L1000/110 Belt Conveyor - ZANAM-LEGMET Spolka z o.o. - #3

/ 3


catalogue search
P. 01
P. 02
P. 03
Pages:


See other catalogues for ZANAM-LEGMET Spolka z o.o.

Text version of the page

L10 00 /11 Main Technical Parameters

Basic information

Belt width ‘B’ 10 00
o mm
o Belt trough angle ‘ β ’ 33 – 35 Belt speed ‘v’ 2,0 m/s 2,5 m/s

Belt ten sioning

Power of a driving station ‘N’ 2x11 0 kW Height of tensioning pylons 6370 mm 10270 mm Tensioning rope transmission ratio ‘i
p ’ 2 or 3

Conveyor capacity ( γ =1,7 Mg/m

3

;

Drum diameter φ 355 mm

kz=0,8)

Rope diameter φ 16 mm at v=2,0 m/s 535 Mg/h at v=2,5 m/s 646 Mg/h

Conveyor route

Spacing between conveyor supports down the route

Driving unit

2500 mm Electric motor Typ Sg Spacing between upper roller sets 1250 mm Electric motor power 110 kW Spacing between lower roller sets 2500 mm Synchronous rotation speed 1485 rpm Upper roller diameter 133 mm Pulley drum diameter φ 630 mm Lower roller diameter 108 mm
o +15 – po Passive drum diameter φ 630 mm Maximum allowed angles for conveyor routes inclined
o Gearbox transmission ratio 20 - 10 – po ‘i’ 25 declined Coupling type Hydrokinetic wysokoelastyczne

Self - response extinguishing unit SUG - 3 The self - response extinguishing unit SUG - 3 is dedicated for spontaneous extinguishing of fires that can break out down routes of belt conveyors. They are tripped when any of the sensors installed down the conveyor route detects exceeding of the temperature threshol d..

TECHNICAL SPECIFICATION Legnica

2008

pageCatalog pdf di En 2012-06-22-01