AT Catalog 2006 Page 0482-0526 (Field Bus Components)
45Pages

{{requestButtons}}

Catalog excerpts

AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 2

ricos ricos TP Fieldbus Components 483

Open the catalog to page 2
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 3

484 rriciocs os Fieldbus components Contents

Open the catalog to page 3
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 4

Subject to change without further notice 485 ricos Fieldbus components Contents ricos Remote I/O (IP 20) 487 ricos TP Remote I/O for extended requirements (IP 20) 529 Contents – Fieldbus components Page

Open the catalog to page 4
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 6

ricos Fieldbus Components 487

Open the catalog to page 6
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 7

Selection by function General information Technical information on bus systems Operating and display functions Modular system Bus coupler Profibus DP CANopen DeviceNet Interbus Ethernet PLC Ethernet I/O modules binary I/O Interface Counter module Positioning module Analog I/O 488 Subject to change without further notice rriciocs os Remote I/O Contents 490 492 493 496 ricos BC-DP 499 ricos EC-DP 504 ricos BC-CANopen 500 ricos EC-CANopen 505 ricos BC-CAN-DN 500 ricos EC-CAN-DN 505 ricos BC-S 499 ricos EC-S 504 ricos BC-Ethernet 501 ricos BC-Ethernet PLC 502 8 I/O for 24 V DC ricos 8 I/O 507 8...

Open the catalog to page 7
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 8

Compact modules Profibus DP CANopen DeviceNet Interbus Subject to change without further notice 489 ricos Remote I/O Contents 8 I/O for 24 V DC ricos COM-DP 8I/O 524 8 I and 8 I/O for 24 V DC ricos COM-DP 8I 8I/O 524 16 I for 24 V DC ricos COM-DP 16 I 524 16 O for 24 V DC ricos COM-DP16 524 8 I/O for 24 V DC ricos COM-CO 8I/O 525 8 I and 8 I/O for 24 V DC ricos COM-CO 8I 8I/O 525 16 I for 24 V DC ricos COM-CO 16 I 525 16 O for 24 V DC ricos COM-CO 16 O 525 8 I/O for 24 V DC ricos COM-DN 8I/O 525 8 I and 8 I/O for 24 V DC ricos COM-DN 8I 8I/O 525 16 I for 24 V DC ricos COM-DN 16 I 525 16 O...

Open the catalog to page 8
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 9

490 Subject to change without further notice rriciocs os Remote I/O Selection per function CATALOG PAGE FUNCTION FIELDBUS Profibus DP CANopen Interbus DeviceNet Ethernet Modbus TCP/IP PLC (openly programmable) Ethernet TCP/IP DIGITAL INPUTS AND 24 V DC input OUTPUTS 115 V AC input 230 V AC input 24 V DC 1 A output 24 V DC 2 A output 24 V DC 1 A neg. output Relay output ANALOG INPUTS AND Pt 100 / 1000 OUTPUTS Thermocouple J/K/T Voltage input 0...10 V Voltage input +/ - 10 V Voltage output 0...10 V Voltage output +/ - 10 V Current input 0...20 mA Current input 4...20 mA Current output 0...20...

Open the catalog to page 9
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 10

Subject to change without further notice 491 ricos ricos BC-DP ricos BC-CANopen ricos BC-S ricos BC-DEVICENET ricos BC-Ethernet ricos BC-Ethernet PLC ricos EC-DP ricos EC-CANopen ricos EC-S ricos EC-DEVICENET ricos 8I/O ricos 8I 8I/OI ricos 16I ricos 4I AC 115 V ricos 4I AC 230 V ricos 16O ricos 8O DC 2A ricos 8O NEG ricos 4O RELAY ricos COUNTER ricos POSITION ricos RS 232 / RS 485 ricos 4AI Pt100 ricos 4AI TC ricos 4AI/0...10 V ricos 4AI/+-10 V ricos 4AI4AO/0...10 V ricos 4AI4AO/+-10 V ricos 4AI/0-20 mA ricos 4AI/4-20 mA ricos 4AI4AO/0-20 mA ricos 4AI4AO/4-20 mA ricos COM-DP 8I/O ricos...

Open the catalog to page 10
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 11

rriciocs os 492 Subject to change without further notice Remote I/O General information A field bus system introduces a high level of performance when compared to conventional wiring technology. The possibility for intelligent and convenient distribution of signals is a significant benefit of digital fieldbus technology. Nowadays, there are a variety of functional and topological variants available on the market. This broad spectrum is due to the various requirements of the individual branches of industry as well as the interests of the manufacturer’s company or international standards. As...

Open the catalog to page 11
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 12

ricos Subject to change without further notice 493 Remote I/O Technical information on bus systems PROFIBUS (process fieldbus) has a number of variations including PROFIBUSDP which is established in DIN 19245, section 3 and integrated in the European fieldbus standard EN 50170, PROFIBUS has an optimum transmission rate for opening up the object-related system area as well as the sophisticated sensor/actuator area. It is tailor-made to the requirements for fast, efficient data exchange between the programmable controllers and the distributed devices such as digital or analog input/output...

Open the catalog to page 12
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 13

rriciocs os 494 Subject to change without further notice Remote I/O Technical information on bus systems In 1983, the auto industry formulated its requirement for a bus system for use in motor vehicles. An electrical two-wire bus should replace the extensive cable harnesses for the connection of electrical systems. This was also urgently needed as the traditional cable harnesses in vehicles already exceeded 2 km in length and a mass of over 100 kg. However, requirements arose which could not be met by the bus systems that were available at that time. These were in particular: High level of...

Open the catalog to page 13
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 14

ricos Subject to change without further notice 495 Remote I/O Technical information on bus systems The INTERBUS was specially developed by Phoenix Contact for use in machine systems and rapid processes. This fieldbus system is therefore primarily used in production automation at system level and as an object-related fieldbus for the connection of sophisticated sensors and actuators. It can be used in standard PLC applications and industrial PCs with relatively little cost and effort. The INTERBUS has been structured using point-to-point connection as an active, coupled ring. Each bus device...

Open the catalog to page 14
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 15

rriciocs os 496 Subject to change without further notice Remote I/O Operating and display functions The outputs are switched off and the inputs are no longer available. in STOP mode Analog and digital I/O channels can be ‘frozen’ at a fixed switching state to simulate parts of the system. in LOCK mode The last 20 process images of the nodes can be recorded and displayed. in TRIGGER mode Digital and analog I/O channels can be operated manually without the fieldbus (offline) in FORCE mode STOP LOCK TRIGGER FORCE

Open the catalog to page 15
AT Catalog 2006 Page 0482-0526 (Field Bus Components) - 17

Makrolon 2805, Lexan 161R, Polyamide 6.0 GF20 black according to DIN VDE 0304 T3 (IEC 707) and UL 94-V-2 according to DIN VDE 0303 T1/06.84 CTI = 600 according to DIN VDE 0304 20,000 h/5,000 h 100/115 °C according to DIN VDE 0303 T2 (DIN 53481/>15 kV/mm) Class I according to IEC 536 IP20 according to EN 60529 falling height 1 m (DIN IEC 68-2-32), in packaging according to IEC 68 part 2, see ”free fall“ test 10...95%, no condensation 860...1060 hPa 10 mm 2.4 x 1.5 mm according to IEC 999 TS35 approx. 190 g rriciocs os 498 Subject to change without further notice Remote I/O Bus couplers,...

Open the catalog to page 17

All WIELAND ELECTRIC catalogs and technical brochures

  1. RST® Catalog

    268 Pages

  2. wieplan

    2 Pages

  3. HELLO WIND

    20 Pages

  4. samos®pro

    2 Pages

  5. selos+fasis

    188 Pages

  6. sensor pro

    8 Pages

  7. HELLO LIGHT

    32 Pages

  8. revos E-2000

    16 Pages

  9. METALYNX2

    16 Pages

  10. wiecon

    2 Pages

  11. revos basic

    2 Pages

  12. safety sensors

    112 Pages

  13. PCB Terminals

    126 Pages

  14. Timers

    20 Pages

Archived catalogs