| | | Technical data | | |
| | | |
| | | | | | | | | | | | | | | | | Type | Capacity*) | | Dimensions | | Connection | Pressure | Weight | electr. Connection | | | | | m3/h | A | mm B | C | mm | bar | kg | Watt | | | | K-MT 1 | 8 | 312 | 390 | 210 | G 1/4 | 16 | | 50 | | | | K-MT 2 | 15 | 312 | 565 | 210 | G 1/4 | 16 | 13 | 50 | | | | K-MT 3 | 25 | 359 | 815 | 210 | G 1/4 | 16 | 17 | 50 | | | | K-MT 4 | 35 | 359 | 1065 | 210 | G 1/4 | 16 | 24 | 50 | | | | K-MT 6 | 56 | 436 | 1185 | 300 | G 3/8 | 16 | 52 | 50 | | | | K-MT 7 | 72 | 436 | 1410 | 300 | G 3/8 | 16 | 65 | 50 | | | | K-MT 8 | 86 | 436 | 1610 | 300 | G 1/2 | 16 | 77 | 50 | | | | | | | | | | | | | | | | |
| | | |
| | | * calculated at 1 bar (abs) and 20°C | | |
| | | |
| | | | | | | | | | | | | | | | | Type | Capacity*) | | Dimensions | | Connection | Pressure | Weight | electr. Connection | | | | | m3/h | A | mm B | C | mm | bar | kg | Watt | | | | KA-MT 1 | 8 | 445 | 390 | 210 | G 1/4 | 16 | 12 | 50 | | | | KA-MT 2 | 15 | 445 | 565 | 210 | G 1/4 | 16 | 17 | 50 | | | | KA-MT 3 | 25 | 492 | 815 | 210 | G 1/4 | 16 | 24 | 50 | | | | KA-MT 4 | 35 | 492 | 1065 | 210 | G 1/4 | 16 | 34 | 50 | | | | KA-MT 6 | 56 | 629 | 1185 | 300 | G 3/8 | 16 | 72 | 50 | | | | KA-MT 7 | 72 | 629 | 1410 | 300 | G 3/8 | 16 | 90 | 50 | | | | KA-MT 8 | 86 | 629 | 1610 | 300 | G 1/2 | 16 | 107 | 50 | | | | | | | | | | | | | | | | |
| | | |
| | | * calculated at 1 bar (abs) and 20°C | | |
| | | |
| | | Conversion factor pressure / Conversion factor temperature temperature °C pressure bar(e) | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | 5 6 7 8 9 10 | 11 | 12 | 13 | 14 | 15 | 16 | | | | 35 | 0.75 | 0.89 | 1.00 | 1.08 | 1.26 | 1.31 | 1.36 | 1.49 | 1.62 | 1.71 | 1.79 | 1.90 | | | | 40 | 0.64 | 0.78 | 0.91 | 1.00 | 1.08 | 1.16 | 1.24 | 1.36 | 1.47 | 1.57 | 1.67 | 1.77 | | | | 45 | 0.61 | 0.73 | 0.82 | 0.94 | 1.03 | 1.07 | 1.10 | 1.23 | 1.35 | 1.46 | 1.57 | 1.66 | | | | 50 | 0.59 | 0.67 | 0.79 | 0.86 | 0.99 | 1.03 | 1.07 | 1.18 | 1.29 | 1.38 | 1.46 | 1.55 | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | Operating pressure <5 bar on request alternatively use heat regenerated dryers. High inlet temperature on request. | | |
| | | |
| | | K-MT | | KA-MT | | |
| | | |
| | | Design example Compressed air to be dryed flow rate|HHIIIIl35 m3/h pressure^^^^^Hb bar(e) inlet temperature^^H35 °C press. dew point -40 °C | | |
| | | |
| | | 35 | | |
| | | 27.8 m3/h | | |
| | | Dryer capacity = Selected: K-MT 4 | | |
| | | |
| | | 1.26 | | |
| | | |
| | | |
| | | |
| | | We reserve the right to change design and dimensions | | |
| | | |
| | | ZANDER Aufbereitungstechnik GmbH Im Teelbruch 118, D-45219 Essen Postfach 18 55 24, D-45205 Essen Tel. (0 20 54) 9 34-0 • Telefax (0 20 54) 9 34-164 Internet: http://www.zander.de A Division of Parker Hannifin Corporation | | |
| | | ZANDER | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |