• Resolves Key Compliance Issues. Provides for 100% sampling to improve quality
and overall process integrity
• Non-Destructive. Non-contact operation eliminates risk of damage and waste
• Fully Automated. No need for additional resources
• Integrates In LIne. Works in combination with industrial robot (6 axis)
• Full Part Coverage. Multiple angles of measurement, from 15º to 75º performed
simultaneously to ensure complete part evaluation
• Collects Essential Data. In addition to colormetric information, system
includes non-contact, orange peel detection and surface temperature data
with each measurement
CarFlash System Advantages
Specifications
X-Rite is a world leader in providing global color control solutions for manufacturing and quality management
requirements.
We lead the industry in offering service options to ensure uninterrupted performance of all X-Rite products. Training
and educational resources are available globally and online for both new and experienced users to optimize their
color measurement capabilities.
Visit xrite.com for more information about X-Rite products. X-Rite customers worldwide may also call the
Applications Support team at CASupport@xrite.com or Customer Service at 800-248-9748.
X-Rite: Your source for accurate color. On time. Every time.
Measuring Geometrics
45o illumination
15o, 25o, 45o, 75o aspecular viewing
Grating spectrometer technology
Distance to object surface: 35mm
Measuring Area
8mm x 17mm
Light Source
Xenon-flash lamp
Illuminant Types
D65, 10o
Spectral Interval
31 band spectral measurement
10nm interval from 400nm – 700nm
15nm bandwidths
Measurement Range
0 to 300% reflectance
Measurement Time
Approx. 3.0 seconds
Inter-Instrument Agreement
0.20 ÄE* avg. on reference
BCRA tile set
0.40 ÄE* max. on any chromatic tile
0.15 ÄE* max. on any grey tile
Short-Term Repeatability
0.10 ÄE*abon white ceramic
Lamp Life
Approx. 500,000 measurements
Orange Peel Digital frame
processing system for analyzing
an IR light pattern that is
projected onto the painted
surface
Data Storage (five angles)
ASCII-file
Data Interface
Ethernet, Fieldbus (PROFIBUS)
Operating Temperature Range
15º to 35ºC 85% relative
humidity max. (non-condensing)
Weight
16.5lbs. (7.5kg)
Dimensions
175mm H, 255mm W, 305mm L
Accessories Provided
Calibration standards, interface
box, PC, operation manual
IR Surface Temperature
Surface temperature: 15 – 150oC
Temperature resolution ±0, 1oC
Environmental temperature 15o – 35oC
Ultra Sonic Distance Sensor
To define the distance to the
surface in z-direction, +100mm
to -15mm (referring to the
measuring point coordinates)
Positioning Requirements
Gloss degree of surface > 65
reflector meter units (20o)
Surfaces’ radius of curvature
> 100mm, < -400mm
70mm x 70mm measuring area