| | | | | | | | | | | o o | 100-H | 100 100 100 150 | | | | 100 | 100 | | | | 57 | 57 | | | | 120 | 120 | | | | 71 | 71 | | | | - | 4 | 4 | | | | - | in Dryer | atHopper | | | | | | | | | | |
| | | RYMAX | | Tr?S"S"5^^^0 2 § 2 § S o < o < o < o < o < "7 2 £ 0S O25 Or*> 0>= 0>= ° = ^3 g o 0 oo oo oo oo oo o^S 8^5 8\5 8\5 o£ 2S 2^ £ °> § *~2 '— *"£ ""2 ""2 1-0 *o 2 in 2 2 §^ ou ou ou ^ I- I- »~ Q_ Q_ Q_ Q_ Q_ | | |
| | | |
| | | |
| | | Processair[mVh] @50 Hz Process air [cfm] @ 50 Hz Processair[mVh] @60 Hz Process air [cfm] @ 60 Hz Process heater [kW] Process heater Regen. heater [kW] Power supply EU/US [amps] Power plug EU/US Drying hoppersize [cu.ft] with casters IMM loaders IMM conveying volume Hopper loaders Hopper conveying volume | | |
| | | 100 57 120 71 4 amSilo 2 11.6/10 | | 100 57 120 71 4 in Dryer 2 17.4/14.9 70/70 2.47/2.47 at Dryer yes | | 100 57 120 71 4 in Dryer 2 17.4/14.9 CEE32/without | | 100 57 120 71 4 in Dryer 2 17.4/14.9 150/100 5.3/3.53 at Dryer yes | | 100 57 120 71 4 atHopper 2 17.4/12.5 CEE 16/without | | |
| | | |
| | | 2 2 | | |
| | | |
| | | 5.8/5.3 11.6/10 | | 11.6/10 CEE16/w
| | |
| | | | |
| | | | | |
| | | | | | | | | | | | | 150 | 100 | 150 | 200 | 300 | | | | 5.3 | 3.53 | 5.3 | 7.06 | 10.59 | | | | | | | | | | | | | | | | | | | | | | 150 | 200 | 300 | 400 | | | | 5.3 | 7.06 | 10.59 | 14.13 | | | | | | | | | | | |
| | | 100 3.53 | | | 400 14.13 | | | 100/70 3.53/2.47 | | 100/100 3.53/3.53 | | 150/70 5.3/2.47 | | | 150/150 5.3/5.3 | | 100 3.53 | | |
| | | | | |
| | | | |
| | | | |
| | | on IMM yes | | at Dryer yes | | | at Dryer yes | | |
| | | yes | | |
| | | |
| | | uptol.5 l/cycle | | |
| | | |
| | | 6 l/cycle | 12 l/cycle | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | DRYMAX | ED ED | ED | ED | ED | ED | ED | ED | ED | ED80 | ED | | | | | 80 80 | 80 | 80 | 80 | 80 | 80 | 80 | 80 | 30 | 80 | | | | | HI | 70 | 100 | 150 | 70 | 100 | 150 | 200 | 0 | 400 | | | | | | | | | M | M | M | M | M | M | | | | Frocessair[m3/h]@50Hz | 80 | 80 | 80 | | | | | | | | | | | | | | | | | | |
| | | (-> 7r o o o o o LU O LU LU LU LU LU | | |
| | | |
| | | 80 47 96 57 3 3 2 2 | | 80 47 96 57 3 2 atHopper 22.2/18.8 150/100 53/3.53 | | 80 47 96 57 3 2 atHopper 14.6/12.7 CEE 16/without | | |
| | | |
| | | Froce5sair[dm]@50Hz FrocB5sair[m3/h]@60Hz Roeessair[dhi]®60Hz ProcessheatertkW] Processheater_ Regen.heater[kW] R^suppl.EU/US[amps] PowerplugEU/US | | |
| | | 47 96 57 | | 47 96 57 | | 47 96 57 | | |
| | | |
| | | 2 2 | | 2 | | |
| | | |
| | | |
| | | in Dryer 12.2/10.4 | | in Dryer 12.2/10.4 | | in Dryer 12.2/10.4 | | |
| | | atHopper 22.2/18.8 | | atHopper 22.2/18.8 | | |
| | | |
| | | CEE 16/without | | CEE32/without | | |
| | | | |
| | | | | | | | | | | | | | | | | | Dryinghoppersize[ltr.] | - | 70 | 100 | 150 | 70 | 100 | 150 | 200 | 300 | | | | Dryinghoppersize[cu.ft] | - | 2.47 | 353 | 53 | 2.47 | 3.53 | 5.3 | 7.06 | 1059 | | | | | - | on IMM | | | at Dryer | | | | | withcasters | - | | yes | | | | yes | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | 100 | 150 | 200 | 300 | 400 | | | | 3.53 | 5.3 | 7.06 | 10.59 | 1412 | | | | | | | | | | | | |
| | | 400 14.12 | | 70/70 2.47/2.47 | | 100/70 3.53/2.47 | | 100/100 3.53/353 | | 150/70 53/2.47 | | | 150/150 53/5.3 | | |
| | | |
| | | |
| | | |
| | | at Dryer yes | | at Dryer yes 1 uptol.5 l/cycle 1 6 l/cycle 12 l/cycle | | |
| | | |
| | | |
| | | IMMIoaders | | |
| | | |
| | | IMMconveyingvolume Hopperloaders_ Hopperconveyingvolume | | |
| | | |
| | | 70 100 150 200 300 400 PDC/ PDC/ PDC/ PDC/ PDC/ PDC/ (DUAL) (DUAL) (DUAL) (DUAL) (DUAL) (DUAL) | | |
| | | |
| | | Processair[mVh] @50 Hz Process air [cfm] @ 50 Hz Processair[mVh] @60 Hz Process air [cfm] @ 60 Hz Process heater [kW] Process heater Regen. heater [kW] Power plug EU/US Drying hopper size [Itr.] Drying hopper size [cu.ft] Drying hopper with casters IMM loaders IMM conveying volume Hopper loaders Hopper conveying volume | | |
| | | 60 35 72 42 -3 ext. | | 60 35 72 42 3 atHopper | | 60 35 72 42 3 atHopper 2 | | 60 35 72 42 3 atHopper 2 CEE 16/without 70 100 150 200 300 400 2.47 3.53 5.30 7.06 10.59 14.12 | | |
| | | |
| | | |
| | | 2 2 | | |
| | | |
| | | CEE 16/without
| | |
| | | |
| | | | | | | | | | | | 100 | 150 | 200 | 300 | | | | 3.53 | 5.30 | 7.06 | 10.59 | | | | | | | | | | | |
| | | 70 2.47 | | 100 3.53 | | 70 2.47 | | | 400 14.12 | | |
| | | | |
| | | |
| | | on IMM yes | | at Dryer yes PDC 1/ DUAL 2 upto5 l/cycle -1 6 l/cycle | | |
| | | yes | | |
| | | |
| | | |
| | | 13 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |