29 COIL SPECIFICATIONS AMBIENT TEMPERATURE AND OPERATING VOLTAGE (DC Coil) DIMENSIONS in mm ・Plug-in Type RB-3PC ・Plug-in Type RB-3PC ・Stationary Type RB-5ABEC ・Stationary Type RB-5ABEC ・Plug-in Type RB-3PC (Ambient temperature 20℃) ・Stationary Type RB-5ABEC (Ambient temperature 20℃) Note: Minimum allowable voltage under no load. Note:  1. When Type RB-3PC and RB-5ABEC are used in a DC circuit, connect the even-numbered terminals to G and odd-numbered terminals to F.  2. When mounting relays in parallel, provide a mounting interval of 42mm or greater. Note: 1. Do not change the contact arrangement. Otherwise, the operating characteristics may change. 2. The unit is color-coded as follows: Gray: NO contact unit, coil terminal units and idle unit. Yellow: NC contact unit. 3. When mounting the relays in parallel, provide a mounting interval of 50mm or greater. Rated Voltage (E) V Rated Power Consumption Minimum Operating Voltage NO contact 68%E or less NC contact 82%E or less NO contact 72%E or less NC contact 82%E or less NO contact 75%E or less NC contact 78%E or less NO contact 76%E or less NC contact 78%E or less 15%E or greater 10%E or greater Release Voltage Operating Characteristics 100 (AC) 200 (AC) Approx. 2VA Approx. 2.8VA Approx. 1.9W Approx. 3W 24 (DC) 48 (DC) 100 (DC) 200 (DC) 130%E 130%E 2.2 to 2.7 VA 2.2W 2.3W 1.0 OPERATING VOLTAGE (WHERE RATED OPERATING VOLTAGE: 1.0) OPERATING VOLTAGE (WHERE RATED OPERATING VOLTAGE: 1.0) 0.8 0.6 0 20 AMBIENT TEMPERATURE (℃) AMBIENT TEMPERATURE (℃) MIN. ALLOWABLE VOLTAGE OF NC CONTACT MIN. ALLOWABLE VOLTAGE OF NO CONTACT MIN. ALLOWABLE VOLTAGE OF NC CONTACT MIN. ALLOWABLE VOLTAGE OF NO CONTACT 40 60 80 1.0 0.8 0.6 0 20 40 60 80 31 2-M3 to H3.5 SCREW HOLES 66.5 (87.5) (78) (94.5) 4.5 36 UP 32 8 7 6 5 2 3 4 39 49 2-3. 6DIA. MTG HOLES (HEIGHT: 17mm) 2-4ラ5 MTG HOLES (HEIGHT: 21mm) 37 34 14 21 SOCKET TP38S (SCREW TERMINAL M3.5ラ11) LED 2NO1NC Symbols and Terminal marking Vibration proof Band (Attached to Socket) Vibration proof Band (Attached to Socket) CASE DIMENSIONS 32 CASE DIMENSIONS 3NO MTG HOLE DIMENSION 31 66.5 Approx. 97 TH35-7.5: Approx. 99.5 TH35-15: Approx. 107 14 26 (92.5) 41 8 7 6 2 3 4 5 39 4.5 52 LED SOCKET TP38S (SCREW TERMINAL M3.5ラ10) 35mm WIDTH DIN RAIL APPLIED Correct MTG Direction 93.3 39.6 25 86 75 50mm OR GREATER PARALLEL MTG COIL TERMINAL UNIT LED M4ラ11 2-4. 8DIA. MTG HOLES 8%E or greater 8%E or greater 100AC 200 24DC 48 100 200 130%E 130%E 2.6W Note:  1. All the products are available as custom-order products (Plug-in type and Stationary type). *2. Maximum allowable voltage is the maximum value that can be applied to the coil in consideration of its thermal degradation and insulators in the relays. This is not a continuous allowable voltage. The relay incorporating NC contact may erroneously operate if the maximum allowable voltage is exceeded even for a short time. Maximum Allowable Voltage*2 Maximum Allowable Voltage*2 Rated Voltage (E) V Rated Power Consumption Minimum Operating Voltage Release Voltage Operating Characteristics Follow the mounting directions as shown in the diagram. 2-M3 to H3.5 SCREW HOLES MTG HOLE DIMENSION

pageCatalog pdf di En 2012-06-22-01