GC1000 Mark II Process Gas Chromatographs  
20Pages

{{requestButtons}}

Catalog excerpts

GC1000 Mark II Process Gas Chromatographs   - 1

General Specifications Model GC1000 Mark II Process Gas Chromatograph A Gas Chromatograph analyzes a gas or volatile liquid sample by separating components for detection. The discrete separation and positive identification of components and measurement of the composition with no interference is a positive advantage of the gas chromatograph. Making good use of this advantage, the process gas chromatograph is widely used in many industries. YOKOGAWA manufactures two models of GC1000 Process Gas Chromatographs: the GC1000E/C/ S (isothermal oven type) and the GC1000T/W/D (programmed temperature type). The GC1000E/ C/S can analyze gas and liquid samples from room temperature up to elevated temperatures corresponding to their boiling points. The GC1000T/ W/D is capable of performing high resolution analysis by using capillary columns similar to laboratory gas chromatograph. n Capabilities of analyzing PIONA and the Distillation points Techniques for laboratory analyses can also be utilized in the GC1000 series by configuring and installation of high resolution capillary columns. This allows for the analysis of properties such as PIONA and Distillation points. n Capability of analyzing high boiling point liquid samples The liquid sampling valve with vaporizer having a tight seal provides highly accurate liquid sampling. The liquid sample is vaporized by an internal heater and introduced to the columns. This allows for highly consistent sample volume and excellent reproducibility. n Capability of analyzing samples in a very wide range of boiling points In the thermostatic oven, temperature is accurately controlled within +/- 0.03°C by an air-bath and circulation fan. For wide boiling point range samples, the programmed temperature oven enables the GC1000 to analyze these samples with high resolution. n Easy operation via User Friendly Displays User friendly keyboard and display allows easy operation and display of analysis data. Many functions can easily be accessed to the user including auto gate tracking, column end-of-life warning and auto gain setting. n Enhanced maintenance using PC operation With our maintenance terminal software (GCMT/ ASMT), the GC1000 can be operated from remote location like the control room or office. In addition, the analyzer bus allows for total maintenance management system to include other field analyzers and data acquisition capabilities. n Achievement of High Sensitivity TCD Most analysis which normally requires FID detector can now be done using the new high sensitivity TCD detector. This eliminates the requirement of fuel gas and presence of flame as in the FID. n Expectation of the effective result by EPC EPC (Electronic Pressure Control) controls the utility gas pressure by electronics and software, providing the same efficiency as programmed temperature analysis. Examples of Applications in Industries The GC1000 can be used for monitoring and quality control in following industries and applications. l Petrochemistry: Ethylene, Poly-propylene, Polyethylene, BTX, Butadiene, Vinyl chloride, Styrene, Alcohol, Aldehyde, Ester, and Vinyl acetate l Petroleum refinery: Distillation point analysis, PNA/ PINA analysis, FCC, Sulfur Recovery l Chemistry: Silicone, Chlorides, Fluorine compounds, Formalin, methanol, Urea, Ammonia, Phenol l Electric power/gas: Fuel gas, Exhaust gases, Coal gasification/liquefaction, Fuel cell l Iron and steel: Blast furnace, Coke oven l Air plant: Inorganic gas analyses l Chemicals: Chemicals, Agricultural Chemicals l Environmental monitoring: Air pollution observation, Plant/Work environmental analyses The GC1000 can, of course, respond to many other applications. Yokogawa Electric Corporation 2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Tel.: 81-422-52-5617 Fax.: 81-422-52-6792

Open the catalog to page 1
GC1000 Mark II Process Gas Chromatographs   - 2

n WIRING AND PIPING DIAGRAM (1) Using Vent Stack (Note 9) Independent grounding (100Ω or less) (Note 8) Communlcation via personal computer Transmission: Analysis results, Operation info., Operational conditions Reception: Operation requests, Operational conditions change RS-422, 19.2/38.4k bps; for explosion protection, an RS-422/RS-232C converter is provided. Communication via DCS Transmission : Analysis results Reception : Operation requests RS-422 1200/2400/4800/ 9600/19200bps for explosion protection, an RS-422/RS-232C converter is provided. Analog input (4 to 20mA DC/1 to 5V DC) 4...

Open the catalog to page 2
GC1000 Mark II Process Gas Chromatographs   - 3

Using No Vent Stack (Note 7) Independent grounding (100Ω or less) (Note 6) Communlcation via personal computer Transmission: Analysis results, Operation info., Operational conditions Reception: Operation requests, Operational conditions change RS-422, 19.2/38.4k bps; for explosion protection, an RS-422/RS-232C converter is provided. Communication via DCS Transmission : Analysis results Reception (Note 4) : Operation requests RS-422 1200/2400/4800/ 9600/19200bps for explosion protection, an RS-422/RS-232C converter is provided. Analog input (4 to 20mA DC/1 to 5V DC) 4 points Contact input...

Open the catalog to page 3
GC1000 Mark II Process Gas Chromatographs   - 4

Measurable object: Gas or liquid Measurement principle: Component separation·····by elution Detection··························TCD, FID, FPD Measurable ranges: TCD················1ppm to 100% · FID··················1ppm to 100% FPD· ···············1ppm to 0.1% · Number of streams to be measured: Maximum of 31 (including standard sample) Number of components to be measured: Maximum of 255 Analysis period: aximum of 99999.9 sec. M Quantifying method: Absolute calibration Sensitivity-corrected absolute calibration Corrected area normalization Material of the sample-contact parts: Stainless...

Open the catalog to page 4

All YOKOGAWA Europe catalogs and technical brochures

  1. YS1500

    20 Pages

  2. UM33A/S006

    2 Pages

  3. YTA610

    20 Pages

  4. FA-M3V

    19 Pages

  5. RAMC

    24 Pages

  6. TB750G EXAxt

    3 Pages

  7. OX400

    2 Pages

  8. MW100

    5 Pages

  9. FieldMate

    5 Pages

  10. AMADAS

    4 Pages

  11. Exapilot

    5 Pages

  12. Exaquantum

    5 Pages

  13. BUAQ7280-01

    12 Pages

  14. BU7603_00E_060

    20 Pages

  15. BUAQ2200

    8 Pages

  16. ADMAG Series

    9 Pages

  17. Exaplog

    2 Pages

  18. AAASuite

    2 Pages

  19. InfoWell

    8 Pages

  20. VTSPortal

    2 Pages

  21. U33Q01A01-01E

    11 Pages

  22. BU33K01A01-50E

    11 Pages

  23. CENTUM.VP

    11 Pages

  24. ADMAG AXF

    2 Pages

  25. YTA series

    7 Pages