You may also be interested in
Linear power supply, Power supply adapter, Open frame power supply, DIN rail power supply, Power supply module
Text version of the page
200 Wattsxppower.comPBM200 Series•Worldwide Medical Approvals•Single, Dual, Triple and Quad Outputs•Small Size - Only 7” x 4” x 1.5”•Power Fail Detect & Remote On/Off•Universal AC Input with Active PFC•High Reliability - 350k Hours MTBF•100 Watt Convection-Cooled RatingAC-DCSpecificationInput GeneralInput Voltage •90-264 VAC Efficiency •Up to 80% Input Frequency •47-63 Hz Isolation •4000 VAC Input to Output1500 VAC Input to Ground 500 VAC Output to Ground Input Current •3.2 A rms at 115 VAC, 1.6 A rms at 230 VAC Switching Frequency •100 kHz ±12 kHz Power Density •4.76 W/In Inrush Current •20 A at 115 VAC, 40 A at 230 VACcold start 25 ºC3 Power Factor •0.98 typical Power Fail Detect• ACOK = TTL logic highAC not OK = TTLlogic low Earth Leakage Current •90 µA max at 115 VAC, 60 Hz150 µA max at 230 VAC, 50 Hz MTBF •350 kHrs per MIL-HDBK-217F at +25 ËšC Input Protection •Both line and neutral fused Environmental OutputOperating Temperature •0 ËšC to +70 ËšC, derate linearly from 100%power at +50 ËšC to 50% power at +70 ËšC Output Voltage •See table Output Voltage Trim •Not user-adjustable Cooling •‘C’ versions have internal fan,‘B’ versions are derated with convection cooling or require 25 CFM (see note 4) Initial Set Accuracy •±2% Operating Humidity •Up to 95% RH, non-condensing Minimum Load •See table & note 5 Storage Temperature •-40 ËšC to +85 ËšC Start Up Delay •2 s max Operating Altitude •2500 m Start Up Rise Time •18 ms typical Shock •Half sine pulse. acceleration 50 g, 11 msduration, 3 shocks in each direction, unpackaged, non-operating Hold Up Time •20 ms minimum at full load & 110 VAC Vibration •Sinusoidal 10-55 Hz, amplitude 0.15 mm,30 min/axis, unpackaged, non-operating Drift •±0.2% Line Regulation •±0.5% max Load Regulation •See note 7 Transient Response •4% max deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise •2% max pk-pk, 20 MHz BW with a 22 µF electrolytic & a 0.47 µF tantalum capacitorEMC & SafetyEmissions •EN55011 & FCCClass B conducted & radiated Overvoltage Protection •112-140% Vnom output 1 only, recycleinput to reset Harmonic Currents •EN61000-3-2 Overtemperature •Shutdown at +85 ºC (singles) or +105 ºC Voltage Flicker •EN61000-3-3 Protection (multi outputs) with auto recovery, measured internally ESD Immunity •EN61000-4-2, level 3 Perf Criteria A Overload Protection •140-200% typical, auto recovery Radiated Immunity •EN61000-4-3, level 3 Perf Criteria A Short Circuit Protection •Trip and restart (Hiccup mode) EFT/Burst •EN61000-4-4, level 3 Perf Criteria A Temperature •0.04%/ËšC Surge •EN61000-4-5, level 3 Perf Criteria A CoefficientRemote Sense Conducted Immunity •EN61000-4-6 3 V, Perf Criteria A •Single output models only.Compensates for up to 0.5 V drop Dips & Interruptions •EN61000-4-11, 30% 10 ms,60% 100 ms, >95% 5000 ms, Perf Criteria A, B, B Safety Approvals •EN60601-1, UL60601-1,CSA22.2 No. 601-1 per cUL, CE Mark Remote On/Off •On = Logic low or open circuitOff = Logic high |
|