AquaProbe FEA200
1 / 16ページ

カタログの抜粋

AquaProbe FEA200 - 1

ABB MEASUREMENT & ANALY TICS | DATA SHEET AquaProbe FEA200 Insertion-type electromagnetic flow sensor with AquaMaster3 transmitter

カタログの1ページ目を開く
AquaProbe FEA200 - 2

— Measurement made easy Maximum performance, minimum hassle Suitable for permanent or temporary installation • total user flexibility Proven accuracy over wide operating flow range in both forward and reverse flow directions • enables accurate measurement Battery / Renewable power operation • optional 10-year battery life • no external power supply required • facilitates installation in remote location • ability to connect a solar panel or wind turbine AC powered with supercapacitor backup • continuous measurement even during power-down Optional built-in multi-speed, multi-channel,...

カタログの2ページ目を開く
AquaProbe FEA200 - 3

AQ UA P R OB E F E A200 I N SER T I ON FLOW S ENSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200-E N RE V. A — AquaProbe FEA200 AquaProbe FEA200 extends the capability of the ABB AquaProbe flowmeter by bringing together the proven AquaProbe flow sensor with the innovative AquaMaster3 transmitter. The high sensitivity of AquaProbe enables it to traverse the pipe to establish the flow profile and so identify hydraulic problems in complex systems or ensure maximum accuracy from an AquaProbe that has been installed in a non-ideal location. AquaProbe has been designed, in close consultation...

カタログの3ページ目を開く
AquaProbe FEA200 - 4

AQ UAPRO B E F E A200 I N SER T I ON FLOW SE NSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200- E N RE V. A AquaProbe FEA200 power options Mains power with super capacitor back-up • Mains-only option supplied with a built-in rechargeable super capacitor backup power source • The super capacitor can operate for up to 5 days without power (depending on operating conditions) • The super capacitor has recharge cycles greater than 10,000 and, with mains power, offers continuous SMS operation • In the event of mains interruption, continuous measurement is maintained and alarms reported via...

カタログの4ページ目を開く
AquaProbe FEA200 - 5

AQ UA P R OB E F E A200 I N SER T I ON FLOW S ENSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200-E N RE V. A — Logger facility Traditional techniques of counting pulses over a short logging interval leads to ‘quantization’ effects corresponding to whole numbers of pulses on logger graphs that is shown on Figure 3. AquaProbe FEA200 eliminates such effects, averaging digitally over the selected logging interval. Such high resolution data facilitates step testing, leak detection and water network analysis. 30 Access to the loggers and logger configuration is securityprotected by...

カタログの5ページ目を開く
AquaProbe FEA200 - 6

AQ UAPRO B E F E A200 I N SER T I ON FLOW SE NSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200- E N RE V. A — AquaMaster3 transmitter The AquaMaster3 transmitter provides a comprehensive display of all flow data, including forward and reverse flow totals, flow rate, pressure and time / date. If all the data is not required, the transmitter is configured easily to display only the required values, ensuring simple reading with no superfluous data. The two standard pulse outputs (forward and reverse flow direction) are compatible with the wide range of dataloggers used in the water...

カタログの6ページ目を開く
AquaProbe FEA200 - 7

AQ UA P R OB E F E A200 I N SER T I ON FLOW S ENSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200-E N RE V. A — Easy, low cost installation No matter what the location or installation requirements, AquaProbe provides a cost-effective solution. The flow sensor is fully submersible, enabling installation in flooded chambers. The AquaProbe is installed by means of a small valve tapping on the water supply pipeline, normally with the sensing head on the pipe center line. It may be located at the critical position (the mean velocity position) a distance of 1/8 of the pipe diameter away from...

カタログの7ページ目を開く
AquaProbe FEA200 - 8

AQ UAPRO B E F E A200 I N SER T I ON FLOW SE NSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200- E N RE V. A — Technical specification AquaProbe flow sensor Maximum flow The maximum velocity depends upon the actual insertion length. Typical insertion lengths are 0.125 and 0.5 x pipe diameter. The graph (Figure 7) is a guide* to the maximum allowable velocity for different insertion lengths. Protection IP68/NEMA6P (Indefinite submersion down to 10 m [30 ft.]) Weight <3.5 kg (7.7 lb) Accuracy Velocity ±2 % of Rate or ±2 mm/s (±0.08 in./s) whichever is the greater Volume Refer to ISO...

カタログの8ページ目を開く
AquaProbe FEA200 - 9

AQ UA P R OB E F E A200 I N SER T I ON FLOW S ENSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200-E N RE V. A AquaMaster3 transmitter Housing IP68 (NEMA 6P) Stainless steel housing in a Thermoplastic outer cover with window, encapsulated with polyurethane-based resin. Electrical connections IP68 plug & socket, mains cable (option) Mains supply (option) 85 to 285 V AC @ <3 VA Power requirement: <3 W Connection cable: <3 m (9.8 ft.) Mains power failure backup time: 5 days Renewable power (option) Solar or wind Input voltage range: • 6 to 22 V DC* Maximum input current: • 200 mA Backup...

カタログの9ページ目を開く
AquaProbe FEA200 - 10

AQ UAPRO B E F E A200 I N SER T I ON FLOW SE NSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200- E N RE V. A — …Technical specification Telemetry applications (option) GSM / SMS modem Frequency bands • Quad band: 850 / 900 / 1800 / 1900 MHz Functions • SMS auto report of flow and optionally, pressure logger data (typically 1 s or 1 min. average) • SMS report frequency: typically daily • SMS alarm reporting at time of event, for example power loss, limited to 1 per day • SMS flowmeter configuration • SMS flowmeter diagnosis • SMS total / tariff auto report GSM antenna (option) Quad band...

カタログの10ページ目を開く
AquaProbe FEA200 - 11

AQ UA P R OB E F E A200 I N SER T I ON FLOW S ENSOR WITH AQUAMASTE R 3 TR ANSMIT TE R  |  DS/FE A200-E N RE V. A Limits of upstream disturbance re nt ce e n n O li Minimum upstream straight length* For a measurement axial velocity Several 90° Coplanar Bends Several 90° Non-coplanar Bends Total Angle Convergent 18 to 36° Total Angle Divergent 14 to 28° Fully Opened Butterfly Valve Fully Opened Plug Valve upstream from the measuring cross-section *Expressed in multiples of the diameter of the conduit. Downstream from the measurement cross-section, the straight length must be at least equal to...

カタログの11ページ目を開く

ABB Measurement & Analyticsのすべてのカタログと技術パンフレット

  1. ProKiln GAC400

    24 ページ

  2. AV1 and AV2

    24 ページ

  3. OriMaster FPD500

    24 ページ

  4. FTPA2000-HP260

    4 ページ

  5. 266HSH and 266NSH

    40 ページ

  6. SCK

    20 ページ

  7. INDI-BOY DSP

    8 ページ

  8. 9QGPS4500

    8 ページ

  9. 9QGPS3100P

    12 ページ

  10. 9QGPS2960

    12 ページ

  11. 9QGPS2625

    8 ページ

  12. MB3600-HP10

    5 ページ

  13. MB3600-CH10

    8 ページ

  14. ACF5000

    16 ページ

  15. Magnos28

    10 ページ

  16. Dynamic QR Code

    4 ページ

  17. EL3060

    8 ページ

  18. HP30

    4 ページ

  19. Aztec ATS430

    12 ページ

  20. LMS200

    12 ページ

  21. PGC5000

    8 ページ

  22. LGR-ICOS 927S

    4 ページ

  23. ALSCAN Brochure

    6 ページ

  24. MR Series

    2 ページ

  25. ABB product catalog

    32 ページ

  26. process photometer

    6 ページ