EVAC 3
8Pages

{{requestButtons}}

Catalog excerpts

EVAC 3 - 1

The Royal League of fans, control technology and drive technology EVAC 3 Evacuation units for elevators

Open the catalog to page 1
EVAC 3 - 2

The simplest evacuation during a power failure The EVAC 3 series units are evacuation modules specifically designed for elevator technology. The compact construction and sophisticated design make the modules perfect for both control cabinet installation (EVAC 3B) and wall installation (EVAC 3C). Functional description The EVAC 3 evacuation unit monitors the power supply of the ZETADYN 3 frequency inverter. With the drop out of one or more phases the ZETADYN 3 will be disconnected from the mains power supply. At the same time, the elevator control is informed about the mains failure. The...

Open the catalog to page 2
EVAC 3 - 3

EVAC 3B The solution for control cabinet installation The compact design of the EVAC 3B facilitates easy installation in a control cabinet. In combination with the ZETADYN 3BF, the perfect solution. Individual features • LED display for operation / malfunction • 4 x relay outputs • 2 x digital inputs (24 VDC) • Battery voltage 96 VDC ... 216 VDC Additionally required components • Battery set matching the required power • Uninterruptible power supply (UPS) 230 VAC to supply: • Elevator control • Cabin light • EVAC 3B • Door drive • Motor brake • Power contactors to switch from normal to...

Open the catalog to page 3
EVAC 3 - 4

The special design and integrated components facilitates simple and quick installation of the EVAC 3C on the wall in the machine room or in the elevator shaft. The external main switch provides problem-free use with machine room less elevators. In combination with the ZETADYN 3C, the perfect solution. Individual features • ED display for operation / malfunction L • x relay outputs 4 • x digital inputs (24 VDC) 4 • attery voltage 96 VDC ... 216 VDC B • xternal main switch; that enables installation in the eleE vator shaft • refabricated cables for quick installation P • ntegrated power...

Open the catalog to page 4
EVAC 3 - 5

Technical data EVAC 3 Type designation Power consumption, charging [W] Lead-acid rechargeable battery Lead-acid rechargeable battery Lead-acid rechargeable battery Lead-acid rechargeable battery Time limit, evacuation mode [min] Mains connection voltage [VAC] Nominal current [A] Battery type

Open the catalog to page 5
EVAC 3 - 6

Battery set Both evacuation units require a battery set for the power supply of the frequency inverter and additional components. The required voltage and capacity of the battery set is determined by the technical data of the motor and the duration or number of evacuation trips. Technical data battery set Type designation Dimensions WxHxD [mm] Weight [kg] Technical data battery set Type designation Dimensions WxHxD [mm] Weight [kg] Battery set (only EVAC 3C) Prefabricated cables are available for fast and simple connection of the EVAC 3C: (1) (2) (3) (4) (5) (6) EVAC EVAC EVAC EVAC EVAC...

Open the catalog to page 6
EVAC 3 - 7

More competence. Mehr experience. More commitment. Along with the excellent, easy to operate products, personal customer support and rapid, punctual delivery, customer focused service is one of our great strengths. Competent support by expert and experienced service technicians are the prerequisite for saving money and time onsite. With just such a comprehensive service package, we make a significant contribution to quickly commissioning your elevator installation. • TÜV-safe drive-system engineering designs • Application-engineering advice to help select the in verters, machines,...

Open the catalog to page 7
EVAC 3 - 8

© Ziehl-Abegg - 00000000-GB - 04/2011 - mag - 1´ - K&E - Subject to technical modifications Ziehl - A begg AG Heinz-Ziehl - Straße info@ ziehl - abegg.c om

Open the catalog to page 8

All ZIEHL-ABEGG catalogs and technical brochures

  1. FE2owlet

    4 Pages

  2. ZAwheel

    12 Pages

  3. ZAdyn 4c

    4 Pages

  4. MAXvent owlet

    10 Pages

Archived catalogs

  1. FC100, FC125

    38 Pages

  2. R-DK...KT(G)

    2 Pages

  3. R-D-1...7

    1 Pages

  4. RASE9G

    1 Pages

  5. RAE-2/4/7G

    1 Pages