General Specications Model ZR22G, ZR402G, and ZR202G Direct In Situ Zirconia Oxygen Analyzers and High Temperature Humidity Analyzers Overview This analyzer consists basically of a probe and a converter that are used as both a Zirconia Oxygen Analyzer and High Temperature Humidity Analyzer. The probe is of direct insertion type, and the converter uses a digital display. Two types of analyzers are available: separate type and integrated type. As its name implies, the integrated type combines probe and converter. Separate and integrated type Zirconia oxygen analyzers need not use a sampling device, and allow direct installation of the probe in the wall of a ue or furnace to measure the concentration of oxygen in the stack gas. The converter displays the cell temperature and cell emf in addition to the oxygen concentration. This analyzer is most suitable for monitoring the oxygen concentration of combustion gases in large or small boilers, various industrial furnace and combustion devices, or for the control of low-oxygen combustion. Separate type and integrated type Zirconia High Temperature Humidity Analyzers are used to measure the humidity of hot gases continuously in driers which use an electrical heater or hot gas as the heat source. They can also be used in a variety of manufacturing applications in humidiers, as well as in driers, for humidity measurement and control. They can help improve productivity in these application elds. Features: • The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs. • The probe uses a long-life, high-reliability Zirconia sensor. • The probe uses three-reference gas supply methods (natural air convection, instrument air, and pressure compensated) in its applications. • The separate type converter incorporates a LCD touchscreen for ease of operation. • This converter can be used as an oxygen analyzer as well as a high temperature humidity analyzer. • The integrated type integrates both probe and converter, to reduce wiring, piping, and installation costs. This type of unit uses an optical switch for ease of operation at the site. • Remote maintenance using digital communications (HART) reduces maintenance costs. *1 *1: HART is a registered trademark of HART Communication Foundation 4 to 20 mA DC signal line with superimposed HART AC signal Relaying terminals Ao+ + Control room Terminal board Receiving instrumen load resistance: 250 Ω to 550 Ω HART Communicator Model 275 HART Communicator Model 275 HART Communicator Model 275 Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5617 Fax.: 81-422-52-6792 GS 11M12A01-01E ©Copyright June 2000 12th Edition Dec. 2012
Open the catalog to page 1Basic System Conguration System conguration - Separate type System configuration Example 1 of Separate type Analyzer Automatic calibration system uses instrument air for reference gas. For the calibration gas, a standard gas cylinder may be used for more accurate calibration. Applications: Oxygen concentration monitoring and control in large boilers (for private power generation and for business use) and in heating furnaces, and the like. Humidity monitoring and control in drying furnaces and humidifiers. ZR22G Separate type Zirconia Oxygen/High Temperature Humidity Analyzer, Detector *2 *1...
Open the catalog to page 2Basic System Conguration System conguration — Separate type System configuration Example 2 of Integrated type Analyzer System configuration Example 2 of Separate type Analyzer Instrument air is used as the reference gas. A standard gas cylinder can be used for the calibration gas for more accurate calibration. Application example: Oxygen concentration monitoring and control in large boilers (for private power generation and for business use) and in heating furnaces. Humidity monitoring and control in drying furnaces and humidifiers. ZR22G Separate type Zirconia Oxygen/High Temperature...
Open the catalog to page 3System Components Separate type Integrated type Model ZR22G Separate type Zirconia Oxygen / High Temperature Humidity Analyzers,Detector Model ZR402G Separate type Zirconia Oxygen / High Temperature Humidity Analyzer, Converter(*1) Model ZR202G Integrated type Zirconia Oxygen / High Temperature Humidity Analyzers Model ZO21P High Temperature Probe Adapter for separate type Zirconia Oxygen Analyzer E7046EC, E7046EN Auxiliary Ejector Assembly for High Temperature Probe of separate type Oxygen Analyzer Model ZO21R Probe Protector for Zirconia Oxygen Analyzers K9471UA Dust Filter for Oxygen...
Open the catalog to page 4■STANDARD SPECIFICATIONS (Oxygen Analyzer) Example of Application Separate and integrated type Zirconia Oxygen Analyzers • Large, medium and small boilers (boilers for power generation: heavy oil, gas or coal) • Various industrial furnaces (renery process/iron manufacture heating furnace, coal kiln, and black liquid recovery boilers) For other applications, contact Yokogawa Electric Corporation. • May not be applicable corrosive gas such as ammonia, chlorine is present-check wit YOKOGAWA. General Specications Oxygen Analyzer Measurement Object: Oxygen concentration in combustion exhaust gas...
Open the catalog to page 5<> <> When the probe insertion length is 2.5 m or more, mount vertically downward (within ±5°) and use a probe protector. Weight: Insertion length of 0.4 m: approx. 6 kg (JIS 5K 65) / approx. 11 kg (ANSI 150 4) Insertion length of 1.0 m: approx. 8 kg (JIS 5K 65) / approx. 13 kg (ANSI 150 4) Insertion length of 1.5 m: approx. 10 kg (JIS 5K 65) / approx. 15 kg (ANSI 150 4) Insertion length of 2.0 m: approx. 12 kg (JIS 5K 65) / approx. 17 kg (ANSI 150 4) Insertion length of 3.0 m: approx. 15 kg (JIS 5K 65) / approx. 20 kg (ANSI 150 4) Insertion length of 3.6 m: approx. 17 kg (JIS 5K 65) /...
Open the catalog to page 6<> <> Password Functions: Enter your password to operate the analyzer excepting data display. Individual passwords can be set for maintenance and setup. Display and setting content: Measuring Related Items: Oxygen concentration (vol% O2), output current value (mA), air ratio, moisture quantity (in hot gases) (vol% H2O) Display Items: Cell temperature (°C), thermocouple reference junction temperature (°C), maximum/minimum/average oxygen concentration (vol% O2), cell e.m.f. (mV), cell internal resistance (Ω), cell condition (in four grades), heater on-time rate (%), calibration record (ten...
Open the catalog to page 7All YOKOGAWA Europe catalogs and technical brochures
-
YS1500
20 Pages
-
UM33A/S006
2 Pages
-
YTA610
20 Pages
-
FA-M3V
19 Pages
-
RAMC
24 Pages
-
GS610 Source Measure Unit
12 Pages
-
EJXC40A Digital Remote Sensor
135 Pages
-
TB750G EXAxt
3 Pages
-
VPSRemote Remote Solution
2 Pages
-
SENCOM Degital Sensor
3 Pages
-
Product Solution Catalog
8 Pages
-
Data Logging Software GA10
4 Pages
-
JUXTA VJ series
7 Pages
-
µR10000/µR20000
8 Pages
-
OX400
2 Pages
-
PR300 Power and Energy Meter
4 Pages
-
CENTUM RIO System Upgrade
4 Pages
-
Autonomous Controller FCN-RTU
17 Pages
-
MW100
5 Pages
-
FieldMate
5 Pages
-
AMADAS
4 Pages
-
Exapilot
5 Pages
-
Exaquantum
5 Pages
-
BUCA150_E_050
4 Pages
-
BUAQ7280-01
12 Pages
-
BUXL120_E_030
8 Pages
-
BU7603_00E_060
20 Pages
-
BUAQ2200
8 Pages
-
NR800 Near Infrared Analyzer
8 Pages
-
GD402 Gas Density Analyzer
3 Pages
-
DT450G Dust Monitor
3 Pages
-
SCADA Software VDS
7 Pages
-
Batch Control
9 Pages
-
FieldMate catalogs
5 Pages
-
DPharp for The Digital World
9 Pages
-
RAGN Rotameter
2 Pages
-
HART Communicator YHC5150X
2 Pages
-
Catalog_YMI130_EN
86 Pages
-
Bulletin11G04G01-01E
3 Pages
-
Bulletin11B03A03-01E
10 Pages
-
FY01A08A08-E-E
2 Pages
-
Ultrasonic Flowmeter US300FM
2 Pages
-
AXF Verification Tool
2 Pages
-
ADMAG Series
9 Pages
-
Exaplog
2 Pages
-
AAASuite
2 Pages
-
InfoWell
8 Pages
-
Low Power Controller FCN-RTU
3 Pages
-
Standalone SIS
3 Pages
-
VTSPortal
2 Pages
-
CENTUM VP - CAMS for HIS
4 Pages
-
GS01E06K02-00E
2 Pages
-
U33Q01A01-01E
11 Pages
-
BU33K01A01-50E
11 Pages
-
Thermometers Catalog
8 Pages
-
PH400G 4-Wire Type pH Meter
27 Pages
-
SG750 Stack Gas Analyzers
26 Pages
-
Clamp-on Testers
12 Pages
-
Dust Monitor DT450G
3 Pages
-
Handy Calibrators
4 Pages
-
CENTUM.VP
11 Pages
-
Fieldbus Segment Indicator
5 Pages
-
ADMAG AXF
2 Pages
-
YTA series
7 Pages
-
TEST & mEASUREmENT 2011
28 Pages
-
digital multimeter series
12 Pages
-
WT 3000 Precision Power Analyzer
19 Pages
-
DL850/DL850V SCOPECORDER
14 Pages