AUTOMATION GmbH Automation System for high requirements of technology especially for outdoor applications

 Open the catalogue to page 1

The automation system for outdoor use Areas of application Due to its technical qualification, transCON can be used economically in all types of large-capacity and public vehicles and in areas with increased requirements. Examples include: Track vechicles Construction vechicles (excavators, cranes) Special-purpose vechicles (Fire engines, dustbin carts) Buses Locations in outdoor installations or under hall ceilings… Ships Typical applications in vechicles are: Management of cabin information Control of drive mechanism Engine management Door control Control of air conditioning systems Brake control...

 Open the catalogue to page 2

We begin where others stop! State of the Art transCON has been developed using the latest technology. When selecting the components and system design, a highly qualified team of engineers ensured that the latest technical developments in electronics and semi-conductor technology were used wherever possible. transCON therefore stands out due to the following features: An extremely compact design with a maximum level of performance Exceptionally high computing capacity of the CPUs Very fast system throughput Extreme high level of accuracy and reliability Suitable for railway applications transCON...

 Open the catalogue to page 3

□ Suitable for locations where space is at a □ Can be used in signal networks of 24 V DC. Other voltages available on request. It has therefore gained world-wide □ Modular housing, width 22.5 mm, for Satisfies extensive requirements □ In extreme environmental conditions - suitability for railway applications in □ Use of modern integrated components □ Optimum number of channels per □ All signal terminals and electronic PCBs have plug-in connections □ PLCI with local I/O □ Remote fieldbus I/O nodes □ Simple adaptation to other programming Subject to technical modifications

 Open the catalogue to page 4

Technical properties Technical properties on one CAN bus enables almost unlimi- □ Other field buses are: Profibus DP □ Signal capacity per I/O nodes on the CAN □ Type 80 binary input/output signals or □ Type 40 analogue input signals or □ Type 20 analogue output signals or □ Mixture of binary and analogue signals □ Rapid and cost-effective installation and □ Secure locking of the I/O block using end Process signals □ Analogue standardised signals for inputs □ Screw or spring-loaded terminals, max. Electrical Isolation □ The process signals against to the □ The signal groups against each other Optimised,...

 Open the catalogue to page 5

Communication Module Description Communication Module Bus Coupler CANopen Display of operating modes Send Tx: LED yellow Receive Rx: LED yellow Power ok: LED yellow Error CAN: LED red System data Maximum number of nodes Transmission medium Parameter settings via rotary swith Maximum network expansion Baud rate Processing speed Addressing of the Ethernet TCP/IP Bus connection Technical data Device profile Number of I/O modules per node CPU Type Memory Address setting Operating system Power consumption Operating voltage Equipotential insolation Insolation voltage Basic norms Data interfacing Earthing Connection...

 Open the catalogue to page 6

Approvals: CE, Railway norm EN 50155 Type PLC-CANopen Display of operating modes Send Tx: Receive Rx: Power ok: Error CAN: System data Working implementation When using the PLC-CANopen and the Linux, transCON achieves unsurpassed performance levels in processing speed, memory size and connection capability via buses. In addition to programming in accordance with IEC 61131, other high-level languages and ANSI-C can be implemented. Apart from Linux, the following operating systems are available: VxWorks, Windows CE, PSOS, QNX, eCos or Linux RT. Yello LED Yello LED Yello LED Red LED Maximum number...

 Open the catalogue to page 7

Power Supply The module converts a disrupted, non-stabilised direct voltage into the stabilised supply voltages of 5 V DC and 3,3 V DC. Then supply of the connected modules is carried out via the internal greenbus. Approvals: CE, Railway norm EN 50155, GL Description Power Supply Betriebsartenanzeige: Power ok: Error: Short circuit Low voltage System data Input voltage range Output voltage Maximum output current Reverse polarity protection Equipotential isolation Processing speed Addressing of the Ethernet TCP/IP 24 V DC -30%/+35%; -40% (100 ms); -100% (10 ms) 5 V DC; 3,3 V DC 2 A (5 V); 1,6 A...

 Open the catalogue to page 8

Binary Input Module The module offers 8 binary inputs. Each channel is isolated against the others as well as the system electronics. The continuous input current of 7 mA guarantees a high level of contact stability even in polluted environments (fritting effect). This is available as a continuous current so that a high level of signal reliability is also ensured in the event of vibrations. Due to the potential-free design, the inputs can be switched in series and used for positive or negative switching (current source and current sink). 8 Binary inputs 24V DC positive or negative switching Approvals:...

 Open the catalogue to page 9

Binary Output Module The module offers 8 binary outputs. Each channel is isolated against the others as well as the system electronics. An external power supply for the electrically isolated circuits is not necessary. Due to the potential-free design, the outputs can be switched in series and used for positive or negative switching (current source and current sink). 8 Binary outputs 24 V DC; 1 A positive or negative switching Dimensions (mm): H x W x D 22,5 x 99,5 x 114,5 Description Binary output module Display of operating modes Error (Greenbus): Power ok: Channel status (high): Approvals: CE,...

 Open the catalogue to page 10

Analog Module The module offers analogue inputs and outputs for standard voltages and currents. A common reference potential is defined as well as the electrical isolation against the system electronics. The choice between current or voltage inputs is carried out via plug-in jumpers. 4 analogue inputs / 2 analogue outputs 0 (4)-20 mA, 0-10 V, +/-10 V Dimensions (mm): H x W x D 22,5 x 99,5 x 114,5 Description Analog input/output module Display of operating modes Error LED (Greenbus): Power LED: Approvals: CE, Railway norm EN 50155, GL Type System data Number of inputs Number of outputs Operating...