video corpo

Weishaupt gas burners type G Dual fuel burner gas/oil types GL and RGL Sizes 5 to 11 - 24 Pages

  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

  10. P. 10

  11. P. 20

Catalogue excerpts

Weishaupt gas burners type G Dual fuel burner gas/oil types GL and RGL Sizes 5 to 11 1/2002 GB

 Open the catalogue to page 1

Weishaupt gas and dual fuel burners ments for operational safety, easy installation, and reliability. They operate economically and envi- ronmentally friendly. The oil side of the dual fuel burners comply with of dual fuel burners comply with type tested. The burners distinguish themselves through a variety of interesting features. ■ Large capacity and range of ■ Automatic sequence of operations ■ Combustion chamber pre-purge ■ Safe flame monitoring ■ Stable fan characteristics - good combustion results ■ Hinged burner casing ■ Simple installation, adjustment and servicing as components are easily ■...

 Open the catalogue to page 2

Gas burner G, sliding two stage (ZM) or modulating (M) Gas burner G, with inbuilt controls Gas burner G, sliding two stage (Z) Electromagnetic coupling Dual fuel burner GL, sliding two stage (ZM) or modulating (M) 3

 Open the catalogue to page 3

Hinged flange with easily serviced combustion head Adjustable flame tube for adapting to heating appliance 4 Regulating drive dual fuel burner GL: gas side sliding two stage (ZM), oil side two stage Regulating drive dual fuel burner RGL: gas and oil side sliding two stage ZM

 Open the catalogue to page 4

Type survey CE and DIN DVGW registration numbers and type test numbers Weishaupt gas and dual fuel burners rapid burner capacity control Dual fuel slow burner capacity control Dual fuel burner Servomotor with Servomotor with Servomotor with Servomotor with appliances requiring rapid response) Gas: slid, two stage Gas: slid, two stage Gas: modulating Oil: two stage Oil: three stage Oil: two stage Servomotor with Servomotor with Servomotor with Servomotor with Servomotor with Servomotor with Explanation of type designation capacity range Electricity supply (servomotor with 8 sees, run time) servomotor...

 Open the catalogue to page 5

■ Gas is released for starting by opening the solenoid valve DMV. The gas butterfly releases ■ Release of the partial and full load gas quantity by the gas butterfly being opened by the servo- sliding two stage (ZM) and modulating (M) ■ Gas is released for starting by opening the solenoid valve DMV. The gas butterfly releases Burner sizes 8 to 11 have an additional valve for ignition gas. On start the solenoid valve for ignition gas opens. After 1 0 seconds the main gas solenoid valve opens and the ignition gas solenoid valve closes again. ■ The burner capacity is controlled between partial and...

 Open the catalogue to page 6

Included in burner delivery Available versions Burner type G5-G8Z G5-G11ZM GL5-GL8Z GL5-GL9ZM GL8-GL9TM RGL5-RGL11 Burner casing, hinged flange, sight glass cover, Weishaupt burner motor, air control casting, fan, air pressure switch, servomotor, gas/air compound regulation with regulating cam, combustion head, ignition transformer, ignition cable, ignition electrodes, terminal strip, flange gasket, fixing screws ● ● ● ● ● Interlock switch on hinged flange ● ● ● ● ● Burner control with flame sensor (ionisation electrode) loose for fitting into control panel ● ● ● ● ● ● ● ● ● ● Burner control with...

 Open the catalogue to page 7

Burner selection gas burners Burner capacity / combustion chamber resistance The gas capacity graphs are in accordance with EN 676 and relate to an installation elevation of 500 m. There is a ratings reduction of approx. 1 % per 100 m on installations with an elevation above 500 m. Gas burners - operation with towns gas or sewage gas When selecting burners, the given burner ratings within the range of the resistance graphs must be reduced by 10% for towns gas Gas burners version LN (NOx reduced) Stringent guidelines and limit values of various emission laws can be adhered to by using the gas burners...

 Open the catalogue to page 8

Burner type Type of combustion head Burner type Type of combustion head

 Open the catalogue to page 9

Burner selection gas burners Burner capacity / combustion chamber resistance The gas capacity graphs are in accordance with EN 676 and relate to an installation elevation of 500 m. There is a ratings reduction of approx. 1 % per 100 m on installations with an elevation above 500 m. Gas burners - operation with towns gas or sewage gas When selecting burners, the given burner ratings within the range of the resistance graphs must be reduced by 10% for towns gas Gas burners version LN (NOx reduced) Stringent guidelines and limit values of various emission laws can be adhered to by using the gas burners...

 Open the catalogue to page 10

Burner type Type of combustion head Burner type Type of combustion head

 Open the catalogue to page 11

Selection of valve trains with double solenoid valves (DMV) Rating Low pressure supply (gas pressure kW in mbar into isolating valve, Pemax = 300 mbar) Nominal diameter of valve trains Nominal diameter of gas butterfly valve High pressure supply (setting pressure in mbar into double solenoid valve) Nominal diameter of valve trains Nominal diameter of gas butterfly valve The combustion chamber pressure in mbar must be added to the minimum gas pressure For selection of valve trains for towns gas see separate work sheet Print No. 900. Pressure regulators to Dl N 3380 with safety diaphragm are used...

 Open the catalogue to page 12

Rating Low pressure supply (gas pressure kW in mbar into isolating valve, Pemax = 300 mbar) Nominal diameter of valve trains Nominal diameter of gas butterfly valve High pressure supply (setting pressure in mbar into double solenoid valve) Nominal diameter of valve trains Nominal diameter of gas butterfly valve The combustion chamber pressure in mbar must be added to the minimum gas pressure For selection of valve trains for towns gas see separate worksheet Print No. 900. Pressure regulators to DIN 3380 with safety diaphragm are used for low pressure supply with double solenoid valves (DMV). Maximum permitted...

 Open the catalogue to page 13

Rating Low pressure supply (gas pressure kW in mbar into isolating valve, Pemax = 300 mbar) Nominal diameter of valve trains Nominal diameter of gas butterfly valve High pressure supply (setting pressure in mbar into double solenoid valve) Nominal diameter of valve trains Nominal diameter of gas butterfly valve The combustion chamber pressure in mbar must be added to the minimum gas pressure For selection of valve trains for towns gas see separate work sheet Print No. 900. Pressure regulators to Dl N 3380 with safety diaphragm are used for low pressure supply with double solenoid valves (DMV)....