Clamp-on Testers
12Pages

{{requestButtons}}

Catalog excerpts

Clamp-on Testers - 1

Clamp-on Testers 300 Series and CL Series of Clamp-on Testers ^1 M li^r3 A^j^1 Leakage Clamp-on Tester with a sharp low pass filter function Leakage Clamp-on Tester capable of measuring from 1 mA AC Series Rich lineup for various current measurements Yokogawa Meters & Instruments Corporation

Open the catalog to page 1
Clamp-on Testers - 2

Selection Guide ■ For Leakage Current Model Diameter of measurable conductor Method of detection Frequency characteristics Range AC current Resolution AC voltage Other measurement DC voltage functions Continuity check Frequency Temperature Data hold Peak hold Recorder output Mean value display Filter Switch Waveform monitor output Page CL360 CL345 68mm 40mm Mean value True RMS 40Hz to 1kHz 20Hz to 1kHz 40/400mA,400A 200mA/2/20/200/1000A 0.1mA 0.01mA ● ● ● ● ● ● ● ● 9 8 *Page1: Description of Harmonic Filter Function ■ For AC Current Model Diameter of measurable conductor Method of detection...

Open the catalog to page 2
Clamp-on Testers - 3

Description of Harmonic Filter Function b Harmonic Filter Function (Only Available in the 30032A) 1. What is a Harmonic? Waveform Image Harmonic refers to sinusoidal quantity having a frequency that is an integral multiple of the fundamental frequency (for example, the commercial frequency). When a harmonic is superimposed on the fundamental frequency, the waveform is distorted. Fundamental frequency 2. Why is it Necessary to Accurately Measure the Leakage Current of the Fundamental Frequency (Commercial Frequency)? One problem when measuring the leakage current to check the isolation of...

Open the catalog to page 3
Clamp-on Testers - 4

Leakage Clamp-on Testers 30032A b Can measure leakage AC currents of 1mA b Filter function can cut off harmonics-currents components from 2nd order b Filter function select on or off b Can measure leakage AC currents of 1mA b Standard AC Leakage model Zero correction 3 mA range: Displays 0.000 mA (zero) when 0.010 mA < I 30 A range: Displays 0.00 A (zero) when 0.05 A < I ˾General Specifications Parameter Method Display Specification Mean-value detection and rms-value calibration LCD (Digital reading 3200 counts) Bar graph (32 segments) Range swiching Range selection Auto or Manual Data Hold...

Open the catalog to page 4
Clamp-on Testers - 5

b Light weight & compact design b Mean value display b Data hold function b Approved for comformity to safety standards EN61010-1, b Mean value display b Data hold function b Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V) ˾Specifications Parameter AC current At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) ˾General Specifications Parameter Method of detection Display Response time Range switching Data hold Operating temperature and humidity Temperature coefficient Effect of external magnetic field Effect of conductor position Safety standard...

Open the catalog to page 5
Clamp-on Testers - 6

b True RMS Display b Data hold function b Approved for comformity to safety standard EN61010-1, b Mean value display b DC output function b Data hold function b Sleep function b Approved for comformity to safety standards EN61010-1, ˾Specifications Parameter AC current At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) AC voltage Crest factor Resistance At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) ˾General Specifications Parameter Method of detection Display Response time Specification True RMS LCD(Digital display:1999 counts) Approx. 1 second (approx. 2 seconds on...

Open the catalog to page 6
Clamp-on Testers - 7

b Light weight & compact design b Mean value display b Sleep function b Approved for comformity to safety standards EN61010-1, b True RMS display b DC output function b Data hold function b Sleep function b Approved for comformity to safety standards EN61010-1, At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) ˾General Specifications Parameter Method of detection Display Response time Range switching Data hold Operating temperature and humidity Temperature coefficient Effect of external magnetic field Effect of conductor...

Open the catalog to page 7
Clamp-on Testers - 8

b Mean value display b Sleep function b Data hold function b Approved for comformity to safety standards EN61010-1, b True RMS display b Sleep function b Data hold function b Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V) ˾Specifications Parameter AC current DC current AC voltage DC voltage Crest factor Resistance Frequency At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) Parameter DC current AC current DC voltage AC voltage Resistance DC output ˾General Specifications Parameter Specification Method of detection True RMS...

Open the catalog to page 8
Clamp-on Testers - 9

Leakage Clamp-on Testers b True RMS display b Sleep function b Data hold function b Approved for comformity to safety standards EN61010-1, b Mean value display b Auto power-off b Manual range switching b Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V) ˾Specifications Parameter DC current AC current At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) Crest factor Resistance Frequency DC output At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) ˾General Specifications Parameter Method of detection Display...

Open the catalog to page 9
Clamp-on Testers - 10

Leakage Clamp-on Testers CL340 b True RMS display b Auto power-off b Manual range switching b Approved for comformity to safety standards EN61010-1, b Mean value display b Auto power-off b Manual range switching b Approved for comformity to safety standards EN61010-1, At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) Effect of conductor position Effect of residual current Safety standard Circuit voltage Withstanding voltage Power supply Battery life Consumed current Auto power-off Diameter of measurable conductor Dimensions Weight Accessories ˾General Specifications ˾General...

Open the catalog to page 10
Clamp-on Testers - 11

Leakage Clamp-on Testers Clamp-on Testers b Compact and light with high-performance b 20Hz to 20kHz wide frequency characteristics b Can be connected to a digital multimeter b Need not be connected to a power source b Fit to waveform measurement using oscilloscopes and oscillographic b Approved for conformity to safety standards EN 61010-1, recorders ˾Specifications ˾Specifications Parameter At 23;Ȁ5;, 75%RH or less Accuracy:Ȁ(% of reading + digits) Measuring range Output voltage Accuracy (at 23;Ȁ5;, sine wave input) 0 to 400 A ACrms (600 A peak) 0 to 4 V ACrms (10mV/A) Ȁ1.5% of rdg Ȁ0.4mV...

Open the catalog to page 11

All YOKOGAWA Europe catalogs and technical brochures

  1. YS1500

    20 Pages

  2. UM33A/S006

    2 Pages

  3. YTA610

    20 Pages

  4. FA-M3V

    19 Pages

  5. RAMC

    24 Pages

  6. TB750G EXAxt

    3 Pages

  7. OX400

    2 Pages

  8. MW100

    5 Pages

  9. FieldMate

    5 Pages

  10. AMADAS

    4 Pages

  11. Exapilot

    5 Pages

  12. Exaquantum

    5 Pages

  13. BUAQ7280-01

    12 Pages

  14. BU7603_00E_060

    20 Pages

  15. BUAQ2200

    8 Pages

  16. ADMAG Series

    9 Pages

  17. Exaplog

    2 Pages

  18. AAASuite

    2 Pages

  19. InfoWell

    8 Pages

  20. VTSPortal

    2 Pages

  21. U33Q01A01-01E

    11 Pages

  22. BU33K01A01-50E

    11 Pages

  23. CENTUM.VP

    11 Pages

  24. ADMAG AXF

    2 Pages

  25. YTA series