200 Watts

xppower.com

PBM200 Series

•Worldwide Medical Approvals•Single, Dual, Triple and Quad Outputs•Small Size - Only 7” x 4” x 1.5”•Power Fail Detect & Remote On/Off•Universal AC Input with Active PFC•High Reliability - 350k Hours MTBF•100 Watt Convection-Cooled Rating

AC-DC

Specification

Input General

Input Voltage •90-264 VAC Efficiency •Up to 80% Input Frequency •47-63 Hz Isolation •4000 VAC Input to Output1500 VAC Input to Ground 500 VAC Output to Ground Input Current •3.2 A rms at 115 VAC, 1.6 A rms at 230 VAC Switching Frequency •100 kHz ±12 kHz Power Density •4.76 W/In Inrush Current •20 A at 115 VAC, 40 A at 230 VACcold start 25 ºC
3 Power Factor •0.98 typical Power Fail Detect• ACOK = TTL logic highAC not OK = TTLlogic low Earth Leakage Current •90 µA max at 115 VAC, 60 Hz150 µA max at 230 VAC, 50 Hz MTBF •350 kHrs per MIL-HDBK-217F at +25 ËšC Input Protection •Both line and neutral fused

Environmental Output

Operating Temperature •0 ËšC to +70 ËšC, derate linearly from 100%power at +50 ËšC to 50% power at +70 ËšC Output Voltage •See table Output Voltage Trim •Not user-adjustable Cooling •‘C’ versions have internal fan,‘B’ versions are derated with convection cooling or require 25 CFM (see note 4) Initial Set Accuracy •±2% Operating Humidity •Up to 95% RH, non-condensing Minimum Load •See table & note 5 Storage Temperature •-40 ËšC to +85 ËšC Start Up Delay •2 s max Operating Altitude •2500 m Start Up Rise Time •18 ms typical Shock •Half sine pulse. acceleration 50 g, 11 msduration, 3 shocks in each direction, unpackaged, non-operating Hold Up Time •20 ms minimum at full load & 110 VAC Vibration •Sinusoidal 10-55 Hz, amplitude 0.15 mm,30 min/axis, unpackaged, non-operating Drift •±0.2% Line Regulation •±0.5% max Load Regulation •See note 7 Transient Response •4% max deviation, recovery to within 1% in 500 µs for a 25% load change Ripple & Noise •2% max pk-pk, 20 MHz BW with a 22 µF electrolytic & a 0.47 µF tantalum capacitor

EMC & Safety

Emissions •EN55011 & FCCClass B conducted & radiated Overvoltage Protection •112-140% Vnom output 1 only, recycleinput to reset Harmonic Currents •EN61000-3-2 Overtemperature •Shutdown at +85 ºC (singles) or +105 ºC Voltage Flicker •EN61000-3-3 Protection (multi outputs) with auto recovery, measured internally ESD Immunity •EN61000-4-2, level 3 Perf Criteria A Overload Protection •140-200% typical, auto recovery Radiated Immunity •EN61000-4-3, level 3 Perf Criteria A Short Circuit Protection •Trip and restart (Hiccup mode) EFT/Burst •EN61000-4-4, level 3 Perf Criteria A Temperature •0.04%/ËšC Surge •EN61000-4-5, level 3 Perf Criteria A CoefficientRemote Sense Conducted Immunity •EN61000-4-6 3 V, Perf Criteria A •Single output models only.Compensates for up to 0.5 V drop Dips & Interruptions •EN61000-4-11, 30% 10 ms,60% 100 ms, >95% 5000 ms, Perf Criteria A, B, B Safety Approvals •EN60601-1, UL60601-1,CSA22.2 No. 601-1 per cUL, CE Mark Remote On/Off •On = Logic low or open circuitOff = Logic high