You may also be interested in
Linear actuator, Electric cylinder, Worm gear screw jack, Screw jack, Worm gear reducer
Text version of the page
Selection - Checklists - Calculations
© by ZIMM Austria 2009
19
Length Calculation, Standing Version S - Protective Tube SRO
1) Basic length of protective tube
without cap - add another 5 mm
to the overall length of the
protective tube to include the
cap thickness.
2) If a shorter stroke than specified is
required, fit the limit switches and
the lubrication strip on two different
sides (fitting location)!
3) Limit switches ES are always in
combination with rotation protection
VS (VS is included in the extension),
with escape protection AS as from
Z-250.
Protective tube extension for S version
Z-2
47
15
70
92
Z-5
46
15
73
94
Z-10
49
20
72
92
Z-25
53
20
72
96
Z-35
57
30
86
-
Z-50
62
30
82
-
Z-50/Tr50
62
30
82
-
Z-100
82
30
62
-
Z-150
87
30
62
-
Z-2 to Z-150:
Min. stroke with limit switch ES
Min. stroke with ES and lubrication strip SL
Attention: Minimum stroke with limit switch ES2):
Z-2
53
123
Z-5
50
120
Z-10
51
121
Z-25
51
121
Z-35
41
111
Z-50
42
112
Z-50/Tr50
42
112
Z-100
42
112
Z-150
42
112
Protective tube extension for S version
Z-250
87
30
46
-
Z-350
97
35
51
-
Z-500
151
40
40
-
Z-750
152
40
40
-
Z-1000
152
40
40
-
Z-250 to Z-1000:
Min. stroke with limit switch ES
Min. stroke with ES and lubrication strip SL
Attention: Minimum stroke with limit switch ES2):
Z-250
47
117
Z-350
42
112
Z-500
46
116
Z-750
46
116
Z-1000
46
116
Z-2 to Z-150:
Tr basic length1)
Escape/rotation protection AS/VS
Limit switch ES3)
ES3) and hinged bearing plate KAR
Z-250 to Z-1000:
Tr basic length1)
Escape protection AS
Limit switch ES3)
ES3) and hinged bearing plate KAR
|
|