| | | Bestact™ Heavy-duty Reed Switches | | |
| | | |
| | | |
| | | Highly Reliable Contact Employing New Materials and Innovative Designs such as wiping and Hammering Action, Bifurcated contact and Back-stop Mechanism_ | | |
| | | |
| | | ■ FEATURES 1 Sealed with an inert gas, ensuring freedom from aging and influences exerted by external environment. 2 The bifurcated contact and "wiping action" assures outstanding contact reliability, probability offailure isextremely low. I60=4.6x 10-9(24V 1mA) 3 Quick action permits a larger make and break capacity and longer service life. 4 Can switch both AC and DC, permitting direct control over a wide range from low level load to electromagnetic power load. 5 Near surge-less switching of inductive load. | | |
| | | Medium-capacity type: 24V 1mA to 240VAC 0.5A (5A making) Contact Ratings: C300 (AC) and Q150 (DC) 180VA & 69VA respectively Large-capacity type: 24V 1mA to 240VAC 1A (10A making) 230VDC 40W (Solenoid valve) Contact Ratings: C600, B300 (AC), Q300 (DC), _360VA & 69VA respectively_ | | |
| | | |
| | | |
| | | RELIABILITY AND TYPICAL APPLICATIONS | | |
| | | ■ CONSTRUCTION AND OPERATING MECHANISM Conventional reed switches are constructed simply. The contact for switching current also serves to switch the magnetic circuit. Bestact uses a separate magnetic member and contact unit (current carrying arcing section), each using different materials and design optimized for their functions. | | |
| | | |
| | | (Field Failure Rate of" Relays) | | |
| | | ■ Electric power equipment, nuclear power facilities ■ Elevators ■ Low-level command and control switches ■ Waterworks equipment | | |
| | | |
| | | |
| | | GENERAL PURPOSE RELAY 100TO150 / SOLID STATE RELAY 80 TO 100 / I. / MERCURY RELAY
| | |
| | | ■ Industrial automatic control systems ■ PLC interface devices ■ Transportation equipment and devices ■ Water treatment plants ■ Continuous casting machines ■ Non-contact safety switches ■ Transit vehicle & railway ■ Cylinder position detection switches | | |
| | | |
| | | <Bestac1 (Large^capacity lype) > | | |
| | | |
| | | |
| | | |
| | | 50 TO 60 / | | |
| | | ■ Over-current detection switches ■ Motor vehicle electrical instrument "2 [ / BESTACT RELAY Note:*1. Excerpt from "Reliability Data" issued by government agency *2. Actual results of field failure rate.. J 44.8 v *3. When no. of failures is zero apply following formula: — No. of failures x Constant** | | |
| | * | |
| | | |
| | | Note: -Wvxng action when orwralrng (Step!1—$'1 * Hammer dtg adion when | | |
| | | |
| | | Ä60 = | | x-10-- | | |
| | | |
| | | No. of tested contacts x tested hour (H) ** Applying 60% reliability level, 0.917 for zero failure. | | |
| | | |
| | | |
| | | RATINGS AND SPECIFICATIONS | | |
| | | |
| | | | | | | | | | | | | | Application | Medium-Capacity Type | Large-Capacity Type | Remarks | | | | Type | R25U | R15U | | | | | Contact Arrangement | 1 NO | 1 NO | | | | | | Rated Continuous Current | 3A | 5A | | | | | | Rated conditional short-circuit current | Ratings of short-circuit protection device; 5A250V, quick acting fuse type | In accordance with IEC 62246-2, 3.31 | | | | | Rated | AC-15 | 240V0.5A(180VA,1/4HP) | 240V 1A(360VA, 1/2 HP) | NEMA pilot duty horsepower | | | | | Operational Current*1 | DC-13 | 115V0.3A(69VA) L/R = 40ms | 115V 0.5A, 230V 0.2A (69VA) L/R= 100ms | NEMA pilotduty | | | | | Maximum Making Current | 240VAC 15A | 240VAC 30A | Min. 10 making cycles in accordance with IEC 62246-2, 3.34 | | | | Contact | | | 240VAC 15A | 240VAC 30A | Min. 10 breaking cycles in accordance with IEC 62246-2, 3.35 | | | | Performance | Maximum Breaking Current | 115VDC 0.5A (L/R = 40ms) | 115VDC 0.6A (L/R = 100ms) 230VDC 0.4A (L/R = 100ms) | | | | | Minimum Operational Power Ratings | 24V 1mA (5V 1mA digital load) | 24V 1mA (5V 1mA digital load) | In accordance with IEC 62246-2, 3.32 | | | | | Withstand Voltage across Contacts | 500VAC 1minute | 800VAC 1minute | | | | | | Insulation Resistance | 109Q orgreater | 109Q orgreater | With 500VDC megger | | | | | Initial Contact Resistance | 500m Q orless | 500m Q orless | 6VDC1A | | | | | Capacitance | 0.5PF or less | 0.45PF or less | | | | | | Pick-up Ampere Turn | 100to 130AT | 180to230AT | Standard coil is 3000turns, 33.5 mm long, | | | | Operational Characteristics | Drop-out Ampere Turn | 50AT or greater | 60AT or greater | 10.5mm I.D. with 0.2mm dia. wire. | | | | Operating Time | 4ms or less (Bounce not included) | 4ms or less (Bounce not included) | at 150% of pick-up ampere turn | | | | Releasing time*2 | 2ms or less | 2ms or less | Using standard coil | | | | | Maximum Bounce Time | 2ms | 2ms | | | | | | Mechanical life | Over100,000,000 operations | Over100,000,000 operations | In accordance with IEC 62246-2, 3.24 | | | | Mechanical Performance | Vibration Resistance | 147.0m/s2 (15G) or greater | 196.0m/s2 (20G) or greater | 20 to 1 000Hz | | | | Impact Resistance | 196.0m/s2 (20G) orgreater (980.0m/s2 (100G) orgreater) | 392.0m/s2 (40G) orgreater (980.0m/s2 (100G) or greater) | Value in parenthesis indicates breakdown G. | | | | | Robustness ofterminals | 98.0N (10kgf) | 98.0N (10kgf) | | | | | Ambient | Operational Temperature | -50to+150°C | -50to +150C | | | | | Temperature | Storage | -60to+180°C | -60to +180C | | | | | | | | | | | | | | |
| | | |
| | | Note: *1. Where 240VAC, the rated operational current of 1A means 10A making and 1A breaking. Where 115VDC is indicated, the current is set at 1 times this value. *2. The releasing time indicates the value when the coil is equipped with a flywheel diode. | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |