For information visit www.WTW.com for a customer care center near you or inside US: call WTW 800 645 5999. Te c h n i c a l D a t a OA 110 Standard 1 Standard 2* Measuring Ranges NH4-N: 0.1 ... 1000 mg/l; 0.01 ... 71.00 mmol/l NH4-N: 0.05 ... 10 mg/l; 0.005 ... 0.71 mmol/l* NH4+: 0.1 ... 1280 mg/l; 0.01 ... 71.00 mmol/l NH4+: 0.05 ... 12.8 mg/l; 0.005 ... 0.71 mmol/l* Resolution (Display) Range: 0.10 ... 10 mg/l: 0.01 mg/l 10.0 ... 100 mg/l: 0.1 mg/l 100 ... 1000/1280 mg/l: 1 mg/l Range: 0.05 ... 10 mg/l: 0.01 mg/l* Accuracy ±5% of the measured value ±0.2 mg/l at <1 mg/l NH4-N ±5% of the measured value ±0.1 mg/l at 1.0 … 100 mg/l NH4-N ±5% of the measured value ±0.05 mg/l at <1 mg/l NH4-N* ±5% of the measured value ±0.1 mg/l at 1.0 … 10 mg/l NH4-N* Coefficient of Variation of Method Range: 0.10 ... 10 mg/l: 3% 10.0 ... 100 mg/l: 4% 100 ... 1000/1280 mg/l: 5% (values for calibration with suitable standard solutions) Response time < 3 min (after alternation in concentration at module input) Measuring Interval Continuous Mode and 10, 15, 20, 25, 30 min interval selectable, AutoAdapt, Interval-Program Calibration Automatic 2-point calibration (AutoCal) with two standard solutions Sample input Approx. 0.3 l/h, solids content < 50 mg/l Consumption Reagent, 10 l: 14/30/50 days at measuring intervals cont./20/30 min Standard solutions A/B, 1.5 l: 60 days with 24 Std. calibration interval Cleaning solution 1.5 l: 60 days with 24 Std. cleaning interval Maintenance Interval Every 6 months Guaranty 2 years for defects of quality O r d e r i n g I n f o r m a t i o n Order No. OA 110 Separate TresCon® analyzer module for ammonium-nitrogen for extension of an existing TresCon® system (requires 1 measuring place) 820 008 TresCon® A 111 TresCon®-basic instrument with analysis module OA 110 for ammonium-nitrogen (wall mounting, space for 2 further modules) 8A-10030 TCU/A111 TresCon® Uno ammonium: single parameter system ammonium with analysis module OA 110 for ammonium-nitrogen 820 101 Accessories and consumables see brochure “Product Details” * around calibration standard IP 54 On-line ammonium measurement • Continuous ammonium value monitoring in sewage plant effluent • Analysis of the ammoniumnitrogen pollution in surface waters • Monitoring water treatment plants • Continuous measurements • Automatic calibration • Short response time TresCon® OA 110 2 Year Warranty Measuring Principle The continuous determination of ammonium in the OA 110 module is carried out according to the potentiometric measuring principle with a gas-sensitive NH3 electrode. Sodium hydroxide is added to the thermostatted sample to convert the ammonium dissolved in the medium into undissociated ammonia gas. The gaseous ammonia alters the pH registered by the measuring electrode; the alteration is a direct measure of the ammonium concentration in the sample. 48

pageCatalog pdf di En 2012-06-22-01