Dual fuel burner sizes 30 to 70 vers NR - Weishaupt - #2

/ 28


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
P. 23
P. 24
P. 25
P. 26
P. 27
P. 28
Pages:


See other catalogues for Weishaupt

Text version of the page
2 Regulation Dependent on fuel, burner size and requirements, the regulation of air and fuel is by: • Two and three stage The oil side of dual fuel burners has a nozzle assemble with two or three nozzles. A change in firing rate is effected by opening and closing of solenoid valves 2 and 3 with the relevant air volume. • Sliding two stage For sliding two stage control, partial and full load are set positions within the regulation range. The burner’s firing rate slides between the two load points, depending on the heat demand. Thus there are no sudden large increases or decreases in the amount of fuel used. • Modulation Modulating burners operate at any point within the regulation range, depending on the heat demand. Reduced capacity at start-up The burners start at ignition load an additional pilot line. In this way only a small amount of gas flows into the combustion chamber. After a short delay the burner moves to partial load operation. Controlled shut downs from partial load Controlled shut down of the burner always takes place from the partial load position, thus preventing impact on the gas main. Fuel / air ratio The controlled mixing of fuel and combustion air varies depending on the size and type of burner: Size 30 Burner types RGL and RGMS: Pressure side air regulation via a compound regulated control sleeve in the mixing head. Burner type GL: Pressure side air regulation via an adjustable control sleeve in the mixing head for capacity adjustment. Sizes 40 to 70 Burner types GL, RGL and RGMS: Pressure side air regulation via a compound regulated control sleeve in the mixing head. Heavy oil burners Heavy oil burners are fitted with oil preheaters which control the oil temperature to keep it at the necessary viscosity for good atomisation. Before the burner starts, a temperature controlled sequence programme heats the nozzle to the same operating temperature by circulating preheated oil through the nozzle head. Valve trains To comply with EN 676 burners must be equipped with two solenoid valves. Weishaupt gas and dual fuel burners are equipped with two Class A solenoid valves (DMV) as standard. The W-FM 100 combustion manager provides for valve proving when an additional gas pressure switch is fitted. Other gas side accessories such as gas filters and gas pressure regulators, can be found in the List of Accessories. Digital combustion management The W-FM 100 and W-FM 200* combustion managers ensure the simple and safe operation of combustion plant. All important functions, such as fuel and air feed or flame monitoring are controlled with digital precision. The aim is the optimisation of operational functions, the maximisation of economy, and the minimisation of emissions. Thanks to digital combustion management such an optimisation is available today at limited cost. The outlay for installation and service is substantially lower than with conventional technologies. For example, a separate control panel for the burner switchgear is no longer necessary. Furthermore, remote operation, diagnosis and monitoring of the plant can be realised. That makes things safer and simpler for the operator. Applications The burners can be used with heat exchangers such as hot water boilers, steam boilers, air heaters, and for certain process applications. As the burners are capable of overcoming high combustion chamber resistances, they are used primarily on modern high rated boilers. Fuels Oil side (Fuel Oil DIN 51 603): Light fuel oil (EL) Viscosity 6 mm2/s at 20°C Medium and heavy fuel oil (S) Viscosity up to 50 mm2/s at 100°C Gas side (DVGW Worksheet G 260/l): Natural Gas E (formerly designated Natural Gas H) Natural Gas LL (formerly designated Natural Gas L). Liquid petroleum gas F Installation sites In standard execution (materials, construction, protection), the burners are suitable for use indoors at temperatures between -15°C and +40°C and with a maximum relative humidity of 80%. Certification The burners have been independently tested and comply with the following European standards and EC directives: • EN 267 / EN 676 • Machinery Directive 98/37/EC • Electromagnetic Compatibility Directive 89/336/EEC • Low Voltage Directive 73/23/EEC • Gas Appliance Directive 90/396/EEC • Pressure Vessel Directive 97/23/EC Outstanding service Weishaupt maintains an extensive global sales and service network. Customer service is available every day around the clock. In-house training by Weishaupt ensures the high standard of their service engineers. * Available early 2004 Description Weishaupt industrial burners, sizes 30 to 70, have been especially designed for industrial capacity ranges. The monobloc burners are noteworthy for their large capacity and operational ranges and numerous other interesting details: • Compliance with the most stringent directives and emission limits • Large capacity and operational ranges • Stable fan reference line - good combustion behaviour • Quiet operation • Burner housing can be hinged open • Easy to install, set and service • Automatic air shut off on burner shut down

pageCatalog pdf di En 2012-06-22-01