Text version of the page
Heat Dissipation Capacity
Water Flow (minimum)
M
Coolant Inlets/Outlets
AIR VOLUME/ ENGAGEMENT
Max Slip Speed
Max Disengaged Speed
WEIGHT ANDINERTIA
New
Worn
Total Weight
Hub&DP Weight
Hub&DPInertia
Hp
kW
gpm
L/min
qty
size (npt)
in3
L
in3
L
rpm
rpm
lb (kg)
lb (kg)
lbftz(wrz) (kgm2(J))
120
89.5
12
45.4
4
1/2-14
59
1.0
122
2.0
850
1,560
834 (378)
84 (38)
22.4 (0.94)
120
89.5
12
45.4
4
1/2-14
69
1.1
122
2.0
850
1,560
842 (382)
162 (73)
44.8 (1.89)
240
179.0
24
90.8
8
1/2-14
69
1.1
122
2.0
850
1,560
1,006 (456)
176 (80)
45.2 (1.91)
240
179.0
24
90.8
8
1/2-14
78
1.3
122
2.0
850
1,560
1,014 (460)
265 (120)
68.4 (2.88)
240
179.0
24
90.8
8
1/2-14
88
1.4
122
2.0
850
1,560
1,143 (518)
339 (154)
90.6 (3.82)
360
268.5
36
136.3
12
1/2-14
78
1.3
122
2.0
850
1,560
1,202 (545)
279 (127)
68.8 (2.90)
360
268.5
36
136.3
12
1/2-14
88
1.4
122
2.0
850
1,560
1,210 (549)
354 (161)
91.0 (3.84)
360
268.5
36
136.3
12
1/2-14
88
1.4
122
2.0
850
1,560
1,309 (594)
428 (195)
113 (4.77)
480
357.9
48
181.7
16
1/2-14
88
1.4
122
2.0
850
1,560
1,374 (623)
368 (167)
90.9 (3.83)
270
201.3
27
102.2
4
3/4-14
170
2.8
299
4.9
640
1,170
1,700(771)
202 (92)
72.2 (3.04)
270
201.3
27
102.2
4
3/4-14
190
3.1
299
4.9
640
1,170
1,971 (894)
406 (184)
139 (5.85)
540
402.7
54
204.4
8
3/4-14
190
3.1
299
4.9
640
1,170
2,050 (930)
441 (200)
148 (6.24)
540
402.7
54
204.4
8
3/4-14
209
3.4
299
4.9
640
1,170
2,292 (1040)
611 (277)
213 (8.99)
540
402.7
54
204.4
8
3/4-14
228
3.7
299
4.9
640
1,170
2,540 (1 152)
798 (362)
309 (13.0)
810
604.0
81
306.6
12
3/4-14
209
3.4
299
4.9
640
1,170
2,391 (1085)
646 (293)
223 (9.38)
810
604.0
81
306.6
12
3/4-14
228
3.7
299
4.9
640
1,170
2,608 (1 183)
833 (378)
286 (12.1)
810
604.0
81
306.6
12
3/4-14
228
3.7
299
4.9
640
1,170
2,856 (1295)
1,012 (459)
350 (14.7)
1,080
805.4
108
408.8
16
3/4-14
228
3.7
299
4.9
640
1,170
3,783 (1716)
869 (394)
295 (12.5)
650
484.7
65
246.1
4
1-1/4-11 1/2
271
4.4
661
10.8
425
775
2,876 (1305)
493 (224)
305 (12.9)
650
484.7
65
246.1
4
1-1/4-11 1/2
313
5.1
661
10.8
425
775
5,440 (2468)
967 (439)
676 (28.5)
1,300
969.4
130
492.1
8
1-1/4-11 1/2
313
5.1
661
10.8
425
775
4,203 (1906)
986 (447)
610 (25.7)
1,300
969.4
130
492.1
8
1-1/4-11 1/2
355
5.8
661
10.8
425
775
6,978 (3165)
1,460 (662)
1,046 (44.1)
1,300
969.4
130
492.1
8
1-1/4-11 1/2
396
6.5
661
10.8
425
775
8,175 (3708)
1,911 (867)
1,347 (56.8)
1,950
1454
195
738.2
12
1-1/4-11 1/2
355
5.8
661
10.8
425
775
5,545 (2515)
1,479 (671)
915 (38.6)
1,950
1454
195
738.2
12
1-1/4-11 1/2
396
6.5
661
10.8
425
775
7,766 (3523)
1,930 (876)
1,412 (59.5)
1,950
1454
195
738.2
12
1-1/4-11 1/2
396
6.5
661
10.8
425
775
9,401 (4264)
2,360 (1071)
1,643 (69.2)
2,600
1939
260
984.2
16
1-1/4-11 1/2
396
6.5
661
10.8
425
775
7,981 (3620)
1,957 (888)
1,216 (51.2)
NOTES:
*WC=Water Cooled Drive Plates AC=Air Cooled Drive Plates "Minimum pressure required to fully release brake. Springs can be removed to lower the minimum release pressure (lower torque ratings will result). Contact WPT Engineering for details. Maximum allowable air pressure is 130 psi (9 bar).
The thermal ratings listed require a water flow of one gallon per minute for every 10 hp (one liter per minute for every 2 kW). The thermal ratings listed are based upon a 50°F (28°C) temperature rise between the inlet and outlet. The outlet water temperature should not exceed 150°F (65°C). Maximum water jacket inlet pressure is 45 psi (3.1 bar) for the 18"/24" and 40 psi (2.8 bar) for the 36".
Contact WPT Engineering for Ethylene Glycol Flow requirements.
J
AIR INLETS (PER ACTUATOR)
K
L
MOUNTING HOLES (EQUALLY SPACED)
M
N
BORE RANGE
SIZE
SIZE (NPT)
HOLE CENTER
QTY
SIZE
BOLT CIRCLE
QTY
SIZE
BOLT CIRCLE
SIZE (NPT)
MIN
MAX2
1/2-14
14.188 (360.36)
30°
12
21/32 (16.7)
22.000 (558.8)
3
3/8-16
9.125 (231.78)
1/2-14
2 1/4 (57.2)
5 11/32 (135.7)
118
1/2-14
14.188 (360.36)
30°
12
21/32 (16.7)
22.000 (558.8)
3
3/8-16
9.125 (231.78)
1/2-14
2 1/4 (57.2)
5 11/32 (135.7)
218
1/2-14
14.188 (360.36)
30°
12
21/32 (16.7)
22.000 (558.8)
3
3/8-16
9.125 (231.78)
1/2-14
2 1/4 (57.2)
5 11/32 (135.7)
318
1/2-14
14.188 (360.36)
30°
12
21/32 (16.7)
22.000 (558.8)
3
3/8-16
9.125 (231.78)
1/2-14
2 1/4 (57.2)
5 11/32 (135.7)
418
1/2-14
21.000 (533.40)
24°
12
21/32 (16.7)
28.750 (730.25)
6
3/8-16
12.250 (311.15)
3/4-14
2 3/4 (69.9)
7
(177.8)
124
1/2-14
21.000 (533.40)
24°
12
21/32 (16.7)
28.750 (730.25)
6
3/8-16
12.250 (311.15)
3/4-14
2 3/4 (69.9)
7
(177.8)
224
1/2-14
21.000 (533.40)
24°
12
21/32 (16.7)
28.750 (730.25)
6
3/8-16
12.250 (311.15)
3/4-14
2 3/4 (69.9)
7
(177.8)
324
1/2-14
21.000 (533.40)
24°
12
21/32 (16.7)
28.750 (730.25)
6
3/8-16
12.250 (311.15)
3/4-14
2 3/4 (69.9)
7
(177.8)
424
1/2-14
28.000 (711.20)
20°
16
1 1/16 (27.0)
42.000 (1066.80)
6
1/2-13
17.500 (444.50)
1-1/4-11 1/2
4
(101.6)
10 1/8 (257.2)
136
1/2-14
28.000 (711.20)
20°
16
1 1/16 (27.0)
42.000 (1066.80)
6
1/2-13
17.500 (444.50)
1-1/4-11 1/2
4
(101.6)
10 1/8 (257.2)
236
1/2-14
28.000 (711.20)
20°
16
1 1/16 (27.0)
42.000 (1066.80)
6
1/2-13
17.500 (444.50)
1-1/4-11 1/2
4
(101.6)
10 1/8 (257.2)
336
1/2-14
28.000 (711.20)
20°
16
1 1/16 (27.0)
42.000 (1066.80)
6
1/2-13
17.500 (444.50)
1-1/4-11 1/2
4
(101.6)
10 1/8 (257.2)
436
1/2-14
28.000 (711.20)
20°
16
1 1/16 (27.0)
42.000 (1066.80)
6
1/2-13
17.500 (444.50)
1-1/4-11 1/2
4
(101.6)
10 1/8 (257.2)
536
NOTES:
1 36" brakes: +0.000/-0.005 (+0.00/-0.13)
2 Maximum bores shown are with a standard square key. Contact WPT Engineering for bore sizes exceeding those shown.
Contact Customer Service for drawing before finalizing design. Certified prints available on request.
Dimensions are considered as reference only and subject to change.

pageCatalog pdf di En 2012-06-22-01