Open the catalog to page 1TLI Application Area: Resolution: Min. Mounting Length: Max. Mounting Length: Transmitters of the series XM-800E (XT-800E) provide reliable measurement and control for liquid levels. Additionally they can be used as position sensors for vertical displacements. The transmitters are built according to user-specific requirements. They have proved successful in a wide range of different industrial applications as well as in many special applications. Transmitter Series XM-800E (XT-800E) Industry, Chemical Industry 5 +/- 2 mm 400 mm 3000 mm Depending on liquid level or displacement a magnet...
Open the catalog to page 2Flange DN65/PN16 EN1092-1 * • BCCC 316/316L • BM brass • Other flanges on request. Min. DN65 od. 2 1/2" ANSI Tank screw fixing 1" • TC 1 316/316L • TM 1 brass Inside screw fixing 1/2" • EC 1/2 316/316L • EM 1/2 brass Bulkhead fitting • AC 316/316L • AM brass Inside screw fixing 1" • EC 1 316/316L • EM 1 brass Tank screw fixing 2"* • TC 2 316/316L • TM 2 brass Type Material Max. pressure Operating temp. Minimum density of the liquid Immersion depth at density = 1 g/cm3 * Versions with protection tube (damping tube) on request Tli E/09.2013 Modifications reserved
Open the catalog to page 3Electrical connection XM-800E (3-wire) • S Plug connector ca.48 Pg11 Ø 7...12mm Brass; Nickel plated SW21 Pg13,5 Ø 7...12mm Brass; Nickel plated SW21 Pg13,5 Ø 7...12mm Brass; Nickel plated SW21 Note Because of the internal wiring of the transmitter, the output voltage and not the transmitter resistance has to be measured when a test is taken. Transmitter Messwertgeber Wiring diagram XT-800E with current signal Wiring diagram XM-800E with voltage signal Function Operation of the transmitter in connection with signal processing units; In this mode of operation voltage supply is provided by...
Open the catalog to page 4Order data Type code: X...-800E-...-...-...-... Electrical connection •S Plug connector • K6 Junction box • K11 Junction box • P-PVC PVC cable, with cable gland (Standardlength 3m) • P-Si Si cable, halogen free, with cable gland (Standardlength 3m) Mounting element • BCCC Flange 316/316L • BM Flange brass • Other flanges on request • TC 1 Tank screw fixing 316/316L • TM 1 Tank screw fixing brass • TC 2 Tank screw fixing 316/316L • TM 2 Tank screw fixing brass • EC 1/2 Inside screw fixing 316/316L • EM 1/2 Inside screw fixing brass • EC 1 Inside screw fixing 316/316L • EM 1 Inside screw...
Open the catalog to page 5TLI Application Area: Resolution: Min. Mounting Length: Max. Mounting Length: Industry, Chemical Industry 2.5 +/- 1 mm 200 mm 1500 mm Transmitters of the series XM-825E (XT-825E) provide reliable measurement and control for liquid levels. These are developed from the XM800E (XT-800E) series with double resolution and a well-tried mechanism. Additionally they can be used as position sensors for vertical displacements. The transmitters are built according to user-specific requirements. They have proved successful in a wide range of different industrial applications as well as in many special...
Open the catalog to page 6Flange DN65/PN16 EN1092-1 * • BCCC 316/316L • BM brass • other flanges on request Min. DN65 od. 2 1/2" ANSI Tank screw fixing 1" • TC 1 316/316L • TM 1 brass Inside screw fixing 1/2" • EC 1/2 316/316L • EM 1/2 brass Bulkhead fitting • AC 316/316L • AM brass Inside screw fixing 1" • EC 1 316/316L • EM 1 brass Tank screw fixing 2" * • TC 2 316/316L • TM 2 brass Type Material Max. pressure Operating temp. Minimum density of 0.85 g/cm3 the liquid Immersion depth at 35 +/- 2mm density = 1 g/cm3 * Versions with protection tube (damping tube) on request Tli E/09.2013 Modifications reserved
Open the catalog to page 7Electrical connection XM-825E (3-wire) • S Plug connector ca.48 Pg11 Ø 7...12mm Brass; Nickel plated SW21 Ø 7...12mm Pg13,5 Brass; Nickel plated SW21 Ø 7...12mm Pg13,5 Brass; Nickel plated SW21 Note Because of the internal wiring of the transmitter, the output voltage and not the transmitter resistance has to be measured when a test is taken. Transmitter Messwertgeber Wiring diagram XT-825E with current signal Wiring diagram XM-825E with voltage signal Function Operation of the transmitter in connection with signal processing units; In this mode of operation voltage supply is provided by...
Open the catalog to page 8Order data Type code: X...-825E-...-...-...-... Electrical connection •S Plug connector • K6 Junction box • K11 Junction box • P-PVC PVC cable, with cable gland (Standardlength 3m) • P-Si Si cable, halogen free, with cable gland (Standardlength 3m) 316/316L 316/316L Buna N Buna N Titanium Mounting element • BCCC Flange 316/316L • BM Flange brass • other flanges on request • TC 1 Tank screw fixing 316/316L • TM 1 Tank screw fixing brass • TC 2 Tank screw fixing 316/316L • TM 2 Tank screw fixing brass • EC 1/2 Inside screw fixing 316/316L • EM 1/2 Inside screw fixing brass • EC 1 Inside screw...
Open the catalog to page 9Transmitter Series XM-800E-PVDF (Transmitter Series XT-800E-PVDF) TLI Application Area: Resolution: Min. Mounting Length: Max. Mounting Length: Industry, Chemical Industry 5 +/- 2 mm 400 mm 3000 mm Transmitters of the series XM-800E-PVDF (XT-800EPVDF) provide reliable measurement and control for liquid levels. Additionally they can be used as position sensors for vertical displacements. The transmitters are built according to user-specific requirements. They have proved successful in a wide range of different industrial applications as well as in many special applications. The PVDF series...
Open the catalog to page 10Material PVDF Immersion depth at density = Modifications reserved WEKA AG - Schiirlistrasse 8 - CH-8344 Baretswil www.weka-ag.ch ; info@weka-ag.ch
Open the catalog to page 11All WEKA catalogs and technical brochures
-
Control and shut-off valves
8 Pages
-
Level Measurement
8 Pages
-
Transmitter Series XT-800R
4 Pages
-
Top of Tank Line SS & Plastik
15 Pages
-
Visual Level Indicator VLI
8 Pages
-
Visual Level Indicator CuNi
2 Pages
-
Tank Level Instruments TLI
6 Pages
-
Heat Tracing 20060307 70-80
1 Pages
Archived catalogs
-
Transmitter Series XT-800R
4 Pages
-
VLI
8 Pages
-
Weka flyer tli
6 Pages
-
WEKA flyer
4 Pages
-
Sterilization
2 Pages
-
Textile Dyeing
2 Pages
-
Petrochemical Industry
3 Pages
-
Refrigeration
2 Pages