Text version of the page
AC-DC Specification 40-100 Watts • Compact Size - High Power Density • IT, Industrial & Medical Approvals • Convection-cooled • Class I and II Construction • DC Input Version Available (DCM Series) • PoE Isolation Version Available (POE Series) • 3 Year Warranty ECM Series Input Input Voltage • 90-264 VAC (120-370 VDC) Input Frequency • 47-63 Hz; 440 Hz Input Current • 40 W: 0.4 A max at 230 VAC 60 W: 0.6 A max at 230 VAC 100 W: 0.9 A max at 230 VAC Inrush Current • 40 A max at 230 VAC Earth Leakage Current • <125 μA at 115 VAC/60 Hz <210 μA at 230 VAC/50 Hz Input Protection • Internal T3.15 A, 250 V fuse in line and neutral Output Output Voltage • See tables Output Voltage Trim • ±5% on 3.3 V & 5 V versions, ±10% on other single output models and V1 of multi-output models. See note 1 for ECM40/60 models Initial Set Accuracy • ±1.0% V1, ±5% V2, V3 & V4 Minimum Load • See tables Start Up Delay • 1.5 s max Start Up Rise Time • 10 ms max Hold Up Time • 16/75 ms min at 115/230 VAC Line Regulation • ±0.5% Load Regulation • ±1% single output models; ±3% V1, ±5% V2 & V3 ECM40/60 multi-output models. ±1% V1 & V2, ±5% V3 & V4 ECM100 Cross Regulation • 2% on ECM40/60 only Over/Undershoot • None at turn on/off Transient Response • 4% max. deviation, recovery to within 1% in 500 μs for a 25% load change Ripple & Noise • 1% pk-pk, 20 MHz bandwidth Overvoltage Protection • 115-135% Vnom, recycle input to reset Overload Protection • 110-150% on primary power limit, auto recovery Short Circuit Protection • Trip and restart (Hiccup mode) Temperature • 0.05%/°C Coefficient Peak Load • 120% for 100 ms (ECM40/60) see note 3. xppower.com General Efficiency • 80-85% depending on model Isolation • 4000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground Switching Frequency • 70 kHz typical Power Density • 40 W: 4.2 W/In3 60 W: 6.3 W/In3 100 W: 7.4 W/In3 MTBF • 600 kHrs to MIL-HDBK-217F at 25 ΊC, GB Environmental Operating Temperature • 0 °C to +70 °C. Refer to derating curves for specific operating limitations. Cooling • Convection & fan-cooled ratings (see derating curves) Operating Humidity • 95% RH, non-condensing Storage Temperature • -40 °C to +85 °C Operating Altitude • 3000 m Shock • 30 g pk, half sine, 6 axes Vibration • 2 g rms, 5 Hz to 500 Hz, 3 axes EMC & Safety Emissions • EN60601-1-2, EN61204-3, FCC 20780, EN55022 & EN55011, level B conducted EN55022 Level A radiated Harmonic Currents • EN61000-3-2 Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, 10 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, 10 V Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B EN60601-1, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, Perf Criteria A, A (with 50% load), A, B Safety Approvals • EN60950, UL60950, CSA 22.2 601.1, EN60601-1, UL60601-1 ECM40 & ECM60: SEMI F47

pageCatalog pdf di En 2012-06-22-01