You may also be interested in
Hot-swap power supply, Converter, LED driver, DIN rail power supply, Power supply adapter
Text version of the page
40-60 Wattsxppower.comACS Series•Low Cost•Small Size•Universal Input•Rugged Design•High MTBF•International Safety Approvals•Covered Versions AvailableAC-DCSpecificationInput GeneralInput Voltage •90-264 VAC (110-370 VDC) Efficiency •See tables Input Frequency •47-63 Hz Isolation •3000 VAC Input to Output1500 VAC Input to Ground 500 VAC Output to Ground Input Current •ACS40:0.45 A rms at 230 VACACS60:0.60 A rms at 230 VAC Switching Frequency •50-70 kHz MTBF •230 kHrs per MIL-HDBK-217F Inrush Current •Cold start at 25 ºC:25 A at 115 VAC,50 A at 230 VAC Earthing •Class IEnvironmental OutputOperating Temperature Storage Temperature •0 ºC to +70 ºC, derate from full load at+50 ºC to half load at +60 ºC. Reduce both temperatures by 10 ºC when cover is fitted •-40 ºC to +85 ºC Output Voltage •See table Output Voltage Trim •±5% Hold Up Time •8 ms typical at full load Line Regulation •0.5%max at full load Load Regulation •1.0% max at 10% load to full loadEMC & SafetyRipple & Noise •1% max pk-pk, 20MHz BW Emissions •FCC20780 Level B, CISPR22 (EN55022),level B conducted Overvoltage Protection •Typically 130% of max output Overcurrrent Protection •120% typical ESD Immunity •EN61000-4-2, level 3 Perf Criteria A Radiated Immunity •EN61000-4-3, 10 V/m Perf Criteria A EFT/Burst •EN61000-4-4, level 2 Perf Criteria A Surge •EN61000-4-5, level 3 Perf Criteria A Conducted Immunity •EN61000-4-6, 10 V Perf Criteria y Safety Approvals •EN60950, UL1950, CSA22.2 No. 2341 |
|