DRYMAX ER60 Segmented Wheel Dryer
The DRYMAXER60 segmented wheel dryer combines both the advantages ofa twin bed desiccant dryer with those ofa desiccant wheel dryer. The DRYMAXER60 offers a constant low dew point, extremely energy efficient operation and the easy exchange ofdesiccant without costly wheel replacement.
— Ambient Independent Dew Point to -40°C (-40°F)
— ThermalEnergyReturn
The thermal energy ofthe drying process exhaust air is recovered to reduce the total energy required. Thus, the dryer constantly saves energy during the drying process.
— SmartWheel
The regeneration temperature and revolution speed ofthe wheel are automatically adjusted to achieve the freely selectable constant dew point (dew point sensor optional) and thus, reduces energy consumption.
— Material Protection Function
Avoids over-drying and thermal degradation ofthe plastic resin by short term lowering ofthe drying temperature during production stoppages ofthe processing machine.
— Micro Particle Filter in ReturnAir
5
1 \
\
Regeneration blower Process air blower Regeneration heater Heatexchanger Inlet filter Return airfilter Regeneration phase Cooling phase Process phase
Segmented
7
DRYMAX ER60 Options
DewPointSensor
The integrated dew point display with alarm function offers energy savings as the dew point reading can be used to delay switchover ofthe bed until a user defined dew point level is reached.
ReturnAirCooler
Highest efficiency is directly integrated into the filter housing and retrofittable without tools.
Micro Particle Filterin ProcessAir
Dust separation efficiency of up to 99.9% for high process safety of materials with optical quality (on DRYMAXD60 and 100).
High Temperature Construction
Increased processtemperaturefromastandard 130°Cto 180°Cforthe efficient drying ofmaterials requiring higherdrying temperatures.
AlarmLightandHorn
Increased operating safety in error situations.