Group: Yokogawa
Catalog excerpts
Differential Pressure Level Solutions Bulletin 01C25A04-01EN-Y
Open the catalog to page 1Differential Pressure Level Solutions Liquid tank level is one of the basic measurements used in process plants but, its importance cannot be overstated. Incorrect high levels can cause the vessel to overflow leading to lost product, a safety hazard, or an environmental problem (or all three). Incorrect low levels can burn out pumps. Incorrect level measurement can cause problems with inventory control. There are many different technologies available, but, the most widely employed is differential pressure. Yokogawa differential pressure level solution uses an easy to understand principle,...
Open the catalog to page 2Benefits of DPharp Sensor Yokogawa's DPharp digital Pressure transmitters set a new standard for high performance, safety and robustness. • High Accuracy • Long Term Stability • Safety as Standard • Multi-sensing • Fast Response Models Yokogawa liquid level transmitters are available with two different performance tiers and three types of process connections. The EJA-E series is Yokogawa's primary product line. An evolution of Yokogawa's original DPharp transmitters, this series provides the performance and ruggedness that is expected from Yokogawa. The EJX series is Yokogawa's premier...
Open the catalog to page 3Typical Applications Level Measurements with Tank Blanketing Density Measurement Incorrect level measurement can cause the tank to overflow leading to lost product, safety hazards, environmental problem, or burn-out pumps, or errors in inventory control. Changes in temperature or variations in composition of the liquid being measured in the tank can cause a change in density. Since density is a critical part of the level measurement, we need to able to measure it. By mounting a pressure transmitter on two fixed position taps on the tank, the density can be calculated. Both tabs would need...
Open the catalog to page 4Challenges and Solutions Ambient Temperature Effects Temperature can have a major impact on the accuracy of pressure transmitters, especially those using diaphragm seals attached via capillaries. As temperature changes, fill fluid in the capillaries change density. This density change causes a Zero Shift leading to an inaccurate level measurement. This effect gets worse as the length of the capillary increases. Yokogawa’s DPharp transmitters have three different solutions, fill fluid density compensation, compensating capillaries, and digital remote sensors to overcome this problem. Fill...
Open the catalog to page 5Digital Remote Sensors Digital Remote Sensor (DRS) Traditional differential pressure measurements using capillaries have reduced performance when the capillaries are longer. There comes a point when the performance of the traditional system is no longer good enough for the measured parameter to be useful. Yokogawa’s DRS can solve this problem. DRS uses two individual pressure sensors; one placed on the high-pressure tap and the second placed on the lowpressure tap. The two sensors communicate via a dedicated communication cable. The system uses the information from the two sensors to derive...
Open the catalog to page 6http://www.yokogawa.com Printed in Japan, 711(KP) [Ed : 02/b] YOKOGAWA ELECTRIC CORPORATION World Headquarters 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 180-8750, Japan http://www.yokogawa.com/ YOKOGAWA CORPORATION OF AMERICA 12530 West Airport Blvd, Sugar Land, Texas 77478, USA http://www.yokogawa.com/us/ YOKOGAWA EUROPE B.V. Euroweg 2, 3825 HD Amersfoort, The Netherlands http://www.yokogawa.com/eu/ YOKOGAWA ENGINEERING ASIA PTE. LTD. 5 Bedok South Road, Singapore 469270, Singapore http://www.yokogawa.com/sg/ YOKOGAWA CHINA CO., LTD. 3F TowerD Cartelo Crocodile Building, No.568 West...
Open the catalog to page 7All YOKOGAWA Europe catalogs and technical brochures
-
YS1500
20 Pages
-
UM33A/S006
2 Pages
-
YTA610
20 Pages
-
FA-M3V
19 Pages
-
RAMC
24 Pages
-
GS610 Source Measure Unit
12 Pages
-
EJXC40A Digital Remote Sensor
135 Pages
-
TB750G EXAxt
3 Pages
-
VPSRemote Remote Solution
2 Pages
-
SENCOM Degital Sensor
3 Pages
-
Product Solution Catalog
8 Pages
-
Data Logging Software GA10
4 Pages
-
JUXTA VJ series
7 Pages
-
µR10000/µR20000
8 Pages
-
OX400
2 Pages
-
PR300 Power and Energy Meter
4 Pages
-
CENTUM RIO System Upgrade
4 Pages
-
Autonomous Controller FCN-RTU
17 Pages
-
MW100
5 Pages
-
FieldMate
5 Pages
-
AMADAS
4 Pages
-
Exapilot
5 Pages
-
Exaquantum
5 Pages
-
BUCA150_E_050
4 Pages
-
BUAQ7280-01
12 Pages
-
BUXL120_E_030
8 Pages
-
BU7603_00E_060
20 Pages
-
BUAQ2200
8 Pages
-
NR800 Near Infrared Analyzer
8 Pages
-
GD402 Gas Density Analyzer
3 Pages
-
DT450G Dust Monitor
3 Pages
-
SCADA Software VDS
7 Pages
-
Batch Control
9 Pages
-
FieldMate catalogs
5 Pages
-
DPharp for The Digital World
9 Pages
-
RAGN Rotameter
2 Pages
-
HART Communicator YHC5150X
2 Pages
-
Catalog_YMI130_EN
86 Pages
-
Bulletin11G04G01-01E
3 Pages
-
Bulletin11B03A03-01E
10 Pages
-
FY01A08A08-E-E
2 Pages
-
Ultrasonic Flowmeter US300FM
2 Pages
-
AXF Verification Tool
2 Pages
-
ADMAG Series
9 Pages
-
Exaplog
2 Pages
-
AAASuite
2 Pages
-
InfoWell
8 Pages
-
Low Power Controller FCN-RTU
3 Pages
-
Standalone SIS
3 Pages
-
VTSPortal
2 Pages
-
CENTUM VP - CAMS for HIS
4 Pages
-
GS01E06K02-00E
2 Pages
-
U33Q01A01-01E
11 Pages
-
BU33K01A01-50E
11 Pages
-
Thermometers Catalog
8 Pages
-
PH400G 4-Wire Type pH Meter
27 Pages
-
SG750 Stack Gas Analyzers
26 Pages
-
Clamp-on Testers
12 Pages
-
Dust Monitor DT450G
3 Pages
-
Handy Calibrators
4 Pages
-
CENTUM.VP
11 Pages
-
Fieldbus Segment Indicator
5 Pages
-
ADMAG AXF
2 Pages
-
YTA series
7 Pages
-
TEST & mEASUREmENT 2011
28 Pages
-
digital multimeter series
12 Pages
-
WT 3000 Precision Power Analyzer
19 Pages
-
DL850/DL850V SCOPECORDER
14 Pages