METALYNX2 Designed to improve efficiency in the construction industry Flexibility is key
Open the catalog to page 1METALYNX2Flexibility for the future Structured wiring with METALYNX2 METALYNX2 is designed to fulfil the needs of all building installations A comprehensive range of products offer fast and failsafe installation using a unique coding system for power distribution, HVAC, Underfloor and complete integration to lighting controls using DALI, KNX or LON based systems. The system offers cost and program savings with maximum flexibility for the future, this makes the METALYNX2 system ideal for many applications.
Open the catalog to page 232 A rated Turned and milled contacts for optimal load performance Under floor applications High load applications Compact ■■ 38 mm diameter circular design ■■ Compact and easy handling ■■ Cost savings for installation routes through fire barriers and stud work walls Effective ■■ Cost savings in comparison to traditional methods ■■ Time savings on installation and program times Smart ■■ Cable termination with crimp technology ■■ non-m
Open the catalog to page 4The system makes the difference METALYNX2 Highlights Sustainable ■■ Cost certainty with structured pre-wired, pre-tested system ■■ Environmentally friendly with zero wastage on site Flexible ■■ Flexibility with the design of projects ■■ Future proof allowing changes and reconfiguration ■■ Numerous codings to ensure mis-match of applications impossible ■■ Factory tested and manufactured products to the highest standards ■■ METALYNX 2 meets all relevant European IEC and British Standards ■■ IEC
Open the catalog to page 5METALYNX2 Specification Needs for a structured wiring system A prefabricated wiring system shall be utilised for the distribution of lighting, and power circuits. The system shall offer a high degree of flexibility and comprise modular sub circuit distribution, which is entirely prefabricated off site. The system will provide a complete installation from the respective distribution board to the furthest point of a circuit. ■■ The wiring components for lighting and power systems shall be colour coded and polarised in such a way that one system shall not plug into the components of the other...
Open the catalog to page 6System Components Home Run Home run cables comprising of 2.5 mm2, 4.0 mm2 or 6.0 mm2 LSOH singles (number dependant on number of circuits) in metal flexible conduit (up to 40 mm diameter) complete with gland and lock-nut. If the structured wiring system is to be integrated with lighting or BMS control system the home run cable will generally comprise of a Belden type 8719 fieldbus cable or DALI control pairs. These are to be run internally of the conduit with the power conductors, not separately. Length of the Home Run cable will be determined by position on site. This cable can be supplied...
Open the catalog to page 7■■ High Level Lighting & Power Systems ■■ Underfloor Systems ■■ Building Control Systems ■■ Home Run ■■ Master Distribution Box (MDB) ■■ Extender Cable ■■ Fused Spur Unit ■■ T Connector ■■ Switch Module System Benefits ■■ Flexibility with the design of projects ■■ Cost savings in comparison to traditional methods ■■ Significant time savings on installation and program times ■■ Future proof system allowing changes and reconfiguration ■■ Structured pre-wired, pre-tested system for cost certainty ■■ Zero wastage on site ■■ METALYNX 2 meets all the relevant European IEC and British Standards ■■...
Open the catalog to page 9METALYNX2 Installation Installation Guide 1 Fix the master distribution box into position, as indicated on the installation drawing supplied. Then clip the Home Run back to the Distribution Board for termination. Attach the Lighting Control Module (LCM) to the ceiling or soffit, in the position shown on the installation drawing supplied. Fit the METALYNX 2 structured wiring T-connector to the LCM. Depending on the LCM manufacturer, this may be a plug-in connection or may require a screw termination. Most LCMs are pre-wired at the factory so that all connections on site are pluggable to save...
Open the catalog to page 10METALYNX2 Support & Service Design, develop & deliver Using Wieland prefabricated wiring system you will receive a fully engineered solution including working CAD drawings, project management and on site support where required. Deliveries are arranged to meet your programme needs. The product is easy and fast to install with limited number of line items to ensure simplicity. It will reduce on-site labour needs and reduce programme times. We estimate a labour saving of 70% in comparison to traditional methods in this area, with the added benefits of improved cost certainty. The system is...
Open the catalog to page 11Starter Lead Cables female - free end Cable LSOH as per BS7211 and Belden 8491 when Coding C8 LON
Open the catalog to page 12Extender Lead Connecting cables male - female Cable LSOH as per BS7211 and Belden 8491 when Coding C8 LON
Open the catalog to page 13Drop Lead Connecting male - free end Cable LSOH as per BS7211 and Belden 8491 when Coding C8 LON
Open the catalog to page 14Components Cable LSOH as per BS7211 and Belden 8491 when Coding C8 LON Coding C5 Dimming or DALI T Connector - Conduit Drop Coding C3 T Connector - SPUR (tap off fused with 10 A*) Coding C1 Switch Module CodingPart No. 1 x C7/IN, 3x C7/OUT (distributor) G5.800.0023.7 Note: different size fuses can be purchased separately
Open the catalog to page 15gesis® Industrial technology Wieland Electric Ltd. Riverside Business Center Walnut Tree Close Guildford /Surrey GU1 4UG Phone +44 1483 531213 Fax +44 1483 505029 sales.uk@wieland-electric.com www.wieland.co.uk www.wielandmetalynx.co.uk Solutions for the control cabinet • DIN rail terminal blocks – Screw, tension spring or push-in connection technology – Wire cross sections up to 300 mm2 – Numerous special functions – Software solutions interfacing to CAE systems • Safety – Safe signal acquisition – Safety switching devices – Modular safety modules – Compact safety controllers –...
Open the catalog to page 16All WIELAND ELECTRIC catalogs and technical brochures
-
RST® Catalog
268 Pages
-
RST®MICRO MICRO CONNECTION
12 Pages
-
DIN RAIL TERMINAL BLOCKS
176 Pages
-
samos®PRO COMPACT
12 Pages
-
podis®5G6 POWER DISTRIBUTION
2 Pages
-
podis®HELLO CHARGING
4 Pages
-
wieplan
2 Pages
-
HELLO WIND
20 Pages
-
Full speed ahead
16 Pages
-
samos®pro
2 Pages
-
selos+fasis
188 Pages
-
sensor pro
8 Pages
-
HELLO LIGHT
32 Pages
-
Modular flexibility
12 Pages
-
PCB connector 8105 B
2 Pages
-
revos mini Q5
2 Pages
-
revos E-2000
16 Pages
-
Revos docking
2 Pages
-
wiecon
2 Pages
-
revos basic
2 Pages
-
Installation Column
16 Pages
-
Machine building
24 Pages
-
PCB Terminals - Catalog
144 Pages
-
Metalynx² - Brochure
16 Pages
-
smart Installation - Brochure
24 Pages
-
gesis® FLEX - Brochure
12 Pages
-
wienet VPN router
12 Pages
-
Terminal Block Catalog
160 Pages
-
safety - Catalogue 2015
118 Pages
-
gesis® indoor - Catalog 2015
288 Pages
-
Machine building - Brochure
24 Pages
-
gesis® RST® - Catalog 2015
228 Pages
-
gesis® ELECTRONIC
84 Pages
-
Interface Catalog 2012
108 Pages
-
Wieland product range
40 Pages
-
safety sensors
112 Pages
-
Safety products
10 Pages
-
PCB Terminals
126 Pages
-
wietap - Overvoltage Protection
12 Pages
-
wipos - Power Supply Units
4 Pages
-
Timers
20 Pages
Archived catalogs
-
AT Catalog 2006 Page 0290-0327
38 Pages