. • During operation, there...

カタログの11ページ目を開く

ABB Measurement & Analyticsのすべてのカタログと技術パンフレット

  1. ProKiln GAC400

    24 ページ

  2. AV1 and AV2

    24 ページ

  3. OriMaster FPD500

    24 ページ

  4. AquaProbe FEA200

    16 ページ

  5. FTPA2000-HP260

    4 ページ

  6. 266HSH and 266NSH

    40 ページ

  7. SCK

    20 ページ

  8. INDI-BOY DSP

    8 ページ

  9. 9QGPS4500

    8 ページ

  10. 9QGPS3100P

    12 ページ

  11. 9QGPS2960

    12 ページ

  12. 9QGPS2625

    8 ページ

  13. MB3600-HP10

    5 ページ

  14. MB3600-CH10

    8 ページ

  15. ACF5000

    16 ページ

  16. Magnos28

    10 ページ

  17. Dynamic QR Code

    4 ページ

  18. EL3060

    8 ページ

  19. HP30

    4 ページ

  20. Aztec ATS430

    12 ページ

  21. LMS200

    12 ページ

  22. PGC5000

    8 ページ

  23. LGR-ICOS 927S

    4 ページ

  24. ALSCAN Brochure

    6 ページ

  25. MR Series

    2 ページ

  26. ABB product catalog

    32 ページ

  27. process photometer

    6 ページ