Test devices for cement,gypsum and lime
Le Chatelier Water Bath Free LimeDetermination Device
Device to determine the stability of
cement which may change when
expanding during hydration. For this
purpose up to 16 specimen bars
can be stored in a bath of boiling
water or water vapor. The heating
cycle – e.g. heating up to 100ºC
within 30 min and keeping this
temperature constant for more than
3 h – is regulated automatically and
with a high accuracy (accurate to
0.1ºC). Setting time and setting
temperature may vary according to
the requirements in question.Easy and
industrial safe handling. >
Automatic VICATNeedle Apparatus
Device to determine theconcentration of free lime in cement
or cement clinker. For this purpose
the conductivity of a cement
solution in hot glycol is measured.The menu-guided test sequenceallows an easy and safe handling
and short test times. The test
results are available more quickly
compared to other methods, thus
allowing also a quicker correction
of the
industrial furnace operation and the
burning process. Apparatus to determine the settingtime on up to 8 specimens irre-
spective from each other. The time of
begin and end of the setting process
of cement, gypsum or mortar is
measured. The penetration depth
of the Vicat
industrial needle into the specimen
is measured, evaluated and saved
according to 3 different methods.
The measurements may be carried
out in any order at any of the 8
available spots thus making optimum
use of the specimen surface but
considering the conditions set by
the different standards. >
Automatic Blaine Apparatus
Apparatus to determine the specificsurface of cement and other
powdered materials. The time
required by a certain air volume
to penetrate a powder bed is
measured in accordance with
EN 196-6.
Measurement, test sequence
control and evaluation are
automatically performed. >
Le Chatelier Water BathFree Lime Determination DeviceAutomatic Blaine Apparatus
Automatic VICAT Needle Apparatus 13