Maximum allowable concentrations for breathing air
Breathing air purification BS-MT multitronic series
Features and utilisation Breathing air for the industrial application *under inlet temperatures Oxygen concentration Oil components Pressure dew-point* Carbon dioxide Carbon monoxide Odour and flavour substances Adsorption Dryerbreathing star BS-MT multitronic O Öl<0,5mg/m CO CO<15ppm<5ppm<10ppm<10ppm<2ppm H 2 2 O<5°C<5°C<10°F<100mg/m 2 = <500ppm<500ppm<1000ppm<800ppmbis zu 150ppm 21(+/–1) EuropaUKUSAAusralienZANDEREN 12021BS4275ANSI/CGAAS 1715with BS-MT freefreefreefreefree %= 3 Compressed air for industri-al application provides
human beings reliably with
high quality conditioned
breathing air. This breathing
air is free from effects of
the working environment. ZANDER offers the marketfor the industrial breathing
air sector proven adsorption
technology, with a high
emphasis on savety in
regard to maximum allow-able impurity concentrations
depending on specific coun-
try regulations. Adsorption dryers of the BS-MT series are eminently
suitable as breathing air
conditioning units for indu-
strial applications by virtue
of exactly matched conditio-
ning steps <0,5mg/m 20-23 %= 3 <5,0mg/m 21,5 %= 3 -Pre filter -Adsorption phase A -After filter -Cleaning 2nd stage -Catalyst stage -Cleaning 1st stage -Adsorption phase B filters condensate up to
0,01 mg/m filters solid particles reduces CO eliminates oil components reduces CO adsorbs moisture converts CO to CO <1,0mg/m 3 2 2 fractions 3 3 <0,003mg/m <–40°C 2 20,8-21,1 % 3 • The ZANDER adsorption dryers ofthe BS-MT series for breathing air
are characterised by the following
features: be harmful to the human organism. Compressed air from the compres-sor contains impurities such as
solid particles, condensate, oil
components, odour and flavour
substances and other harmful
gases.The ZANDER breathing air purifica-tion unit Series BS-MT dependably
removes and reduces these com-ponents from the compressed air.
The ZANDER microfilters Series X
reliably remove the solid and liquidimpurities with 0.01 µm and 0.01
mg/m Service life Filter element 8.000 operating hours
Desiccant 4.000 operating hours•Pressure dew-pointup to –40°C•Flow rate up to 6.000 m 3 filtration efficiency. The compressed air saturated withmoisture is then fed into the dryer.
For the adsorption the air flows
through the adsorption chamber
from the bottom to the top. A spe-
cial desiccant mixture retains the
moisture and reduces the fraction
of the various gases which could 3 /h•Pressure ratings up to 350 bar•Exceed international guidelines •Lower operating costs•Variable control•Compressor control
Suitable for operation and utilisati-on in the sectors off: • Dry clean compressed air leaves
the adsorption dryer.
Parallel to the adsorption, regene-
ration takes place in the second
adsorption chamber. A partial flow
of decompressed dried regenera-
ting air flows through the adsorber
which is to be regenerated in coun-
terflow, removes the moisture
picked up by the desiccant and
then escapes into the open atmos-
phere via the downstream muffler. The continual pressure change inoperation requires a pressure
build-up during the cycles and gua-
rantees pulsation free switchover
from regeneration to adsorption.
The activated carbon catalyst char-
ge of the downstream cleaning
stage removes odour and flavour
substances, oil vapours, various
gas fractions and carbon monoxi-
de. The universal filter retains any
particles of the adsorbers. Hospitals•Surface treatment technology and paintshops•Pharmaceutical industry•Fire brigades•Disaster control •Laboratories•Chemical and petrochemical industry•Tank cleaning and shaft con-struction•Tunnel construction•Mines•Shipyardes•Diving industry
|
|