|
|
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | AC Power Sources, AC Filte | | | | | | | | | | | | | | | | | | | | | | Series | Type | Ph. | Power kVA | Frequency | UA | Application | | | | i | 5001i | 1 | 5 | DC, 16Hz-5kHz | 0-270V | Usable for SYS61K | | | | 15001Í | 15 | | | | 15003i | 3 | 15 | | | | 30003i | 30 | | | | RP | 801RP | 1 | 0.8 | 16Hz-500Hz | Usable with restrictions for SYS61K | | | | 1251RP | 1.2 | | | | 2001RP | 2.0 | | | | 2003RP | 3 | 2.0 | | | | P | 801P | 1 | 0.8 | General applications 1 | | | | | | | | | | 1251P | | 1.2 | | | | | | | AC-Filter | TT-AC1000 | 1 | 1 | Mains freq. | Mains | Cost-effective_1 | | | | | | | | | | | | | | | | | | | | | | Test Systems for EN61000-3-2/-3 (Current Harmonics, Flicker) | | | | | | | | | | | | | | | | | | | | | | | | | | | | Instrument Type | Power Channels | Frequency Range (Bandwidth) | Basic Accuracy | Ranges Voltage, Current | Harmonic Analysis | Computer Interfaces | Process Signal Interfaces | Display | Mech. Design 1 | Dimensions W x H x D in mm | Application | Special Features | | | | SYS61K -3PL50 | 3 Ch. | DC-10MHz | 0.03% | 3V-1000V 20mA-32A | EN 61000-3-2 | RS232, IEEE488.2 USB | Inputs: 4 Analog 4 Digital | Colour-TFT 320x240 | to be built-in into e.g. | 6...18HU x 800mm | For EMC test systems meeting standard EN61000-3-2/-3, | Packages to build complete systems, consisting of: 1 to 3 power meters LMG95 or one LMG500, AC power sources, reference impedance and evaluation software | | | | | | | | | | | 1Frequency Outputs: 4 Analog 4 Digital | | 19"-racks | | harmonics analyser meets EN61000-4-7, flicker meter meets EN61000-4-15 | (components also available for stand-alone operation, simple integration of existing customer sources) | | | | SYS61K -1(3)PL95 | 1 (3) Ch. | DC, 0.05Hz-50kHz | | 6V-600V 0.15A-20A (960Apk) | | RS232, IEEE488.2 | LCD b/w 240x128 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Energy Counters and Displays to monitor and maintain Production an | | Factory | | | | | | | | | | | | | | | | | | | | | | | | | | | | RM303d8 | 1-3 | 45-65Hz (1kHz) | Power: Class 0.25 Energy: Cl.1 (EN61036) | 230VLN / 400VLL optional: 63VLN / 110VLL dynamic range: 0.5...1.2UN 5A optional: 1A dynamic range: 0.005...1.2IN | | | 1 pulse relais + optional 1 pulse relais | LCD, 1 row with 8 digits + unit, backlight | Rail mounting | 106 x 90 x 58 | Energy counter as general operation display, for control tasks and energy management | kW-display short term on push-button 1 | | | | PM303d8 | Panel mounting | 96 x 96 x80 | | | | | PM325 | 45-65Hz (2.5kHz) | Optional Modbus RS485 (RS422) | 1 pulse relais, + 1 pulse relais optional | LCD, 2 x 4,5 digits (kW), 7 dig.(kWh), backlight | Panel mounting | 96 x 96 x 80 | kW-display, average power kWMD and maximum average power kWMDmax | | | | RM350 | 45-65Hz (1kHz) | Optional Modbus RS485 | 2 pulse optocoupler | LCD, 1 x 8 digits + unit, backlight | Rail mounting | 106 x 90 x 58 | | | | | PM400 | 45400Hz | LCD, 4 x 4 digits + unit | Panel mounting | 96 x 96 x 83,5 | Optional with internet connection (PM400IP) | | | | PM380 | 45-65Hz (1kHz) | U,I: 0.2% FS P: 0.6% FS Energy: Cl.1 | Optional RS485 (RS422) | 2 pulse relais, options modul for 4 analog | LCD, 3 x 4 digits + unit, backlight | 96 x 96 x 80 | Phase values of: current, voltage, power factor, active-, reactive-, apparent-power. Total values of: active-, reactive-, apparent-power, average power, maximum average power, active-, reactive-, apparent-energy. Decentral registration and displaying of power and energy, also separately for import and export. Cost-effective replacement of many single displaying devices in panel mounting. | Cost-effective device, neutral current, average values: IMD, UMD maximum values of IMD, UMD | | | | PM396 | Power: 0.1% | 230VLN / 400VLL 5A (opt. 1A) | 1...15 (THD) | RS485 RS232 (opt. Profibus) | 2 digital 2 analog | LCD, 4 x 3 digits + unit | Panel mounting (opt. rail adapter) | 96 x 96 x 55 | Evaluation software in standard equipment, harmonic analysis | | | | TM396 | as above + 25A-option for I-Input | Desktop case | 248 x138 x 253 | Optional design with CEE-plug and -socket for simple measuring of loads with CEE-connectors | | | | EZI1 | 1 | 47-63Hz | P: 0.1% FS (0.25-25A) 0.5% FS (0.02-0.25A) | Range: 86V...250V, 0.02A...25A | | | 1 pulse 1 analog | No display | Wall set | 160x240 x 150 | Accurate energy measurement esp. of devices with great and frequent load fluctuation, e.g. refrigerators | Wide measuring range (0.02-25A, 86-250V) with high accuracy in the hole dynamic range, high resolution (25 pulses/Wh) | | | | PM190 PM151 PM96 | | DC | 0,1% ± 1 digit | 0-10V 0/4-20mA | | | 4 relais 4 opto coupler | VF-display 3 digits + sign 51/101 segm. bar | Panel (190/96), 19" (151) | 144x48 96x48 3HU/1PU | Displaying and monitoring of processes | Bargraph for simultaneous analogue indication of measuring- and limit values. Standard process inputs | | | | | | | | | | | | | | | | | | | | | | | | | | | | Subject to technical changes, especially to improve the product, at any time without prior notification. | | | | | | | | | | ZES ZIMMER Electronic Systems GmbH Tabaksmühlenweg 30, D-61440 Oberursel/Germany Tel. +49 6171 628750 Fax +49 6171 52086 www.zes.com • sales@zes.com | | | | | | jZ^S ZIMMER! ¡Electronic Systems! | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|