39 PLUG-IN RELAYS FOR ELECTRIC POWER RATINGS AND SPECIFICATIONS COIL SPECIFICATIONS RB-2PET1C RB-2PET1C RB-2PET2C RB-2PET6C RB-2PET6HC RB-2PET7C RB-2PET7HC RB-2PET2C RB-2PET6C RB-2PET6HC 1NO 12VDC 12VDC 24VDC 48VDC 110VDC 24VDC 48VDC 110VDC 26 50 50 27 13 48 29 14 0.35 0.7 1.3 2.5 1.2 1.4 2.7 150%E 150%E 150%E 150%E 150%E 150%E 75%E or less 75%E or less 75%E or less 65%E or less 75%E or less 68%E or less 10%E or greater 10%E or greater 10%E or greater 8.5%E or greater 10%E or greater 8.5%E or greater 1NO1NC 2NO 2NC R15 115VDC 20A (L/R†5ms), Current-Carrying Time: 0.5s 240VAC 30A (PF=0.7) 115VDC 0.5A (L/R=100ms) 240VAC 1A (PF=0.4) RB-2PET7C RB-2PET7HC 5ms or less 5ms or less 5ms or less 3ms or less 3ms or less 5ms or less 7ms or less 19.6m/s2 {2G} (10 to 150Hz) 147m/s2 {15G} 294m/s2 {30G} 2200VAC for 1minute, Leakage Current: 5mA (Across Open Contacts: 1000VAC) 100MΩ or greater (with 500VDC Megger) -40 to +80Ž -20 to +60Ž -20 to +50Ž -20 to +60Ž -20 to +50Ž 140g Refer to page 7. Contact Arrangement Rated Insulation Voltage 250VAC (Power Frequency) Incorporated Bestact Making Capacity Breaking Capacity Other Contact Performance Operating Time Releasing Time Insulation Resistance Approx. Weight Type Type Rated Voltage (E) Rated Current (mA) Operating Voltage Releasing Voltage Characteristics Contact Ratings Note: @1. Values of ratings and specifications tabulated above are the ones at ambient temperature of 20Ž. –2. Values of vibration/shock resistance are obtained when Bestact is equipped with a relay retaining band. Note: @1. Coil specifications tabulated above are the ones at ambient temperature of 20Ž. –2. Coil rated current can vary ±10%. –3. Continuous allowable voltage is the value which can be applied infrequently within 3 hours. Relays incorporating NC contact may erroneously operate if the continuous allowable voltage is exceeded even for a short time. NO contact: 3ms or less NC contact: 7ms or less Type RB-2PET@C Vibration Resistance*2 *2 *3 *2 Erroneous Operation Breakdown Shock Resistance Withstand Voltage (Power Frequency) Operating Temperature Storage Ambient Temperature Rated Power Consumption (W) Continuous Allowable Voltage

pageCatalog pdf di En 2012-06-22-01