| | | Interface TOPLINE TE84 | | |
| | | |
| | | Assignment of the 25-pole DSUB interface socket X2 | | |
| | | |
| | | | | | | | | | | | PIN No. on DSUB SOCKET Interface X2 | Signal name | Module Number | Description | | | | 1 | FS1-24V | 1 | These inputs allow the generator modules to be controlled remotely via 24V switching voltage (PLC output / PIN-16 GND) | | | | 2 | FS2-24V | 2 | | | | 3 | FS3-24V | 3 | | | | 4 | FS4-24V | 4 | | | | 5 | FS5-24V | 5 | | | | 6 | FS6-24V | 6 | | | | 7 | +15V | Shared | +15V voltage supply / evaluation for users total I-max.100mA | | | | 8 | +15V | Shared | | | | 9 | NC | | Not connected | | | | 10 | POUT-1 | 1 | These outputs serve the external output control of the individual generator modules Range 5-10V (corresponds to 50-100% power) (optional 1-10V corresponds to 10-100%) | | | | 11 | POUT-2 | 2 | | | | 12 | POUT-3 | 3 | | | | 13 | POUT-4 | 4 | | | | 14 | POUT-5 | 5 | | | | 15 | POUT-6 | 6 | | | | 16 | GND | Shared | Ground | | | | 17 | GND | Shared | | | | 18 | NC | | Not connected | | | | 19 | NC | | | | | 20 | HF-DA1 | 1 | These outputs allow each generator module to be evaluated / (for example, as a supplement to error relays / "OK signal") Configurable as opener or closer (Voltageless - Root PIN 13/X1) | | | | 21 | HF-DA2 | 2 | | | | 22 | HF-DA3 | 3 | | | | 23 | HF-DA4 | 4 | | | | 24 | HF-DA5 | 5 | | | | 25 | HF-DA6 | 6 | | | | | | | | | | | |
| | | |
| | | 9 | | |
| | | |
| | | | | | | | | | | |