Catalog excerpts
TIL04_21-GB (21.07.06) Subjekt to technial modifications 8. 8.1.4-GB Transformer based controller for 1~ motors Controller with automatic step switching for voltage controllable fans Type: RASE9G Examples of applications for automatic control of single phase fans in 5-steps Speed control of one or more 1~ fans e. g. in: heat exchangers (as warm-air heaters), hoods, ventilation of rooms. In combination wit a 5-step thermostat the fan speed is automatically controlled in 5steps. Mechanical thermostat type SRE5G (Part. No. 380003), electronic thermostat type SRHE5A-M (Part.No. 325001). Equipment Enclosed version IP 54 Transformer based controllers for voltage controllable 1~ fans • Step switch Step 1-4: manual setting in 4 steps (65-135-170-230 V) AUTO: automatic 5-step switch over by separate thermostat • Integrated power-on lamp • line fuses for thermostat cable construction side • Automatic switch-on after power failure • For motors with thermocontacts we recommend that each fan is equipped with a separate motor protection device type S-ET10 Technical data - Line voltage 1~ 230 V, 50/60 Hz - Output voltage 65 V - 110 V - 135 V - 170 V - 230 V - Max. ambient temperature + 40° C - Max. load additional contact 1 A - Protection class IP54 - Housing top ABS plastic light grey RAL7035 bottom aluminium die casting Type Part-No. Rated current Max. line fuse Max. heat dissipation Weight RASE9G 302034 9 A T16 A approx. 40 W 11.0 kg Dimension sheet Connection diagram Ziehl-Abegg AG Heinz-Ziehl-Straße D-74653 Künzelsau Tel.: +49 (0) 7940 16-0 Fax: +49 (0) 7940 16-504 info@ziehl-abegg.de http://www.ziehl-abegg.de RAE-9G 1 2 3 4 5 6 7 65V… 230V AC L SR146K03 23.05.2006 2* N L1 PE N L1 1~ Motor ohne Thermokontakte without thermocontacts sans thermocontacts utan termokontakter M 1~ PE U1 U2 U1 U2 Netz / line / secteur Nätanslutning 1~ 230V 50/60Hz Kontaktbelastung contact rating pouvoir de coupure kontaktbelastning 230VAC max. 1A Sicherungen sind nicht im Steuergerät enthalten. Diese müssen bauseits angebracht werden. Fuses are not included in the controller. These have to fix construction side. Les fusibles ne sont inclus dans le contrôleur. Ceux-ci doivent étre installés le client. Säkringar ingår ej i transformatorn, dessa måste placeras dit. 2* 2* 2* 2* 2* > 1 2 3 4 5 6 5-Stufenthermostat 5 step thermostat thermostat 5 niveaux 5-stegs termostat SRE5
Open the catalog to page 1All ZIEHL-ABEGG catalogs and technical brochures
-
Fans for transformer cooling
260 Pages
-
Fans for railroad engineering
334 Pages
-
Fans for heat pumps
4 Pages
-
ECblue high-efficency motors
14 Pages
-
FE2owlet
4 Pages
-
Axial fans main catalogue_2016
544 Pages
-
ZAwheel
12 Pages
-
ZAdyn 4c
4 Pages
-
EVAC 3
8 Pages
-
MAXvent owlet
10 Pages
-
Product range
4 Pages
-
Axial Fans Main Catalogue FE2owlet
144 Pages
-
Flyer Fans for wind turbines
5 Pages
-
Flyer Cpro ZAmid
4 Pages
-
ECblue brochure
20 Pages
-
Drive technology
112 Pages
-
COMPLETE PROGRAMME
24 Pages
Archived catalogs
-
FE2owlet-50Hz - part 2 - FN040
11 Pages
-
DL2.5 Controllers
38 Pages
-
FC100, FC125
38 Pages
-
A01 60 Hz North America FB-Series
24 Pages
-
A01 60 Hz North America FE-Series
30 Pages
-
R-DK...KT(G)
2 Pages
-
R-D-1...7
1 Pages
-
RAE-2/4/7G
1 Pages
-
R-E1.5...14G
1 Pages