Catalogue Testing Machines and Systems for textile materials
www.zwick.com
print switch display
Page / 35
Zwick - 41273, 5567, 82695
/ 35
See other catalogues for Zwick
Text version of the page
Zw/ck # Roell
Extensometers - Help for choice
Application Extensometers
Clamping th between clamping jaws
e specimen
by wrapping around plates or rollers
j_ i- i- ? e e e er e
t e t t te t
ì E 2 E E £ E e r o tr o l o o o Materials characteristics o o jjj ^ j2 <° j2 <° i. jjj
to be determined and £'£ « £> |?«> £ £ JJ $ «
......... £ ê ™x ox Sx rax
the related standards OE sa> -ia> Oa> >a> -ia>
Crosshead monitor
Macro
extensometer
Long sLioive
extensometer
Video
extensometer1' Laser
extensometer
Tensile modul
• EN ISO 10618 - y -- y -
• EN 12562, EN 13002-2, y • -- • -
+ • -- • -
EN 13003-2
Secant rigidity and
strain at max. force
• EN ISO 10319 -- - y y y
-- - У У У
Strain at x% of max. force
• ISO 283-1 - y -- y -
Strain at break
• ISO 283-1 - yyyy y
Strain at max. force and break
• EN ISO 10618 - y -- y -
• EN 12562, EN 13002-2, y • -- • -
EN 13003-2
+ • -- • -
• EN ISO 5079, ASTM D 38229, y - -- - -
ASTM D 3379
• EN ISO 2062, DIN 53834-2, y • • • • -
ASTM D 2256
• ASTM D 885, cords ------
• ASTM D 885, industrial fabrics y • • • • •
• ISO 6939, ASTM D 1578 y • • • • -
• ISO 3341 y • -- • -
• EN ISO 9163 y • • • • -
• EN 13844 ------
• EN ISO 13934-1, ASTM D 1682 y • • • • •
• EN 29073-3, EN 4606, EN 3342y • • • • •
• EN ISO 1421 y • • • • •
• EN 1492-1 ------
• EN 61067-2, EN 565 - O O y y y
• EN 919, ASTM D 4268, EN 892 ------
• EN 564 ------
+ О О • • -
- О О У У У
+ • -- • -
+ О О • • •
- О О • • •
- О О • • •
- О О У У У
- О О У У У
- - - У У У
- О О У У У
S - Suitable for this application
+ - Suitable for this application if the deflection in the specimen grips is max. 180°
O - Suitable for this application if there is no risk that the sensor arms get damaged due to specimen parts rebounding at specimen break • - Is used if a higher measuring accuracy without clamping influence is required. Mechanical measuring systems can only be used
if there is no risk that they get damaged at specimen break. When using contactless measuring systems, a specimen marking is required
1) The objectives of the video measuring system cannot be changed during the test. Optionally the determination of variations in width are also possible
29
DirectIndustry's Virtual Technical Library: PDF Catalogue | Technical Documentation | Brochure | Manual | Industrial directory | Specifications | Characteristics
Search Go
Contents table
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35